ID 344 CODES TEST (INTERNATIONAL ZONING CODE) EXAM QUESTIONS WITH CORRECT ANSWERS

Institución
INTERNATIONAL CODES ZONING
Grado
INTERNATIONAL CODES ZONING









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
INTERNATIONAL CODES ZONING
Grado
INTERNATIONAL CODES ZONING

Información del documento

Subido en
11 de mayo de 2025
Número de páginas
12
Escrito en
2024/2025
Tipo
Examen
Contiene
Desconocido

Temas

Vista previa del contenido

ID 344 CODES TEST (INTERNATIONAL
ZONING CODE) EXAM QUESTIONS
WITH CORRECT ANSWERS
Interior walls and partitions are required to be rated in Type I and Type II construction. -
ANSWER-False

Most combustible construction materials can be treated to gain some amount of fire
resistance. - ANSWER-True

Wood that is considered fire resistant because of its large diameter is called
_____________________________________________. - ANSWER-Heavy timber

Which construction type consists of exterior walls that are noncombustible but allows
interior elements to consist of combustible materials? - ANSWER-Type III

To determine if a certain occupancy classification can be located in a specific building,
which of the following do you need to know? - ANSWER-The construction type of the
building
The square footage (square meters) or area of the building
If the building is sprinklered

Which of the following limits a building's maximum size? - ANSWER-Construction
type(s)
Occupancy classification(s)
Proximity to other buildings

Which of the following would not affect the construction type during an interior
renovation? - ANSWER-Installing a ceramic tile floor over concrete

Which of the following would contribute to the sustainability of a building? - ANSWER-
Use of a steel structure
Management of the product waste during construction
Use of a local concrete supplier

Every element within the path of travel throughout a building is considered part of the
means of egress. - ANSWER-False

All interior egress doors must swing in the direction of travel to the exit. - ANSWER-
False

If the width of an alley or sidewalk is more than 10 feet (3048 mm) wide, it is no longer
considered a public way. - ANSWER-False

, The main difference between a corridor and an aisle is that a corridor is typically
surrounded by full‐height walls and an aisle is created by furniture or equipment. -
ANSWER-True

No doorway can be more than 48 inches (1220 mm) wide. - ANSWER-False

Name the three main interior‐related components of a means of egress. - ANSWER-Exit
Access
Exit
Exit Discharge

What component of a means of egress is sometimes required for persons with
disabilities? - ANSWER-Area of refuge

What are two types of door pulls that can be considered accessible? - ANSWER-The
most common answers include lever, push‐type, panic bar, and U‐shaped.

Which of the following are affected by means of egress requirements? - ANSWER-
Finish Selections
Fire Ratings of Walls

Which of the following means of egress must always be fully enclosed? - ANSWER-Exit
stair

An accessible ramp in a means of egress should have a slope no greater than what
ratio? - ANSWER-1:12

Which of the following statements about interior means of egress doors is not correct? -
ANSWER-They must have a minimum clear opening that is 36 inches (914 mm) wide.

Which of the following would most likely not be allowed as an intervening room as
required by the means of egress codes? - ANSWER-file/supply room in an advertising
firm

Which of the following items are typically required at an area of refuge? - ANSWER-A
two‐way communication device
A clear floor space

What is the typical minimum corridor width required by the building codes in most
occupancies? - ANSWER-44 inches (1118 mm)

In most cases, nothing is allowed to reduce the width of an exit. Which of the following
is a typical exception allowed by the codes? - ANSWER-Doors that do not project more
than 7 inches (178 mm) when fully open
Wall trim that is less than inch (13 mm) thick
$21.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
STUDYGUIDESET Bradford College
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
43
Miembro desde
2 año
Número de seguidores
17
Documentos
3141
Última venta
6 días hace
Anchor

on this page you will find al Exam materials, Exam ,package deal, Study Guide.

3.2

6 reseñas

5
1
4
1
3
3
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes