– Versions A & B Practice Exams |
Verified Answers & Rationale | A+
Graded
Version A (50 Questions)
Question 1
What is a primary responsibility of a Firefighter II during a structural fire?
A. Assume incident command
B. Perform assigned tasks and assist with coordination
C. Direct traffic at the scene
D. Supervise all operations
Correct Answer: B
Rationale: NFPA 1001 (2019) specifies that Firefighter II performs assigned tasks under
supervision and assists with coordination, such as team leadership, unlike assuming command
(A), directing traffic (C), or supervising all operations (D).
Question 2
Which NFPA standard governs Firefighter II professional qualifications?
A. NFPA 472
B. NFPA 1001
C. NFPA 1582
D. NFPA 1970
Correct Answer: B
Rationale: NFPA 1001 outlines professional qualifications for Firefighter I and II, including
advanced skills for Firefighter II. NFPA 472 (A) covers hazmat, NFPA 1582 (C) addresses
medical programs, and NFPA 1970 (D) focuses on PPE.
Question 3
When ventilating a pitched roof, what should a firefighter avoid?
A. Cutting near natural openings
B. Cutting through joists or trusses
C. Using a power saw
D. Opening the ceiling below
,Correct Answer: B
Rationale: Cutting through joists or trusses compromises structural integrity, increasing collapse
risk. Natural openings (A), power saws (C), and opening ceilings (D) are part of safe ventilation.
Question 4
What is a key advantage of the flat hose load?
A. Requires fewer personnel
B. Ideal for large-diameter hose
C. Prevents all hose kinks
D. Simplifies shoulder carries
Correct Answer: B
Rationale: The flat load is effective for large-diameter hose, ensuring efficient deployment. It
doesn’t guarantee fewer personnel (A), kink prevention (C), or simplified shoulder carries (D).
Question 5
What is the first action after opening a roof during ventilation?
A. Direct a hose line into the opening
B. Ensure the ceiling below is opened
C. Make another opening on the opposite side
D. Remove natural roof openings
Correct Answer: B
Rationale: Opening the ceiling below ensures effective smoke and heat release, per NFPA 1001
ventilation protocols. Hose lines (A), additional openings (C), or removing natural openings (D)
are secondary.
Question 6
Which fire company is responsible for forcible entry?
A. Engine company
B. Brush company
C. Truck company
D. Special rescue company
Correct Answer: C
Rationale: Truck companies handle forcible entry, ventilation, and ladder operations, per NFPA
1001. Engine companies (A) focus on fire suppression, brush companies (B) on wildland fires,
and rescue companies (D) on specialized rescues.
Question 7
What is a common cause of multiple firefighter deaths at incidents?
A. Incidents in urban settings only
B. Lack of an effective command structure
C. All incidents involving forest fires
D. Industrial complex fires only
, Correct Answer: B
Rationale: A lack of an organized command structure often leads to chaos and fatalities, per
NFPA 1001 and incident reviews. Other options (A, C, D) are not universally applicable.
Question 8
Which fire burn stage is characterized by maximum heat release?
A. Initial
B. Rollover
C. Fully developed
D. Backdraft
Correct Answer: C
Rationale: The fully developed stage involves peak heat and fire intensity, per IFSTA Essentials.
Initial (A) is early growth, rollover (B) involves flame spread, and backdraft (D) is an explosive
event.
Question 9
What is true about personal protective equipment (PPE) under NFPA 1970?
A. Prevents burns in flashover situations
B. Requires PASS activation at all times
C. Must be appropriate for the hazard faced
D. Complies with NFPA 1900 standard
Correct Answer: C
Rationale: NFPA 1970 (effective 2024) requires PPE to match the hazard. It doesn’t prevent
flashover burns (A), require constant PASS activation (B), or align with NFPA 1900 (D).,
Question 10
What does the risk management model assume about saving lives?
A. Firefighters risk nothing for lives
B. Firefighters risk a lot to save savable lives
C. Firefighters never risk their lives
D. Firefighters risk lives only in urban fires
Correct Answer: B
Rationale: NFPA 1001’s risk management model prioritizes risking a lot to save savable lives,
balancing safety and duty. Other options (A, C, D) misalign with this principle.
Question 11
What is the correct action for power tools not marked double insulated?
A. Use a two-prong plug
B. Use a three-prong plug
C. Never use outside
D. Avoid extension cords
Correct Answer: B