Name the 3 Spaulding Classification Systems -Correct Answer Critical Semi-Critical Non-Critical Meaning of Critical Spaulding Classification System -Correct Answer Items MUST be sterile. Items will enter -sterile tissue- or -vascular system- Examples of items in Critical Spaulding Classification System -Correct Answer -Instruments- -Laparoscopes- -Arthroscopes- -*Cutting endoscope accessories for biopsy*- -Cardiac Caths- -IV caths- - Needles- -*Urinary Caths- Meaning of Semi-Critical Spaulding Classification System -Correct Answer Items SHOULD be sterile. Items will contact -broken skin- or -MM- If the manufacturers instructions say it WON'T tolerate sterilization, they CAN be HLD (but only IF MF SAYS). -Spores survive HLD- Examples of items in Semi-Critical Spaulding Classification System -Correct Answer -Bronchoscopes -GI Scopes/GI endoscopes -RT equipment (laryngoscope blades) -Anesthesia equipment Meaning of Non Critical Spaulding Classification System -Correct Answer -Will be in contact with INTACT SKIN -Intermediate or Low Level Disinfection or Cleaning. -Disinfect with an FDA approved disinfectant that's effective against HEP B. Examples of items in Non Critical Spaulding Classification System -Correct Answer -Furniture -Laundry/Linens -OR bed -BP Cuff/Leads/Monitors/Stethoscopes -Tourniquets Requirement for decontamination area: -Correct Answer -Must have a physical WALL or SEPARATION between decontam and processing areas. -This includes Immediate Use Areas. -Why: Because decontam requires NEGATIVE PRESSURE Sterile Processing Workflow -Correct Answer Decontamination (always 1st) -- Prep&Pack --Sterilization --Distribute/Store Most important step to prevent infection: -Correct Answer Cleaning and Pre-treating with a non-drying enzymatic solution in order to avoid biofilm, which encapsulates spores. Decontamination processes -Correct Answer -Disassemble everything -Brush lumens/channels using a brush based on mfr instruction for correct diameter and length of lumen -Brush lumens/channels/crevices/joints UNDER WATER -Automated (washers/ultrasonic) more effective than manual cleaning. Two Types of Steam Sterilization -Correct Answer -Pre-Vac Autoclave/Dynamic Air Removal -Gravity Displacement PreVac settings -Correct Answer 270-276 3 min (NON porous instruments/regular instruments) 4 min (POROUS or LUMEN instruments, heavy plastic, rubber, wooden handles, poole suction) PreVac/Dynamic Air Removal setting for porous (heavy plastic, rubber, wood handels) or lumen instruments (poole suction/channels) -Correct Answer 270-276 for 4 min PreVac/Dynamic Air Removal setting for Non Porous instruments -Correct Answer 270-276 for 3 min How does PreVac/Dynamic Air Removal autoclave work? -Correct Answer -Sucks air out of chamber with a VACCUM then steam is released and snaps down onto inst/trays. -DRAINS MUST BE CLEAN -Most common. Most effective. Gravity Displacement Autoclave settings -Correct Answer 270-276 3 min: NonPorous/reg instruments 10 min: Porous/Lumens Gravity Displacement autoclave settings for porous/lumens -Correct Answer min Gravity Displacement autoclave settings for NonPorous/reg inst -Correct Answer 270-276 3 min How does Gravity Displacement autoclave work? -Correct Answer Steam pushes air down to a thermometer in the drain, the air exits the chamber, drain closes, cycle starts. -Not great for trays or packages. -Rarely used. Both PreVac/Dynamic Air Removal and Gravity time and temperature requirements are for the instrument and autoclave only. For certain containers/systems such as One Tray system or containers with lids: -Correct Answer I will follow the manufacturers instructions! 3 ways to avoid condensation with steam sterilization items: -Correct Answer - Allow airflow between trays and pkgs and all the way around. -Remove loads immediately (don't crack the door to cool). -Don't place items on cooling racks or solid surfaces (can place on lined surfaces). How many classes of Chemical Integrators? -Correct Answer 6 What kind of chemical integrators react to heat? -Correct Answer Class 1 Chemical Indicator -Reacts to HEAT only. Verifies exposure only. -Tape-Locks-Filter dots What kind of chemical integrator is an External Indicator? -Correct Answer Class 1 Chemical Indicator External Indicator that reacts to Heat only -Tape-Locks-Filter dots What class of Chemical Indicator is the Bowie Dick, and what does it react to? -Correct Answer -Class 2 Chemical Indicator -Reacts to PRESSURE and ONLY indicates a VACUUM was created. -Used only with PreVac/Dynamic Air Removal cycles What class of chemical indicator measures

Mostrar más Leer menos
Institución
CNOR.
Grado
CNOR.

Vista previa del contenido

CNOR



CNOR 2024 Zander Notes Study Guide
Graded A+ UPDATED 2025
Name the 3 Spaulding Classification Systems -Correct Answer ✔Critical
Semi-Critical
Non-Critical

Meaning of Critical Spaulding Classification System -Correct Answer ✔Items MUST be
sterile.
Items will enter -sterile tissue- or -vascular system-

Examples of items in Critical Spaulding Classification System -Correct Answer ✔-
Instruments-
-Laparoscopes- -Arthroscopes-
-*Cutting endoscope accessories for biopsy*-
-Cardiac Caths-
-IV caths- - Needles-
-*Urinary Caths-

Meaning of Semi-Critical Spaulding Classification System -Correct Answer ✔Items
SHOULD be sterile.
Items will contact -broken skin- or -MM-

If the manufacturers instructions say it WON'T tolerate sterilization, they CAN be HLD
(but only IF MF SAYS).
-Spores survive HLD-

Examples of items in Semi-Critical Spaulding Classification System -Correct Answer ✔-
Bronchoscopes
-GI Scopes/GI endoscopes
-RT equipment (laryngoscope blades)
-Anesthesia equipment

Meaning of Non Critical Spaulding Classification System -Correct Answer ✔-Will be in
contact with INTACT SKIN
-Intermediate or Low Level Disinfection or Cleaning.
-Disinfect with an FDA approved disinfectant that's effective against HEP B.

Examples of items in Non Critical Spaulding Classification System -Correct Answer ✔-
Furniture
-Laundry/Linens
-OR bed
-BP Cuff/Leads/Monitors/Stethoscopes


CNOR

,CNOR


-Tourniquets

Requirement for decontamination area: -Correct Answer ✔-Must have a physical WALL
or SEPARATION between decontam and processing areas.
-This includes Immediate Use Areas.
-Why: Because decontam requires NEGATIVE PRESSURE

Sterile Processing Workflow -Correct Answer ✔Decontamination (always 1st) -->
Prep&Pack -->Sterilization
-->Distribute/Store

Most important step to prevent infection: -Correct Answer ✔Cleaning and Pre-treating
with a non-drying enzymatic solution in order to avoid biofilm, which encapsulates
spores.

Decontamination processes -Correct Answer ✔-Disassemble everything
-Brush lumens/channels using a brush based on mfr instruction for correct diameter and
length of lumen
-Brush lumens/channels/crevices/joints UNDER WATER
-Automated (washers/ultrasonic) more effective than manual cleaning.

Two Types of Steam Sterilization -Correct Answer ✔-Pre-Vac Autoclave/Dynamic Air
Removal
-Gravity Displacement

PreVac settings -Correct Answer ✔270-276

3 min (NON porous instruments/regular instruments)

4 min (POROUS or LUMEN instruments, heavy plastic, rubber, wooden handles, poole
suction)

PreVac/Dynamic Air Removal setting for porous (heavy plastic, rubber, wood handels)
or lumen instruments (poole suction/channels) -Correct Answer ✔270-276 for 4 min

PreVac/Dynamic Air Removal setting for Non Porous instruments -Correct Answer
✔270-276 for 3 min

How does PreVac/Dynamic Air Removal autoclave work? -Correct Answer ✔-Sucks air
out of chamber with a VACCUM then steam is released and snaps down onto inst/trays.
-DRAINS MUST BE CLEAN
-Most common. Most effective.

Gravity Displacement Autoclave settings -Correct Answer ✔270-276



CNOR

,CNOR


3 min: NonPorous/reg instruments

10 min: Porous/Lumens

Gravity Displacement autoclave settings for porous/lumens -Correct Answer ✔270-276
10 min

Gravity Displacement autoclave settings for NonPorous/reg inst -Correct Answer ✔270-
276 3 min

How does Gravity Displacement autoclave work? -Correct Answer ✔Steam pushes air
down to a thermometer in the drain, the air exits the chamber, drain closes, cycle starts.

-Not great for trays or packages.

-Rarely used.

Both PreVac/Dynamic Air Removal and Gravity time and temperature requirements are
for the instrument and autoclave only.
For certain containers/systems such as One Tray system or containers with lids: -
Correct Answer ✔I will follow the manufacturers instructions!

3 ways to avoid condensation with steam sterilization items: -Correct Answer ✔- Allow
airflow between trays and pkgs and all the way around.
-Remove loads immediately (don't crack the door to cool).
-Don't place items on cooling racks or solid surfaces (can place on lined surfaces).

How many classes of Chemical Integrators? -Correct Answer ✔6

What kind of chemical integrators react to heat? -Correct Answer ✔Class 1 Chemical
Indicator
-Reacts to HEAT only. Verifies exposure only.
-Tape-Locks-Filter dots

What kind of chemical integrator is an External Indicator? -Correct Answer ✔Class 1
Chemical Indicator
External Indicator that reacts to Heat only
-Tape-Locks-Filter dots

What class of Chemical Indicator is the Bowie Dick, and what does it react to? -Correct
Answer ✔-Class 2 Chemical Indicator
-Reacts to PRESSURE and ONLY indicates a VACUUM was created.
-Used only with PreVac/Dynamic Air Removal cycles

What class of chemical indicator measures


CNOR

, CNOR


-Single Parameter?
-Multi Parameter? -Correct Answer ✔-Class 3 Single (Ex: quality of steam)
-Class 4 Multi (Ex: Time+Temp)

-Class 3&4 are usually made by the manufacturer.

Which class of chemical indicator is the most common all inclusive integrator? -Correct
Answer ✔Class 5 Chemical Integrator/Indicator is the
-most common
-covers ALL parameters (time/temp/pressure/steam quality)
-ALL INCLUSIVE
-internal
-placed on each layer and in corner (most challenging area)
-used for implants

Which chemical indicator is used for implants? -Correct Answer ✔Class 5 Integrator

Which class of chemical indicator is used for a particular tray/cycle? -Correct Answer
✔Class 6 Emulating Integrator
-internal
-all inclusive for a SPECIFIC cycle
-made by mfr for a specific cycle OR tray

What does -integrator- mean? -Correct Answer ✔ALL inclusive. ALL parameters have
been met.
-Class 5 + Class 6

-No indicator or integrator promises sterility

Immediate Use settings:
What makes it different? -Correct Answer ✔270 10 min + BIO + Class 5 integrator

-Uses a rigid sterilization container with a lid.
-Must do same decontam process.
-Immediate Use has a shorter dry time.
-Items can be WET and it's OK
-NEVER use linens/wraps/packages in Immed Use

What has to be done for ALL steam sterilizers (PreVac/Dynamic, Gravity, IUS) -Correct
Answer ✔-Daily QCs with BIOLOGICALS to check for spores.
-Keep a sterilization log.

What happens if a steam sterilizer QC Bio fails? -Correct Answer ✔- Resterilize the
instruments



CNOR

Escuela, estudio y materia

Institución
CNOR.
Grado
CNOR.

Información del documento

Subido en
16 de mayo de 2025
Número de páginas
61
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$17.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
PossibleA Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1053
Miembro desde
5 año
Número de seguidores
650
Documentos
13787
Última venta
5 días hace
POSSIBLEA QUALITY UPDATED EXAMS

Choose quality study materials for nursing schools to ensure success in your studies and future career. "Welcome to PossibleA - your perfect study assistant! Here you will find Quality sheets, study materials, exams, quizzes, tests, and notes to prepare for exams and study successfully. Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers and checked for quality. Our quality sheets are an easy and quick way to remember key points and definitions. And our study materials, tests, and quizzes will help you absorb the material and prepare for exams. Our store also has notes and lecture summaries that will help you save time and make the learning process more efficient.

Lee mas Leer menos
3.9

149 reseñas

5
77
4
25
3
23
2
1
1
23

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes