100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

EKG CERTIFICATION TEST EXAM WITH CORRECT ANSWERS 2025

Puntuación
-
Vendido
-
Páginas
23
Grado
A+
Subido en
16-05-2025
Escrito en
2024/2025

EKG CERTIFICATION TEST EXAM WITH CORRECT ANSWERS 2025

Institución
EKG CERTIFICATIO
Grado
EKG CERTIFICATIO










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
EKG CERTIFICATIO
Grado
EKG CERTIFICATIO

Información del documento

Subido en
16 de mayo de 2025
Número de páginas
23
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

EKG CERTIFICATION TEST EXAM WITH
CORRECT ANSWERS
1. 2025of time for the QRS
What is the approximate amount
0.04-0.10
complex to record on an ECG
2. Identify the measures of the intervals in the PRI:
strip be- low 0.14
QRS:
0.08
QT:
0.28




3. What is a typical characteristic of a Premature Two P waves for
Atrial Contraction (PAC) one QRS
complex
4. What is a major complication of atrial Thrombi
fibrillation formation
5. A three-month-old patient is fussy and Smooth the child
moving his arms and legs. What should the with a pacifier and
ECG technician do in order to get proper alow the par- ent to
electrode placement for an accurate EGC? hold the child

6. Where should the V4 electrode be placed on the body? left
midclavicular line, 5th
intercostal space

7. Which condition requires the lead placement shown
Dextrocardia
in the diagram below?



8 PR
. Interval
1/
23

,EKG CERTIFICATION TEST EXAM WITH
CORRECT ANSWERS
To determine the quality of 2025
atrial activity on an
ECG strip, the ECG technician should examine
which of the following portions of the cardiac
cycle?

9. An ECG technician is preparing to perform an ECG on Put both the
right and left a patient with a total left arm amputation. How should
on the torso, below the the technician place the arm electrodes?
clavicle

10. Prior to an ECG a patient informs the ECG technician Position the
patient in the that he often experiences orthopnea. How should the
semi-Fowler's position technician prepare this patient for the ECG
procedure?

11. If the RA-LA sensors are reversed on a patient, the ECG Lead 1
will record a downward deflection in

12. What is the minimum number of variations of the P 3
wave in a wandering atrial pacemaker rhythm?

13. What should an ECG technician do to correct wave sets Increase
14. A female
the patient has come in for an ECG
running As close to the
following a mastectomy.
that are too ECG
close together electrodes
to be surgery
accurately analyzed? speedsite
of theas
ECG machine
should be placed possible without
to 50mm/sec
touch- ing the site
15. Which of the following are true of the ECG Decreased cardiac
rhythm shown in the strip below output occurs with
duration.
Seriousness
depends on
the length of the
pause. It is a
normal sinus rhythm
2/
23 with a blocked
PAC.

,EKG CERTIFICATION TEST EXAM WITH
CORRECT ANSWERS
2025
16. What variation in ECG results is likely for patients with Presence of a
pacing spike
pacemakers? `

17. What is the rhythm shown in the strip below Ventricular
pacing




18. Improper grounding of the ECG during set-up is most Alternating
Current Artifact
likely to result in

19. A cardiac cycle is detected on the ECG monitor, but the PEA
(Pulseless Electrical
20. When
patienta has
patient with aThis
no pulse. pacemaker
is knownhas
as an Small Activity)
spikes
ECG per- formed, the strip will contain where a P wave
may not be seen
21. While performing a stress test on a patient, the patient
Notifythephysician/nurse complains of chest pain and has the ECG
shown below. and stop the treadmill Which of the following should
the ECG technician do
next?

22. A constant PRI that exceeds 0.20 seconds indicates A first degree
23. AV After
block validation an ECG order, collection all Identify the
supplies, and ensuring the machine is in proper patient
working order, the technician's next action
should be to
24. An ECG technician records and ECG on a 37- Continue with the
year-old patient and obtains the strip shown proce- dure as
below. What ac- normal
3/
23
$18.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
HopeJewels Axia University Of Phoenix
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
69
Miembro desde
1 año
Número de seguidores
10
Documentos
8608
Última venta
3 semanas hace
macellen education agencies

On this page, you find all documents,testsbank ,solution manuals, package deals, On this page, you find all documents, package deals, and flashcards offered by seller Hopejewels

3.2

5 reseñas

5
2
4
0
3
1
2
1
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes