Florida LP Gas & Rules
Study online at https://quizlet.com/_ezwlu9
1. Licensed Locations Qualifier:
A) Full Time Employee
B) Non-Supervisory Position
C) Multiple Locations
D) All of the Above: A) Full Time Employee
2. Vacancies in Qualifier must be reported:
A) By the qualifier
B) By the licensed company
C) 20 Working Days
D) 60 Working Days
E) All of the above: E) All of the above
3. Is the Bureau of Compliance is currently responsible for licensing, exams
and training.
A) True
B) False: A) True
4. Qualifier means any business who has passed a competency examination
administrated by the department and is employed by a licensed Cat I, II, V
business.
A) True
B) False: B) False
Qualifier means any Person who has passed a competency examination adminis-
trated by the department and is employed by a licensed Cat I, II, V business.
5. The Department may impose civil or administrative penalties in the Class II
category, for each offense, suspend or revoke the license.
A) Not to exceed $1,300
B) Exceed $3,000
C) Not to exceed $2,000
D) Not to exceed $3,000: D) Not to exceed $3,000
6. Qualifier automatically expires if you terminate active employment in the
area of examination for a period
A) Exceeding 24 days
B) Exceeding 30 months
C) Exceeding 24 months
D) Exceeding 24 days: C) Exceeding 24 months
7. A cylinder exchange unit must have what signage affixed to the front of the
unit and all approachable sides:
A) Propane
B) Flammable Gas
, Florida LP Gas & Rules
Study online at https://quizlet.com/_ezwlu9
C) No Smoking
D) All of the Above: D) All of the Above
8. Documentation shall be maintained at the employee's place of business and
shall be available for inspection by the department upon request.
A) True
B) False: A) True
9. Pressure relief devices installed in underground dispensing tanks shall be
piped vertically upward of feet above the ground.
A) 11
B) 10
C) 12
D) 9: B) 10
10. No person under the age of years shall be permitted to dispense
propane.
A) 20
B) 21
C) 19
D) None of the Above: D) None of the Above
Age of 18 years
11. Which Category License can requalify cylinders?
A) Cat I
B) Cat 2
C) Cat 3
D) Cat 4: A) Cat 1
12. A person, firm, or corporation who disconnects any container or system
shall notify the owner of the container or system within hours.
A) 1
B) 12
C) 24
D) 48: C) 24
13. Vehicle fuel dispensers or dispensing stations which have been inactive
( out of service) for a period of months shall be removed from the
premises.
A) 10
B) 11
C) 12
D) 24: C) 12 months
14. According to what NFPA 54 Annex can you find the methods for leak test
as incorporated by reference in rule 5J-20.002, F.A.C?
, Florida LP Gas & Rules
Study online at https://quizlet.com/_ezwlu9
A) Annex B
B) Annex C
C) Annex L
D) None of the Above: B) Annex C of the NFPA 54
15. When must you the appropriate Weights & Measures Permit?
A) A Truck Meter (>20 gpml)
B) A Dispenser Meter (<20 gpml)
C) Scale for weighting
D) All of the Above: D) All of the Above
16. Outside training (PTS, others) courses must be approved by the Depart-
ment.
A) True
B) False: A) True
17. Who is primarily responsible for the overseeing the operations of the
licensed location?
A) Master Qualifier
B) Qualifier
C) Owner
D) Either A or C: A) Master Qualifier
MQ can be a owner but a owner might not be a MQ
18. Does Florida allow tanks to be on RV or structure roofs?
A) True
B) False: False
19. Requalifiers of cylinders must have a Cat 1 license.
A) True
B) False: A) True
20. Proof of insurance primary policy must cover
A) Loss of Income
B) Property Damage Liability
C) Bodily Injury Liability
D) Both B and C: D) Both B and C
Must not be less than $1 min coverage
21. NFPA 58 Section 4.4 requires every employee who handles or causes
propane to be transported to have refresher training
A) Every three years.
B) Every two years.
C) Every six months.
D) Every year.: A) Every three years.
Study online at https://quizlet.com/_ezwlu9
1. Licensed Locations Qualifier:
A) Full Time Employee
B) Non-Supervisory Position
C) Multiple Locations
D) All of the Above: A) Full Time Employee
2. Vacancies in Qualifier must be reported:
A) By the qualifier
B) By the licensed company
C) 20 Working Days
D) 60 Working Days
E) All of the above: E) All of the above
3. Is the Bureau of Compliance is currently responsible for licensing, exams
and training.
A) True
B) False: A) True
4. Qualifier means any business who has passed a competency examination
administrated by the department and is employed by a licensed Cat I, II, V
business.
A) True
B) False: B) False
Qualifier means any Person who has passed a competency examination adminis-
trated by the department and is employed by a licensed Cat I, II, V business.
5. The Department may impose civil or administrative penalties in the Class II
category, for each offense, suspend or revoke the license.
A) Not to exceed $1,300
B) Exceed $3,000
C) Not to exceed $2,000
D) Not to exceed $3,000: D) Not to exceed $3,000
6. Qualifier automatically expires if you terminate active employment in the
area of examination for a period
A) Exceeding 24 days
B) Exceeding 30 months
C) Exceeding 24 months
D) Exceeding 24 days: C) Exceeding 24 months
7. A cylinder exchange unit must have what signage affixed to the front of the
unit and all approachable sides:
A) Propane
B) Flammable Gas
, Florida LP Gas & Rules
Study online at https://quizlet.com/_ezwlu9
C) No Smoking
D) All of the Above: D) All of the Above
8. Documentation shall be maintained at the employee's place of business and
shall be available for inspection by the department upon request.
A) True
B) False: A) True
9. Pressure relief devices installed in underground dispensing tanks shall be
piped vertically upward of feet above the ground.
A) 11
B) 10
C) 12
D) 9: B) 10
10. No person under the age of years shall be permitted to dispense
propane.
A) 20
B) 21
C) 19
D) None of the Above: D) None of the Above
Age of 18 years
11. Which Category License can requalify cylinders?
A) Cat I
B) Cat 2
C) Cat 3
D) Cat 4: A) Cat 1
12. A person, firm, or corporation who disconnects any container or system
shall notify the owner of the container or system within hours.
A) 1
B) 12
C) 24
D) 48: C) 24
13. Vehicle fuel dispensers or dispensing stations which have been inactive
( out of service) for a period of months shall be removed from the
premises.
A) 10
B) 11
C) 12
D) 24: C) 12 months
14. According to what NFPA 54 Annex can you find the methods for leak test
as incorporated by reference in rule 5J-20.002, F.A.C?
, Florida LP Gas & Rules
Study online at https://quizlet.com/_ezwlu9
A) Annex B
B) Annex C
C) Annex L
D) None of the Above: B) Annex C of the NFPA 54
15. When must you the appropriate Weights & Measures Permit?
A) A Truck Meter (>20 gpml)
B) A Dispenser Meter (<20 gpml)
C) Scale for weighting
D) All of the Above: D) All of the Above
16. Outside training (PTS, others) courses must be approved by the Depart-
ment.
A) True
B) False: A) True
17. Who is primarily responsible for the overseeing the operations of the
licensed location?
A) Master Qualifier
B) Qualifier
C) Owner
D) Either A or C: A) Master Qualifier
MQ can be a owner but a owner might not be a MQ
18. Does Florida allow tanks to be on RV or structure roofs?
A) True
B) False: False
19. Requalifiers of cylinders must have a Cat 1 license.
A) True
B) False: A) True
20. Proof of insurance primary policy must cover
A) Loss of Income
B) Property Damage Liability
C) Bodily Injury Liability
D) Both B and C: D) Both B and C
Must not be less than $1 min coverage
21. NFPA 58 Section 4.4 requires every employee who handles or causes
propane to be transported to have refresher training
A) Every three years.
B) Every two years.
C) Every six months.
D) Every year.: A) Every three years.