100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Masonry ICC study With Full Solution /Verified Grade A+

Puntuación
-
Vendido
-
Páginas
12
Grado
A+
Subido en
25-05-2025
Escrito en
2024/2025

Masonry ICC study With Full Solution /Verified Grade A+

Institución
Masonry ICC Study
Grado
Masonry ICC study









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Masonry ICC study
Grado
Masonry ICC study

Información del documento

Subido en
25 de mayo de 2025
Número de páginas
12
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Masonry ICC study With Full Solution
/Verified Grade A+

Control joints are considered joints that will ..... shortening, shrinkage and/or reduction in the length of the
V V V V V V V V V V V V V V V V




wall.
V




A. Coordinate
V V




B. Accommodate
V V




C. Reduce
V V




D. Control - Answer B. Accommodate
V V V V V




A standard hook can be a 180° turn plus an extension of at least ..... bar diameters, but not less than .....
V V V V V V V V V V V V V V V V V V V V V




inches at the free end of the bar
V V V V V V V V




A. 4,2.25
V V




B. 4,2.5V V




C. 2.2.75
V V




D. 2,3 - Answer B. 4bar diameters or 2.5 inches
V V V V V V V V V




The cleanout opening at the bottom of a masonry wall is a minimum of .....
V V V V V V V V V V V V V V




A. 3 inches in any direction
V V V V V V




B. 4 inches by 4 inches
V V V V V




C. 32 inches
V V




D. 2 inches in any direction - Answer A. 3" in any direction
V V V V V V V V V V V V




The minimum length of saw-cut prisms shall be ..... inches
V V V V V V V V V




A. 8 V V




B. 6 V




C. 4 V




D. 2 - Answer C. 4 inches
V V V V V V




Movements can occur from a number of sources, such as .... V V V V V V V V V V




A. Ground settlement
V V V




B. Material expansion and contraction
V V V V V




C. Seismic activity
V V V




D. All of the above - Answer D. All of the above
V V V V V V V V V V V




The compressive strength of grout in concrete masonry construction is recommended to be at least ..... to
V V V V V V V V V V V V V V V V




..... times the design strength of the masonry assembly
V V V V V V V V V




A. 1.00 to 1.25
V V V

, B. 1.25 to 1.33
V V V




C. 1.33 to 1.45
V V V




D. 1.45 to 1.60 - Answer B 1.25 to 1.33
V V V V V V V V V




The minimum clearance required between reinforcing steel and the CMU in a grouted cell using course
V V V V V V V V V V V V V V V




grout is .....
V V V




A. 1 bar diameters
V V V




B. 1/4 inch
V V




C. 1/2 inch
V V




D. 1 inch - Answer C. 1/2 inch
V V V V V V V




The maximum grout pour using the high lift grouting method for a clear cell area of 3 inches by 3 inches is
V V V V V V V V V V V V V V V V V V V V V




.....
V




A. 5 feet
V V




B. 8 feet using course grout
V V V V V




C. 12 feet
V V




D. 24 feet using fine grout - Answer D. 24 feet using fine grout
V V V V V V V V V V V V V




When the air temp is 25°F, requirements shall include .....
V V V V V V V V V




A. Heating the cement
V V V




B. Maintaining mortar on board above freezing
V V V V V V V




C. Heating sand above 120°F
V V V V




D. Heating water above 120°F - Answer B. Maintaining mortar temp
V V V V V V V V V V




In a low lift grout pour, the grouting is stopped approximately ..... below the top of the masonry unit.
V V V V V V V V V V V V V V V V V V




A. 1/2 inch
V V




B. 1 inch
V V




C. 1-1/2 inches
V V




D. 2 inches - Answer C. 1-1/2 inches
V V V V V V V




For course grout, the maximum total aggregate measured in a damp loose condition shall be ..... times the
V V V V V V V V V V V V V V V V V




sum of the volume of the cementitious material.
V V V V V V V V




A. 3V




B. 3.25
V




C. 4.25
V




D. 5 - Answer D. 5 times the sum
V V V V V V V V




When the mean daily air temp is between 25°F and 40°F, the masonry shall be protected by covering with a
V V V V V V V V V V V V V V V V V V V




weather-resistive membrane for ..... hours.
V V V V V




A. 12 hours
V V




B. 24 hours
V V




C. 36 hours
V V
$14.19
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Lectjay Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
26
Miembro desde
11 meses
Número de seguidores
1
Documentos
340
Última venta
2 semanas hace
LIGHT

Updated exams Actual tests 100% And verified.Here, you will find everything you need ALL EXAMS Are guaranteed success.

4.0

6 reseñas

5
4
4
0
3
1
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes