3RD CLASS STATIONARY STEAM ENGINEER LICENSE PREP EXAM QUESTIONS AND ANSWERS _________ are necessary for complete combustion - CORRECT ANSWERtime, temperature, mixture, and atomization

Vista previa del contenido

3RD CLASS STATIONARY STEAM ENGINEER LICENSE PREP
EXAM QUESTIONS AND ANSWERS
_________ are necessary for complete combustion - CORRECT ANSWER✅✅✅time, temperature,
mixture, and atomization



if the steam pressure gauge indicates 200 PSIG, the absolute pressure is______ - CORRECT
ANSWER✅✅✅214.7



a boiler is operating at 400 PSI, and the safety valve opens at 410 PSI and closes at 398 PSI. The
blowdown is______psi - CORRECT ANSWER✅✅✅12



an oil cooler is commonly used with a(n) ________ when operating in conjunction with a turbo-
generator - CORRECT ANSWER✅✅✅steam turbine



a boiler is producing 40,000lb of steam/hr at a pressure of 100 PSI and a steam temperature of 500
degrees Fahrenheit. The steam produced is _______ steam - CORRECT ANSWER✅✅✅superheated



the economizer on a boiler is used to _______ - CORRECT ANSWER✅✅✅add heat to the feed water



blowers are normally used with________ boilers - CORRECT ANSWER✅✅✅water tube



overheating of tubes on a boiler can be caused by________ - CORRECT ANSWER✅✅✅scale on tubes



carbon dioxide in a condensate return system causes_________ - CORRECT
ANSWER✅✅✅channeling



a ________ pump is a positive displacement pump - CORRECT ANSWER✅✅✅reciprocating



a boiler generating 6000 lb of steam/hr produces _______btu/hr - CORRECT
ANSWER✅✅✅6,000,000

,a bottom blowdown is performed on a boiler to _____ - CORRECT ANSWER✅✅✅discharge sludge
and sediment



water columns are connected to the boiler with a minimum of _______" pipe - CORRECT
ANSWER✅✅✅1



the minimum size of a water column blowdown valve is_______". - CORRECT ANSWER✅✅✅3/4



the maximum size bottom blowdown valve on a boiler is_________". - CORRECT ANSWER✅✅✅2
1/2



a ________ allows condensate to pass through, but stops Steam. - CORRECT ANSWER✅✅✅a steam
trap



when taking over a shift, the first thing to do is check the________ - CORRECT ANSWER✅✅✅water
level in each boiler



according to the asme code, a high-pressure boiler having more than 500 square feet of heating surface
shall have________ - CORRECT ANSWER✅✅✅two or more safety valves



the probable cause of an increase in temperature of gases of combustion at the boiler Outlet is____ -
CORRECT ANSWER✅✅✅dirty heating services



boilers in battery equipped with________ must have two main steam stop valves and a free-flowing
drain between them - CORRECT ANSWER✅✅✅manhole openings



in order to be sure the gauge glass is indicating an accurate water level reading, the stationary engineer
should______ - CORRECT ANSWER✅✅✅blowdown the gauge glass



a continuous blowdown line is located___ - CORRECT ANSWER✅✅✅in the Steam and water drum
well below the nowl

, a temperature reading of 80 degrees Celsius is equal to_________°f - CORRECT ANSWER✅✅✅176



a chimney temperature of 250 degrees Fahrenheit above steam temperature indicates_______ -
CORRECT ANSWER✅✅✅poor efficiency



a manometer is red in________ - CORRECT ANSWER✅✅✅inches of water



the boiling point of water will____ with an increase in pressure - CORRECT ANSWER✅✅✅be raised



if a lather is not obtained when performing a soap hardness test, the water sample is_______ - CORRECT
ANSWER✅✅✅hard



combustion efficiency can be increased when air is________ - CORRECT ANSWER✅✅✅preheated



______ draft is produced by a fan located between the boiler and the chimney - CORRECT
ANSWER✅✅✅induced



the overspeed trip on a steam turbine should be tested ______ - CORRECT ANSWER✅✅✅before
putting the steam turbine on-line



a high CO2 reading in the gases of combustion is a sign of____ - CORRECT ANSWER✅✅✅High
combustion efficiency



the purpose of chemically treating feedwater is to________ - CORRECT ANSWER✅✅✅turn scale-
forming salts to a non adhering sludge



water in a d rating feed water heater is prevented from entering the steam line by a(n) _______. -
CORRECT ANSWER✅✅✅Loop seal or internal overflow

Información del documento

Subido en
13 de junio de 2025
Número de páginas
23
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$11.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
STANGRADES
3.4
(14)
Vendido
92
Seguidores
1
Artículos
12010
Última venta
1 semana hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes