Title fBlock f- fCORRECT✅✅Identifies fthe fproject fin fa fdrawing.
Legend f- fCORRECT✅✅Information fneeded fto fidentify flines fand fother fsymbols fon fa
fconstruction fdrawing.
Break fLines f- fCORRECT✅✅Used fto fshow fthat fonly fpart fof fan fobject fis frepresented
fto fsave fspace.
Dimension f- fCORRECT✅✅A fmeasurement fwritten fas fa fnumber.
Scale fon fSite fPlan f- fCORRECT✅✅Indicates fthat fevery finch frepresents f20 ffeet.
Triangular fArchitect's fScale f- fCORRECT✅✅Most fcommonly fused fbecause fit fcan
fcombine fmultiple fscales.
Civil fPlans f- fCORRECT✅✅Plans fthat fshow fan faerial fview fof fthe fbuilding fsite
flocation.
Mechanical fPlans f- fCORRECT✅✅Engineered fplans ffor fmotors, fpumps, fpiping
fsystems, fand fpiping fequipment.
Outlet fBox fDepth fRequirement f- fCORRECT✅✅All foutlet fboxes fmust fhave fa
fminimum fdepth fof f2 f1/2 finches.
Conductor fCount fin fBox f- fCORRECT✅✅Total fconductor fcount fis f4 fwhen ffour fwires
fenter fa fbox fand fexit fagain.
Laundry fArea fReceptacles f- fCORRECT✅✅According fto fNEC fSection f210.52,
flaundry fareas frequire fat fleast fone freceptacle.
Conductors fDeduction ffor fReceptacle f- fCORRECT✅✅When fsizing fan foutlet fbox, f2
fconductors fmust fbe fdeducted ffor fa freceptacle.
Pull fBox fLength fRequirement f- fCORRECT✅✅For fa fstraight fpull, fthe flength fof fthe
fbox fmust fbe fno fless fthan feight ftimes fthe ftrade fdiameter fof fthe flargest fraceway.
Junction fBox fSize fRequirement f- fCORRECT✅✅Must fbe f32 finches fif fthere fis fone
f4" fconduit, fone f3" fconduit, fand fone f2" fconduit fentering fon fone fside.
Questions With Verified Answers
Title fBlock f- fCORRECT✅✅Identifies fthe fproject fin fa fdrawing.
Legend f- fCORRECT✅✅Information fneeded fto fidentify flines fand fother fsymbols fon fa
fconstruction fdrawing.
Break fLines f- fCORRECT✅✅Used fto fshow fthat fonly fpart fof fan fobject fis frepresented
fto fsave fspace.
Dimension f- fCORRECT✅✅A fmeasurement fwritten fas fa fnumber.
Scale fon fSite fPlan f- fCORRECT✅✅Indicates fthat fevery finch frepresents f20 ffeet.
Triangular fArchitect's fScale f- fCORRECT✅✅Most fcommonly fused fbecause fit fcan
fcombine fmultiple fscales.
Civil fPlans f- fCORRECT✅✅Plans fthat fshow fan faerial fview fof fthe fbuilding fsite
flocation.
Mechanical fPlans f- fCORRECT✅✅Engineered fplans ffor fmotors, fpumps, fpiping
fsystems, fand fpiping fequipment.
Outlet fBox fDepth fRequirement f- fCORRECT✅✅All foutlet fboxes fmust fhave fa
fminimum fdepth fof f2 f1/2 finches.
Conductor fCount fin fBox f- fCORRECT✅✅Total fconductor fcount fis f4 fwhen ffour fwires
fenter fa fbox fand fexit fagain.
Laundry fArea fReceptacles f- fCORRECT✅✅According fto fNEC fSection f210.52,
flaundry fareas frequire fat fleast fone freceptacle.
Conductors fDeduction ffor fReceptacle f- fCORRECT✅✅When fsizing fan foutlet fbox, f2
fconductors fmust fbe fdeducted ffor fa freceptacle.
Pull fBox fLength fRequirement f- fCORRECT✅✅For fa fstraight fpull, fthe flength fof fthe
fbox fmust fbe fno fless fthan feight ftimes fthe ftrade fdiameter fof fthe flargest fraceway.
Junction fBox fSize fRequirement f- fCORRECT✅✅Must fbe f32 finches fif fthere fis fone
f4" fconduit, fone f3" fconduit, fand fone f2" fconduit fentering fon fone fside.