100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

TCFP DRIVER OPERATOR MASTERCLASS EXAM WITH CORRECT ANSWERS 2025

Puntuación
-
Vendido
-
Páginas
77
Grado
A+
Subido en
12-05-2025
Escrito en
2024/2025

TCFP DRIVER OPERATOR MASTERCLASS EXAM WITH CORRECT ANSWERS 2025

Institución
TCFP DRIVER OPERATOR MASTERCLASS
Grado
TCFP DRIVER OPERATOR MASTERCLASS











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
TCFP DRIVER OPERATOR MASTERCLASS
Grado
TCFP DRIVER OPERATOR MASTERCLASS

Información del documento

Subido en
12 de mayo de 2025
Número de páginas
77
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

TCFP DRIVER OPERATOR
MASTERCLASS EXAM WITH
CORRECT ANSWERS 2025
1. What is the atmospheric pressure at sea level?
A. 3.1417 psi (22 kPa)
B. 7.69 psi (53 kPa)
C. 14.7 psi (101 kPa)
D.21.3 psi (147 kPa) ( correct
answers ) answer: C NFPA 1002:
10.2.1, 10.2.1(A)
Page: 324

2. What liquid is used to measure vacuum due
to its density?
A. 2-propanol
B. Glycerol
C. Water
D.Mercury ( correct answers )
answer: D NFPA 1002: 10.2.1,
10.2.1(A)
Page: 324

3. A fire pumper in good condition
should be able to develop a vacuum
equal to about:
A. 17 inches (391.4 mm Hg).
B. 22 inches (507.8 mm Hg).
C. 27 inches (623.2 mm Hg).
D.30 inches (692.4 mm Hg). ( correct answers )
answer: B NFPA 1002: 10.2.1, 10.2.1(A)
Page: 324

4.What term refers to the height that a column of water can be lifted
in a quantity considered sufficient to provide reliable fire flow?
A. Positive lift
B. Atmospheric lift
C. Dependable lift
D.Acceptable lift ( correct answers )
answer: C NFPA 1002: 10.2.1, 10.2.1(A)
Page: 325

5.Which term refers to the process of removing air from a fire pump
and replacing it with water?
A. Intake
GRADED
B.
A+ Rotary
C. Venturi
D. Priming ( correct answers ) answer: D

,NFPA 1002: 10.2.1, 10.2.1(A)
Page: 325

6. What is the best way to assess the operational readiness of the priming
system?
A. Perform a vacuum test
B. Perform a pump test
C. Perform a sprinkler test
D.Perform a hydrant test ( correct
answers ) answer: A NFPA 1002:
10.2.1, 10.2.1(A)
Page: 328

7.When a reliable public or private water system is not available,
drafting operations, relay pumping, water shuttles, and nurse tender
operations will become the responsibility of the:
A. tanker officer.
B. pumping officer.
C. water supply officer.
D.drafting officer. ( correct answers )
answer: C NFPA 1002: 10.2.1, 10.2.1(A)
Page: 330

8. What does the "C" stand for in the formula
Q=L × W × D × C?
A. Coefficient
B. Calculation
C. Constant
D.Coefficient calculation ( correct answers )
answer: C NFPA 1002: 10.2.1, 10.2.1(A)
Page: 331

10.Using the formula Q =W × D × V × C, calculate the amount of
water available in a stream that is 10 ft (3.05 m) wide and 2 ft (0.61 m)
deep. The water is traveling at 15 ft/min (4.57 m/min).
D. 2650 gpm
A. 2250 gpm (8520
(10,031
L/min) ( correct answers )
L/min)
B. 2350 gpm (8896 L/min) answer: A
NFPA
C. 24501002:
gpm10.2.1,
(9275 L/min)
10.2.1(A)
Page:
9.Using
331 the formula Q L × W × D × C, calculate the amount of water
available in a pond that is 100 ft (30.48 m) long, 80 ft (24.38 m) wide, and 4
ft (1.22 m) deep.
A. 24,000 gallons (90,850 L)
B. 240,000 gallons (908,500 L)
C. 2,400,000 gallons (9,085,000 L)
D.240,240 gallons (909,400 L) ( correct
answers ) answer: B NFPA 1002:
10.2.1, 10.2.1(A)
GRADED
A+

,Page: XX

11.What term refers to the vertical distance from the water level to the
center of the fire pumper?
A. Suction
B. Lift
C. Draft
D.Suspension ( correct answers )
answer: B NFPA 1002: 10.2.1, 10.2.1(A)
Page: 333

12.The first step in establishing a drafting
operation is to:
A. place the pump in gear.
B. locate an appropriate water source.
D. assemble
C. inspect thethe hard suction
gaskets hosesuction.
in the hard and ( correct answers )
strainer. NFPA 1002: 10.2.1, 10.2.1(A) answer: B
Page: 335

13.Which type of strainer is used for deep water sources in which the
driver/operator is confident the strainer will not contact the bottom of the
water source?
A. Floating strainer
B. Pipe strainer
C. Barrel strainer
D.Low-level strainer ( correct
answers ) answer: C NFPA 1002:
10.2.1, 10.2.1(A), 10.2.2, 10.2.2(A)
Page: 335

14.Which type of strainer is used for clean,
shallow water sources?
A. Floating strainer
B. Pipe strainer
C. Barrel strainer
D.Low-level strainer ( correct
answers ) answer: D NFPA 1002:
10.2.1, 10.2.1(A), 10.2.2, 10.2.2(A)
Page: 335

15.Which type of strainer is designed to operate below the surface scum
and above the weeds, dirt, and silt in the water source?
A. Floating strainer
B. Pipe strainer
C. Barrel strainer
D.Low-level strainer ( correct
answers ) answer: A NFPA 1002:
10.2.1, 10.2.1(A), 10.2.2, 10.2.2(A)
Page: 336
GRADED
A+

, 16.Which type of strainer requires 24 inches (0.5 m) of water in all
directions around the strainer?
A. Floating strainer
B. Pipe strainer
C. Barrel strainer
D.Low-level strainer ( correct
answers ) answer: C NFPA 1002:
10.2.1, 10.2.1(A), 10.2.2, 10.2.2(A)
Page: 336

17.What is the minimum water depth required to draft utilizing low-
level and floating strainers?
A. 12 inches (0.3 m)
B. 24 inches (0.5 m)
C. 36 inches (0.9 m)
D.48 inches (1.2 m) ( correct answers )
answer: B NFPA 1002: 10.2.1, 10.2.1(A),
10.2.2, 10.2.2(A)
Page: 336

19.What term refers to a small-diameter hose that remains in the
open position and continues flowing water during the entire drafting
operation?
A. Flow line
B. Attack line
C. Dump line
D.Hard suction line ( correct answers )
answer: C NFPA 1002: 10.2.1, 10.2.1(A),
10.2.2, 10.2.2(A)
Page: 340

20.If drafting with a two-staged pump, it is
recommended that the pump be in the
stage before beginning any
drafting operations.
A. pressure
B. series
C. drafting
D.volume ( correct
answers ) answer: D NFPA 1002: 10.2.1,
10.2.1(A), 10.2.2, 10.2.2(A)
Page: 340

20.When providing water to the operation for the purpose of master
streams from a static water source, the transfer valve in a two-stage pump
should be in the
position.
A. pressure
B. volume
GRADED
C. straight
A+
D. on ( correct answers ) answer: B
NFPA 1002: 10.2.1, 10.2.1(A), 10.2.2, 10.2.2(A)
Page: 341
$21.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
HopeJewels Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
70
Miembro desde
1 año
Número de seguidores
10
Documentos
8653
Última venta
1 día hace
macellen education agencies

On this page, you find all documents,testsbank ,solution manuals, package deals, On this page, you find all documents, package deals, and flashcards offered by seller Hopejewels

3.2

5 reseñas

5
2
4
0
3
1
2
1
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes