RADIOLOGIC TECHNOLOGY – DIGITAL RADIOGRAPHY (DR) PRACTICE TEST (140 QUESTIONS) – MOST TESTED QUESTIONS & COMPREHENSIVE EXAM REVIEW MATERIAL

Puntuación
-
Vendido
-
Páginas
34
Grado
A+
Subido en
08-05-2025
Escrito en
2024/2025

This document provides a complete set of 140 multiple-choice questions focused on digital radiography (DR) principles and systems. Topics include automatic exposure control (AEC), detector technology, sampling theory, image artifacts, DQE, and comparisons between CR and DR systems. It serves as a valuable resource for radiologic technology students preparing for certification exams or clinical competency.

Mostrar más Leer menos
Institución
RADIOLOGIC TECHNOLOGY – DIGITAL RADIOGRAPHY P
Grado
RADIOLOGIC TECHNOLOGY – DIGITAL RADIOGRAPHY P











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
RADIOLOGIC TECHNOLOGY – DIGITAL RADIOGRAPHY P
Grado
RADIOLOGIC TECHNOLOGY – DIGITAL RADIOGRAPHY P

Información del documento

Subido en
8 de mayo de 2025
Número de páginas
34
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

RADIOLOGIC TECHNOLOGY – DIGITAL RADIOGRAPHY (DR) PRACTICE
TEST (140 QUESTIONS) – MOST TESTED QUESTIONS &
COMPREHENSIVE EXAM REVIEW MATERIAL
To allow some flexibility in centering of the anatomy over different portions of the receptor
plate, most fixed DR units have detector cells in the plate for automatic exposure

control (AEC):

a. 1

b. 3

c. 5

d. 6 - ANSWER****c



Whenever there is an insufficient sampling rate for a high-frequency digital image, ______

artifacts may be created:

a. pixel drop-out

b. halo

c. reticulation

d. aliasing - ANSWER****d



When compared to CR, which of the following is not a disadvantage of DR:

a. Tendency to use the bucky grid for distal extremities

b. Less flexibility in positioning

c. Bulky and cumbersome receptor plates

d. Less consistency in image quality - ANSWER****d

,In the 1980s, the first clinically useful DR system consisted of a bar of large detectors connected
to photomultiplier tubes, which swept across the field area during exposure. This system was
called:

a. computed tomography

b. conventional tomography

c. linear positron emission tomography

d. scanned projection radiography

e. direct-scan radiography - ANSWER****d



For DR, the size of the individual detector elements (dexels) currently used is closest to:

a. 1 cm

b. 1 mm

c. 100 microns (1/10th mm)

d. 1 micron (1/1000th mm)

e. 1 nanometer - ANSWER****c



The Nyquist criterion states that to prevent aliasing, the sampling rate must be _____ the spatial
frequency of the image:

a. Equal to

b. At least twice

c. One-half

d. Four times - ANSWER****b



Which of the following would be caused by fluctuations in the electrical current passing through
the image acquisition system or digital processing system:

a. Electronic aliasing

b. Grid aliasing

,c. Electronic mottle

d. Material mottle - ANSWER****c



In digital imaging, missing lines or pixels can be caused by problems with:

a. computer memory

b. digitization

c. communication between the image acquisition system and the computer system

d. all of the above

e. b & c only - ANSWER****d



The development of which of the following enabled DR systems to use a flat-shaped receptor

plate:

a. thin-film transistors (TFTs)

b. electronic capacitors

c. photostimulable phosphor plates

d. the photomultiplier tube

e. flat light guides - ANSWER****a



Which of the following has the highest DQE, at 77%:

a. conventional screens and film

b. CR phosphor plates

c. direct-conversion DR plates

d. indirect-conversion DR plates - ANSWER****d



Which of the following terms, all contractions, most accurately describes the individual
hardware elements of a DR receptor plate that detect radiation in the remnant x-ray beam?

, a. the pixel

b. the dexel (or del)

c. the voxel

d. the rexel

e. the dynode - ANSWER****b



To a computer expert, a true pixel is a numerical value assigned to a(n):

a. small square area in the image

b. small circular area in the image

c. small square detector surface

d. small circular detector surface

e. point with no dimensions - ANSWER****e



In a DR image receptor, most of the square area of each dexel is dedicated to what portion of
the detector element:

a. the thin-film transistor

b. the semiconductor layer

c. the capacitor

d. the gate lines - ANSWER****b



For CR, the most common source of image artifacts is the:

a. patient

b. phosphor plate

c. reader (processor)

d. computer - ANSWER****b
$21.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
JAMES125 Chamberlain College Of Nursng
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
340
Miembro desde
2 año
Número de seguidores
42
Documentos
3230
Última venta
3 días hace
MY MAIN GOAL IS TO MAKE YOU PASS GOOD LUCK

MY MAIN GOAL IS TO MAKE YOU PASS GOOD LUCK. As a dedicated nursing student with a passion for helping peers succeed, I specialize in providing high-quality study resources on STUVIA including ATI modules and other essential certifications, earning excellent ratings and a stellar reputation for boosting students' grades. My commitment to excellence

5.0

3104 reseñas

5
3016
4
47
3
27
2
6
1
8

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes