CORRECT ANSWERS
The end of the temperature sensing portion of the temperature measuring device is submerged
in a minimum of _____ mm [_____ in.] into the freshly mixed concrete. - correct answers ✔✔75
mm [3 in]
The temperature measuring device shall be capable of accurately measuring the temperature of
freshly mixed concrete to +/- _____ °C [+/- _____ °F] throughout a range of _____ °C [_____ °F].
- correct answers ✔✔0.5 °C [1 °F], 0 °C to 50 °C [30 °F to 120 °F]
The temperature measuring device shall be verified _____, or whenever there is a question of
_____. - correct answers ✔✔annually, accuracy
The temperature of concrete may be measured in a wheelbarrow. True or false? - correct
answers ✔✔True
The temperature of concrete may be measured in a wall form. True or false? - correct answers
✔✔True
A composite sample of concrete is required even if the only purpose for obtaining the sample is
to determine temperature. True of false? - correct answers ✔✔False
What must be done to the sample container prior to sampling the concrete? - correct answers
✔✔Dampen (with water)