100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

Latest Texas Ext Type B TFM02 questions and updated answers

Puntuación
-
Vendido
-
Páginas
7
Grado
A+
Subido en
03-06-2025
Escrito en
2024/2025

Latest Texas Ext Type B TFM02 questions and updated answers

Institución
Texas Ext Type B TFM02
Grado
Texas Ext Type B TFM02









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Texas Ext Type B TFM02
Grado
Texas Ext Type B TFM02

Información del documento

Subido en
3 de junio de 2025
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Latest Texas Ext Type B TFM02 questions and updated answers


6 yrs - ANSWER-dry chem extinguishers requiring 12 yr hydrostatic test must be
emptied for maintenance procedures every

A rated UL extinguishers = how many gallons of water? - ANSWER-1.25

C - ANSWER-Class ____ fire extinguishers use electrically nonconductive extinguishing
agents

Every 5 years - ANSWER-Cartridge operated water based portable extinguishers need
hydrostatic testing

A three dimensional fire often involves static flammable liquid. true or false - ANSWER-
false. 3D firess unvolve flammable liquid in motion as well as both horizontal and
vertical surfaces.

Class A fire extinguisher - ANSWER-are ok for wood, paper, some plastics and textiles.
They offer the coating effects of dry chemicals.

Dry chemical stored pressure fire extinguishers: - ANSWER-should be removed or
replaced at their next 6 year maintenance or hydrostatic test interval.

B:C - ANSWER-Talking about UL rating, the _____ rating refers to the amount of sq
footage an extinguisher covers

Class B fire extinguishers cannot handle flammable liquid - ANSWER-False

employees must be trained in proper use of all portable fire extinguishers according to -
ANSWER-CRF29

monthly - ANSWER-you need to have portable fire extinguishers VISUALLY inspected
at least _____ according to 29 CFR 1910.157 (e) (2)

Class A/B fire extinguishers - ANSWER-should NOT be used forfire that involves live
electrical equipment

annually - ANSWER-Water or steam fire extinguishers need to be discharged,
dissassembled and inspected at least:

3.5 ft - ANSWER-An extinguisher weighing over 40 lbs should be installed so the top is
no more than __ from the ground

, 50 ft. - ANSWER-OSHA specified maximum travel distance to an extinguisher for Class
B


stored pressure type extinguishers need need INTERNAL examination : - ANSWER-
never

5 ft above the ground - ANSWER-extinguishers weighing 40 lbs or less must be
installed so top of canister is no more than _____

K - ANSWER-class ___ extinguishers are for fires involving cooking media

75 ft - ANSWER-OSHA specified max travel distance for Class A is ______

C - ANSWER-proper UL rating to use on electrically energized equipped

Class K - ANSWER-work on the principle of saponification

Obstacle Type Fires - ANSWER-involve flammable liquid on a horizontal surface w/ the
presence of a solid object creating a barrier

4 inches - ANSWER-extinguishers must be installed at least _____ from the ground

Obstacle Type Fires - ANSWER-may take place in flammable liquid storage caninets,
dip tank process areas, etc.

Must Be Weighed - ANSWER-To make sure the pressure gauges of CO2 extinguisher
are showing adequate pressure, what must you do?

5 yrs - ANSWER-Wetting agent portable extinguishers must be hydrostatic tested every
_____

After recharge - ANSWER-leak tests on stored pressure extinguishers must be
performed

cannot - ANSWER-how do u convert fire extinguishers from 1 type to another?

any remaining dry chemical in a discharged extinguisher - ANSWER-may be reused
only if checked for proper type, contamination, and condition. closed recovery system
needs to be used!

New extinguishers needing charge in the field - ANSWER-do not need to have any
verification of service collar installed

you cannot - ANSWER-how do u have an extinguisher converted to use a different type
of extinguishing agent
$21.89
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BESTPDF Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
30
Miembro desde
2 año
Número de seguidores
13
Documentos
1123
Última venta
3 meses hace

3.0

5 reseñas

5
2
4
0
3
1
2
0
1
2

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes