E1 RESIDENTIAL ELECTRICAL INSPECTOR 2025/2026
QUESTIONS WITH ANSWERS TAGGED A+
✔✔True or False. Snap switches that are rated for 20 amperes or less and directly
connected to aluminum conductors must be marked CO/ALR. - ✔✔True

Section E4001.2

✔✔Receptacles located more than ___ feet above the floor are NOT required to be
tamper resistant. - ✔✔5.5

Section E4002.14 Exception #1

✔✔True or False. Metal faceplates for receptacles are NOT required to be grounded. -
✔✔False

Section E4002.4

✔✔Cord-suspended luminaires shall not be located within an area measured ___ feet
horizontally and ___ feet vertically from the top of a bathtub or shower stall threshold. -
✔✔3, 8

Section E4003.11

✔✔Luminaires that weigh more than ___ pounds shall NOT be supported by the screw
shell of a lampholder. - ✔✔6

Section E4004.4

✔✔True or False. A branch-circuit overcurrent device is allowed to be used as a
disconnecting means for permanently connected appliances rated not over 300 volt-
amperes. - ✔✔True

Section E4101.5, Table E4101.5

✔✔A flexible cord for a cord-and-plug connected trash compactor must have a
minimum cord length of ____ and maximum length of ____ inches. - ✔✔36, 48

Section E4101.3, Table E4101.3

✔✔Appliances and equipment shall be installed in accordance with which of the
following? - ✔✔Manufacturer's installation instructions

Section E4101.2

, ✔✔A ___ ampere-rated receptacle outlet servicing heating, air-conditioning and
refrigeration equipment must be installed at an accessible location. - ✔✔15 & 20

Section E3901.12

✔✔A receptacle outlet servicing heating, air-conditioning and refrigeration equipment
must be located on the same level and within ____ feet from the equipment. - ✔✔25

Section E3901.12

✔✔Receptacles located within ___ feet from the inside wall of a swimming pool must be
protected by a ground-fault circuit-interrupter. - ✔✔20

Section E4203.1.3

✔✔At least one receptacle must be located between ___ feet and ___ feet from the
inside wall of an indoor spa and hot tub. - ✔✔6, 10

Section E4203.1.4

✔✔Underground wiring installed in a rigid metal conduit and located within 5 feet
horizontally from the inside wall of a swimming pool shall have a minimum burial depth
of ___ inches. - ✔✔6

Section E4203.7, Table E4203.7

✔✔At least one receptacle outlet shall be installed at hallways having a length of ___
feet or more. - ✔✔10

Section E3901.10

✔✔Receptacle outlets shall have ground-fault circuit-interrupter protection when
installed at which of the following locations? (Bathrooms, garages, outdoors, all of the
above) - ✔✔All of the above

Section E3902.1, E3902.2, E3902.3

✔✔True or False. Receptacle outlets are allowed to be installed in a face-up position at
kitchen countertops and work surfaces. - ✔✔False

Section E3902.7

Información del documento

Subido en
27 de mayo de 2025
Número de páginas
9
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BOARDWALK
3.5
(40)
Vendido
278
Seguidores
10
Artículos
32861
Última venta
3 días hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes