ACTUAL Exam Questions and CORRECT
Answers
A major disadvantage of a floor standing pump extinguisher over a backpack extinguisher is: -
CORRECT ANSWER - Pumping must stop to relocate the floor standing pump
All maintenance on portable fire extinguishers must be: - CORRECT ANSWER -
Contracted out to a certified service company
(4-039-1.1) Overheating of electrical equipment is: - CORRECT ANSWER - Is one of the
conditions that usually cause electrical fires in buildings
(4-031-2.7) When isolating an electric motor driven pump, you should first: - CORRECT
ANSWER - Open the motor breaker
It is the employers responsibility to ____________ personal protective equipment . - CORRECT
ANSWER - Supply and ensure usage of
What tool is used to find hazards in a plant? - CORRECT ANSWER - A Hazard
Assessment and Identification process
(4-026-1.2) A Material Safety Data Sheet must be supplied by the: - CORRECT
ANSWER - Supplier of the controlled product
(4-038-1.6) Which of the following extinguishers would ordinarily be used to combat a Class
"C" fire: - CORRECT ANSWER - Carbon dioxide and Dry chemical
(4-032-1.1) By definition in this chapter, a "confined space" is any enclosed or partially enclosed
space having: - CORRECT ANSWER - Restricted access and egress and may become a
life-threatening environment.
, The type of standpipe system that requires a supplemental detection system to operate is the: -
CORRECT ANSWER - Preaction
(4-037-2.4) Which of the following extinguishers would ordinarily be used to combat a Class
"C" fire: - CORRECT ANSWER - Carbon dioxide
An area in which easily ignited material fibers are handled or manufactured has an Electrical
Designation of: - CORRECT ANSWER - Class 3
(4-033-4.1) The valve cap on a gas cylinder: - CORRECT ANSWER - Protects the
cylinder valve from damage.
(4-032-1.4) Confined space entry procedures should be applied when work is being done in any
industrial area that does not have: - CORRECT ANSWER - Easy access for personnel
rescue in an emergency
(4-038-1.1) Foam extinguishers are recommended for: - CORRECT ANSWER - Class "A"
and Class "B" fires
Every day sprinkler checks should include: - CORRECT ANSWER - Visual inspection of
fire hoses for readiness
(4-034-1.8) Fuel air mixtures that are outside of the flammable range: - CORRECT
ANSWER - Cannot burn or explode
(4-037-2.12) Halon agents extinguish a fire by: - CORRECT ANSWER - Breaking the
molecular chain reactions
(4-029-2.2) A high proportion of the reported workplace injuries are from the age group of: -
CORRECT ANSWER - 16 to 25