E-30.13.1 All power cables shall be_____ against chafe and physical
damage by installation in conduit, dedicated cable trays, or by cable
clamps or other secure methods which meet the requirements of
ABYC E-11, AC and DC Electrical Systems on Boats. - ----
Answers_---protected
E-30.13.2 High current conductors for the propulsion system shall not
be______ in the same wiring system as the vessel's AC or DC
circuits, unless one of the following methods of separation is used: - --
--Answers_---contained
E-30.13.2 High current conductors for the propulsion system shall not
be contained in the same wiring system as the vessel's AC or DC
circuits, unless one of the following methods of separation is used: E-
30.13.2.1 installed in a physically________ conduit or cable tray or, -
----Answers_---separate
E-30.13.2 High current conductors for the propulsion system shall not
be contained in the same wiring system as the vessel's AC or DC
circuits, unless one of the following methods of separation is used: E-
30.13.2.2 installed on a tray or ladder where physical separation is
provided by a________, or - ----Answers_---partition
E-30.13.2 High current conductors for the propulsion system shall not
be contained in the same wiring system as the vessel's AC or DC
circuits, unless one of the following methods of separation is used: E-
,30.13.2.3 fixed directly to the surface and separated by at least _
inches (100mm). - ----Answers_---4
E-30.13.3 Dedicated motor inverter/controller power conductors,
between the inverter/controller and motor shall be designed and
installed to minimize conducted or radiated electromagnetic______. -
----Answers_---emissions
E-30.13.4 All connections, other than to batteries and circuits under
60 VDC, shall be made in __________ enclosures or the connections
themselves shall be fire resistant. - ----Answers_---self-extinguishing
E-30.13.5 Self-limited power supplies shall be________ with a
maximum current output available. For power supplies not so labeled,
see ABYC E-11, AC and DC Electrical Systems on Boats for required
circuit protection requirements. - ----Answers_---labeled
E-30.13.6 Conductors should be permanently identified within at least
_ inches (152.5 mm) of the end of the conductor as to voltage and
purpose (see ABYC E-11.) - ----Answers_---6
E-30.13.7 All panelboards and switchboards should be protected as
follows: LOCATION IP ENCLOSURE RATING, Interior __ - ----
Answers_---N/A
E-30.13.7 All panelboards and switchboards should be protected as
follows: LOCATION IP ENCLOSURE RATING, Machinery___ - ---
-Answers_---IP55
,E-30.13.7 All panelboards and switchboards should be protected as
follows: LOCATION IP ENCLOSURE RATING, Wet____ - ----
Answers_---IP56
E-30.13.7 All panelboards and switchboards should be protected as
follows: LOCATION IP ENCLOSURE RATING, Damp____ - ----
Answers_---IP44
E-30.13.8 All conductors shall meet the requirements of: E-30.13.8.1
_____, National Electric Code, or - ----Answers_---NFPA 70
E-30.13.8 All conductors shall meet the requirements of: E-
30.I3.8.2_______, High Voltage Primary Cable, or - ----Answers_---
SAE J 1654
E-30.13.8 All conductors shall meet the requirements of: E-30.13.8.3
________, Electrical Installations in Ships - Part 353: Power cables
for rated voltages 1 kV and 3 kV, or - ----Answers_---IEC 60092.353
E-30.13.8 All conductors shall meet the requirements of: E-30.13.8.4
I________, Recommended Practice for Electric Installations on
Shipboard. - ----Answers_---EEE 45
E-30.13.9 Conductor sizes shall be selected from TABLE 1, or
according to the equipment ___________ specifications. - ----
Answers_---manufacturer's
, E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1 _______ data
including: - ----Answers_---Battery group
E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1.1 _________ - ----
Answers_---battery technology/type
E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1.2 prospective
___________ in amperes - ----Answers_---short circuit current
E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1.3 ________ and
temperature requirements - ----Answers_---ventilation
E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1.3 ventilation and
_______ requirements - ----Answers_---temperature
E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1.4 ________ - ----
Answers_---amp hours
E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.2 ________ data
including: - ----Answers_---Generator