Radiography Final Exam/ Radiography Practice Questions and Answers
2025|100% Pass|
Which of the following modes of a trifield image intensifier will result in the highest patient dose? A.
Its 25-in. mode
B. Its 17-in. mode
C. Its 12-in. mode
D. Diameter does not affect patient dose

Its 12-in. mode

A particular AP thoracic measurement is 25 cm. What tomographic sections are indicated if we desire
one midline and one each anterior and posterior to midline?
A. 8, 9, and 10 cm
B. 10, 11, and 12 cm
C. 12, 13, and 14 cm
D. 14, 15, and 16 cm

12, 13, and 14 cm

T/F: The cooling oil in an x-ray tube is part of the inherent filtration

TRUE

When using the smaller field in a dual-field image intensifier, 1.
a smaller patient area is viewed.
2. the image is magnified.
3. the image is less bright.

AOTA

Design characteristics of x-ray tube targets that determine heat capacity include the
1 rotation of the anode
2 diameter of the anode
3 size of the focal spot

AOTA

A technique chart should be prepared for each AEC x-ray unit and should contain which of the following
information for each type of examination?
1 Photocell(s) used
2 Optimum kilovoltage
3 Backup time

AOTA

Which of the following statements regarding dual x-ray absorptiometry is (are) true?
1 It is a low-dose procedure.
2 Two x-ray photon energies are used.

,3 Photon attenuation by bone is calculated.

AOTA

Disadvantages of moving grids over stationary grids include which of the following?
1 They can prohibit the use of very short exposure times.
2 They increase patient radiation dose.
3 They can cause phantom images when anatomic parts parallel their motion.

1 and 2 ONLY

How is the thickness of the tomographic section related to the tomographic angle? A.
The greater the tomographic angle, the thicker the section.
B. The greater the tomographic angle, the thinner the section.
C. The less the tomographic angle, the thinner the section.
D. The tomographic angle is unrelated to section thickness.

The greater the tomographic angle, the thinner the section.

All the following x-ray circuit devices are located between the incoming power supply and the primary
coil of the high-voltage transformer except
A. the timer
B. the kilovoltage meter
C. the milliamperage meter D. the autotransformer the milliamperage meter

Which of the following techniques is used to evaluate the dynamics of a part?
A. Fluoroscopy
B. Stereoscopy
C. Tomography
D. Phototiming

Fluoroscopy

In which of the following examinations would a cassette front with very low absorption properties be
especially important? A. Abdominal radiography
B. Extremity radiography
C. Angiography
D. Mammography

Mammography

The ability of an x-ray unit to produce constant radiation output, at a given mA, using various
combinations of mAs and time is called
A. linearity.
B. reproducibility.
C. densitometry.
D. sensitometry.

linearity

,Advantages of battery-powered mobile x-ray units include their
1 ability to store a large quantity of energy
2 ability to store energy for extended periods of time 3 lightness and ease of
maneuverability

1 and 2 ONLY

Star and wye configurations are related to
A. autotransformers
B. three-phase transformers
C. rectification systems D. AECs three-phase transformers

When the radiographer selects kilovoltage on the control panel, which device is adjusted?
A. Step-up transformer
B. Autotransformer
C. Filament circuit
D. Rectifier circuit

Autotransformer

The total brightness gain of an image intensifier is the product of
1 flux gain
2 minification gain 3 focusing gain

1 and 2 ONLY

Which of the following is used in digital fluoroscopy, replacing the image intensifier's television camera
tube?
A. Solid-state diode
B. Charge-coupled device
C. Photostimulable phosphor
D. Vidicon

Charge-coupled device

Which of the following devices is used to control voltage by varying resistance?
A. Autotransformer
B. High-voltage transformer
C. Rheostat
D. Fuse

Rheostat

Which of the following equipment is mandatory for performance of a myelogram?
A. Cine camera
B. 105-mm spot film
C. Tilting x-ray table
D. Tomography

, Tilting x-ray table

Which of the following devices is (are) component(s) of a typical fluoroscopic video display system? 1
Videotape recorder
2 TV camera
3 TV monitor

2 and 3

The x-ray tube in a CT imaging system is most likely to be associated with
A. low-energy photons
B. an unrestricted x-ray beam
C. a pulsed x-ray beam D. a large focal spot a pulsed x-ray beam

Accurate operation of the AEC device depends on
1 the thickness and density of the object
2 positioning of the object with respect to the photocell 3 beam restriction

2 and 3 ONLY

Which of the following would be appropriate cassette front material(s)?
1 Tungsten
2 Magnesium
3 Bakelite

2 and 3 ONLY

The image intensifier's input phosphor generally is composed of
A. cesium iodide
B. zinc cadmium sulfide
C. gadolinium oxysulfide D. calcium tungstate cesium iodide
In fluoroscopy, the automatic brightness control is used to adjust the
A. kilovoltage (kVp) and milliamperage (mA)
B. backup timer
C. milliamperage (mA) and time D. kilovoltage (kV) and time kilovoltage (kVp) and milliamperage (mA)

The most commonly used types of AEC devices are the 1.
ion chamber.
2. photomultiplier tube.
3. cathode ray tube.

1 and 2 ONLY

Dedicated radiographic units are available for 1.
chest radiography.
2. head radiography.
3. mammography.

AOTA

Escuela, estudio y materia

Grado

Información del documento

Subido en
29 de mayo de 2025
Número de páginas
130
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$25.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
DrTOPNOTCH Chamberlain College Of Nursng
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
31
Miembro desde
2 año
Número de seguidores
14
Documentos
663
Última venta
1 mes hace
TOPNOTCH SERVICES| PASS YOUR EXAMS WITH EASE|EXCELLENT ASSIGNMENT HELP AND TUTORING

Welcome to your one-stop shop for top-quality nursing resources. I offer a wide range of up-to-date -nursing exams, - test banks, - study guides -NCLEX prep materials, -NGN exams etc. This will help you study smarter and score higher. Whether you're a nursing student or prepping for your boards, you'll find exactly what you need here. Start browsing and take the stress out of exam season.

4.5

4 reseñas

5
2
4
2
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes