100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

ARDMS Fetal Echocardiography Questions with Correct Answers 2025/2026

Puntuación
-
Vendido
-
Páginas
19
Grado
A+
Subido en
04-06-2025
Escrito en
2024/2025

ARDMS Fetal Echocardiography Questions with Correct Answers 2025/2026

Institución
Cardio
Grado
Cardio










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Cardio
Grado
Cardio

Información del documento

Subido en
4 de junio de 2025
Número de páginas
19
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ARDMS Fetal Echocardiography Questions
with Correct Answers 2025/2026

What is the incidence of Ebstein's anomaly? - CORRECT ANSWER -1%



What chromosomal anomalies are associated with Ebstein's? - CORRECT ANSWER -Trisomy 13,
18, and 21



What arrhythmia is associated with Ebstein's anomaly? - CORRECT ANSWER -SVT



What other 2 things are commonly associated with Ebstein's? - CORRECT ANSWER -
Cardiomegaly and hydrops



What other cardiac anomalies are frequently seen with Ebstein's? - CORRECT ANSWER -ASD,
PS/PA, VSD, TOF, subaortic AS, COA



What is the typical cardiac position in Ebstein's anomaly? - CORRECT ANSWER -Severe
levocardia



What is the best echo view to diagnose Ebstein's? - CORRECT ANSWER -4 Chamber view



What leaflet of the tricupisd valve is described as "sail like" with Ebstein's anomaly? - CORRECT
ANSWER -The anterior leaflet



What maternal drug has been associated with Ebstein's anomaly? - CORRECT ANSWER -Lithium



What value is an increased CT ratio? - CORRECT ANSWER ->0.45

,What rate is persistent fetal tachycardia? - CORRECT ANSWER ->180 bpm



What rate is persistent fetal bradycardia? - CORRECT ANSWER -<120 bpm



When is a fetal echocardiogram commonly performed? - CORRECT ANSWER -18-22 weeks
gestational age



What is a normal fetal heart rate? - CORRECT ANSWER -120-180 bpm



What should the equipment settings be for the equipment for a fetal echo? - CORRECT ANSWER
-High color PRF and Doppler, low persistance



temporal resolution - CORRECT ANSWER -ability to accurately locate moving structures at any
particular instant in time



What are the factors that affect temporal resolution? - CORRECT ANSWER -frequency, depth
and focus, sector angle, zoom magnification



The chromosome abnormality that carries the highest risk of an associated cardiac defect is: -
CORRECT ANSWER -Edwards Syndrome



A normal E/A ratio of the mitral or tricuspid valve in the fetus is: - CORRECT ANSWER -<1



The most common fetal cardiac abnormality associated with maternal infection is: - CORRECT
ANSWER -cardiomyopathy

, The most common fetal cardiac abnormality associated with maternal lupus erythematosus is: -
CORRECT ANSWER -complete heart block



Most congenital diaphragmatic hernias are of which type? - CORRECT ANSWER -Bochdalek



On ultrasonography, a type III cystic adenomatoid malformation will appear: - CORRECT
ANSWER -hyperechoic



bronchopulmonary sequestration can be confirmed with ultrasonography by identifying a(n): -
CORRECT ANSWER -anomalous feeding artery



Patau Syndrome - CORRECT ANSWER -Trisomy 13



Edwards syndrome - CORRECT ANSWER -Trisomy 18



What percentage of isolated atrial septal defects will close spontaneously after birth? -
CORRECT ANSWER -60%



What type of ASD is caused by excessive resorption of the septum primum? - CORRECT ANSWER
-ostium secundum



AVSD associated with complete heart block are most commonly associated with: - CORRECT
ANSWER -asplenia



Which maternal condition has a strong association with AVSD? - CORRECT ANSWER -Diabetes



If a woman has a history of an AVSD, her offspring has a ___ percent change of having an AVSD -
CORRECT ANSWER -14%
$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
AcademicACHIEVER oxford university
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
275
Miembro desde
1 año
Número de seguidores
17
Documentos
8944
Última venta
21 horas hace
A+ Academic achiever

On this page, you find all documents, package deals, and flashcards offered by seller Academic achiever

3.2

61 reseñas

5
21
4
8
3
11
2
3
1
18

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes