100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Oil Burners license test QUESTIONS AND ANSWERS

Puntuación
-
Vendido
-
Páginas
5
Grado
A+
Subido en
19-05-2025
Escrito en
2024/2025

Oil Burners license test QUESTIONS AND ANSWERSOil Burners license test QUESTIONS AND ANSWERSOil Burners license test QUESTIONS AND ANSWERSOil Burners license test QUESTIONS AND ANSWERSOil Burners license test QUESTIONS AND ANSWERSOil Burners license test QUESTIONS AND ANSWERSOil Burners license test QUESTIONS AND ANSWERSOil Burners license test QUESTIONS AND ANSWERSOil Burners license test QUESTIONS AND ANSWERSOil Burners license test QUESTIONS AND ANSWERSOil Burners license test QUESTIONS AND ANSWERS

Mostrar más Leer menos
Institución
Oil Burners License
Grado
Oil Burners license









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Oil Burners license
Grado
Oil Burners license

Información del documento

Subido en
19 de mayo de 2025
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Oil Burners license test QUESTIONS
AND ANSWERS

The main function of the primary control is: - CORRECT ANSWER-Locking out on
safety in the event of flame failure

Power must be provided to an electric blower control board on terminals: - CORRECT
ANSWER-L1 and L2

Once a PSC motor starts - CORRECT ANSWER-The centrifugal switch turns off the
electricity to the capacitor and the start windings

Materials who's electrons are so loosely bound that they can be persuaded to move with
very little pressure allowing electricity to flow are called - CORRECT ANSWER-
Conductors

Oil burners can make CO even when no smoke is present - CORRECT ANSWER-True

Corrosion in the flu pipe may occur if - CORRECT ANSWER-Flue gas temperature is
below the dewpoint and sulfur oxide's combine with water

To avoid condensing and the flu pipe and oil fired appliance should have a minimum
growth stock temperature of - CORRECT ANSWER-350°F

All persons assisting and working under the supervision of a person holding a certificate
as an oil burner technician must hold current apprentice certificates issued by
Department of fire services - CORRECT ANSWER-True

What size pipe is used to cross connect tank outlets piping - CORRECT ANSWER-1/2
inch

Fuel return piping from an appliance shall - CORRECT ANSWER-Enter the top of the
tank

Delayed ignition may be caused by - CORRECT ANSWER-Unvented pressure
regulator

Installation of oil safety valves and oil pressure reducing valve - CORRECT ANSWER-
Reduces the chance of a return line leak

, What is an installation - CORRECT ANSWER-Complete and ready for operation of any
oil burning appliance

Energizing the ignition circuit during the entire burn cycle reduces - CORRECT
ANSWER-Ignition component life

Fuel can be transferred from a tank to an appliance by pressurizing the tank -
CORRECT ANSWER-False

What device must be equipped with an air proving switch - CORRECT ANSWER-Both,
draft inducers and power-venters

What is a safety control - CORRECT ANSWER-Any control used to prevent unsafe
operation of the controlled equipment

A non-resident steam or hot water boiler having a minimum safety relief valve capacity
over 200,000 BTU/hr requires certificate of inspection from the department of fire
services - CORRECT ANSWER-Prior to the initial firing, every 3 years after

What is the closest distance a supply tank can be to the burner - CORRECT ANSWER-
5 feet

Doing a combustion pretest on and oil burning appliance will not tell you anything this is
why they generally are performed - CORRECT ANSWER-False

What is the minimum oil supply line size for a residential system - CORRECT
ANSWER-3/8 inch

A cad cell primary control can lock out safety because - CORRECT ANSWER-All of the
above- dirty, faulty, not sensing flame

As heating oil gets colder it's viscosity thickens: - CORRECT ANSWER-Increase

The purpose of the oil burner nozzle is to: - CORRECT ANSWER-Atomize, pattern and
meter the oil

The primary control must be capable of - CORRECT ANSWER-All of the above

A decrease in CO2 with an increase in excess air will give a drop in stack temperature -
CORRECT ANSWER-True

Minimum net stack temperature of above 350°F must be maintained - CORRECT
ANSWER-To avoid condensation and maintain draft

The primary control must be capable of reacting to - CORRECT ANSWER-The
presence or absence of flame
$19.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
Proffscholar4

Conoce al vendedor

Seller avatar
Proffscholar4 stuvia
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
0
Miembro desde
8 meses
Número de seguidores
0
Documentos
109
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes