100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

2025 IBHRE Exam Questions with Answers and Rationale

Puntuación
-
Vendido
-
Páginas
130
Grado
A+
Subido en
07-07-2025
Escrito en
2024/2025

2025 IBHRE Exam Questions with Answers and Rationale

Institución
2025 IBHRE
Grado
2025 IBHRE











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
2025 IBHRE
Grado
2025 IBHRE

Información del documento

Subido en
7 de julio de 2025
Número de páginas
130
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

2025 IBHRE Exam Questions with
Answers and Rationale
A function of pacemaker circuitry that allows the pacemaker output pulse to be dissipated
quickly maximizing both the output and sensing capabilities.



a) circuit resistors

b) charge dump

c) pulse neutralizer

d) current consumption ------- Correct Ans ---------- B. Charge Dump



AV sequentially paced patients with frequent ventricular ectopy should have the following
pacemaker parameters programmed to decrease the chance of competition:



a) short blanking period

b) slower base rate

c) increased ventricular refractory period

d) none of the above ------- Correct Ans ---------- A. Short Blanking Period



Low threshold electrode materials include each of the following EXCEPT:



a) iridium oxide

b) elgiloy

c) platinized platinum

d) titanium nitride ------- Correct Ans ---------- B. Elgiloy

,The strength duration curve resulting in a parabolic shape is described by which of the following
formulas?



a) I x t

b) I x V x t

c) I x R

d) all of the above ------- Correct Ans ---------- B. I x V x t



The ventriculoatrial conduction time of a pacemaker patient with a typical endless-loop-
tachycardia may be calculated by which equation?



a) (upper rate limit interval) - ( AV delay + PVARP)

b) (upper rate limit interval) - ( AV delay + PVARP + Wenckebach interval

c) (lower rate limit interval) - ( upper rate limit interval)

d) none of the above ------- Correct Ans ---------- D. None of the above



Which of the following programmings would not prevent crosstalk?



a) a prolonged blanking period

b) "safety pacing"

c) low atrial output

d) less sensitive ventricular sensitivity ------- Correct Ans ---------- B. "Safety Pacing"



The most commonly used battery chemistry in ICDs is:



a) lithium thionyl chloride

b) lithium manganese dioxide

,c) lithium silver vanadium oxide

d) lithium manganese dioxide ------- Correct Ans ---------- C. Lithium Silver Vanadium Oxide



The purpose of a capacitor in an electrical circuit is to:



a) convert AC to DC current

b) store electrical charge

c) rapidly switch battery voltage on or off

d) limit current flow to a single direction ------- Correct Ans ---------- B. Store Electrical Charge



A programming mode that would NOT be utilized to manage intermittent atrial fibrillation in a
patient with a DDD pacemaker is:.



a) DDI

b) DVI

c) VDD

d) VVI ------- Correct Ans ---------- C. VDD



Variations in stimulus morphology on the surface ECG of an analog recorder may be caused by:



a) a dislodged electrode

b) an electrical short

c) changes in patient position

d) all of the above ------- Correct Ans ---------- D. All of the above



All of the following have been used as ERI magnet responses except:

, a) abrupt increase in rate

b) abrupt decrease in rate

c) gradual increase in rate

d) gradual decrease in rate ------- Correct Ans ---------- C. Gradual Increase In Rate



Which of the following has not been used as an indicator of battery depletion?



a) pulse width stretching

b) mode change

c) programmed amplitude reversion

d) telemetered battery impedance ------- Correct Ans ---------- C. Programmed Amplitude
Reversion



The electrical circuit that converts a signal with both positive and negative components into a
signal with only one component?



a) resistor

b) rectifier

c) diode

d) capacitor ------- Correct Ans ---------- B. Rectifier



Which of the following would account for the most common cause of inappropriate mode
switching?



a) ventricular lead sensing atrial signals

b) lead insulation break
$27.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
irungugrace513

Conoce al vendedor

Seller avatar
irungugrace513 Walden University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
0
Miembro desde
5 meses
Número de seguidores
0
Documentos
45
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes