100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

WMGT 101-22A EXAM 3 WITH 100- CORRECT ANSWERS

Puntuación
-
Vendido
-
Páginas
14
Grado
A+
Subido en
04-05-2025
Escrito en
2024/2025

WMGT 101-22A EXAM 3 WITH 100% CORRECT ANSWERS AFI 10-245, Antiterrorism - CORRECT ANSWERCE shall: have at least 1 engineer at each base must complete Security Eng AT Planning & Design Course, review, document, and track construction projects AT compliance, provide vulnerability assessment protection option program (VAPO) analysis for all critical facilities and off-base leases, and work with the Base Antiterrorism Officer

Mostrar más Leer menos
Institución
WMGT 101-22A
Grado
WMGT 101-22A









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
WMGT 101-22A
Grado
WMGT 101-22A

Información del documento

Subido en
4 de mayo de 2025
Número de páginas
14
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

WMGT 101-22A EXAM 3 WITH 100% CORRECT ANSWERS
AFI 10-245, Antiterrorism - CORRECT ANSWER✅✅✅CE shall: have at least 1 engineer at each base
must complete Security Eng AT Planning & Design Course, review, document, and track construction
projects AT compliance, provide vulnerability assessment protection option program (VAPO) analysis for
all critical facilities and off-base leases, and work with the Base Antiterrorism Officer



Antiterrorism Requirement Planning - CORRECT ANSWER✅✅✅1. UFC 4-020-01

2. Is only the minimum standard required?

3. Yes: construction standoff distance available?

No: UFC 4-020-02 and support manuals

4. If standoff distance is available, apply UFC 4-010-01 and support manuals



Design Basis Threat (DBT) - CORRECT ANSWER✅✅✅Baseline threat used in the design of protective
measures



Initial DBT - CORRECT ANSWER✅✅✅Based on planning team, local intel and Geographic Combatant
Command (COCOM) Theater-Wide threat assessments



Modify Initial DBT - CORRECT ANSWER✅✅✅Local threat assessments



Level of Protection - CORRECT ANSWER✅✅✅The degree to which an asset is protected, defines the
amount of damage a facility or asset can sustain during an attack



LOP: Very low - CORRECT ANSWER✅✅✅Progressive collapse is unlikely, but space in and around
damaged area will be unusable and onset of structural collapse occurs. Glazing is likely to be propelled
into the building and cause serious injuries. Doors may be propelled into rooms, presenting serious
hazards.



LOP: Low - CORRECT ANSWER✅✅✅Building will not be economically repairable and space in and
around damaged area will not be usable, but progressive collapse will not occur. Glazing will fracture
and may come out of the frame, but does not present a significant injury hazard. Doors may fail but
present minimal hazards.

, LOP: Medium - CORRECT ANSWER✅✅✅Minor damage, space in and around damaged area can be
used and will be fully functional after cleanup and repairs. Glazing will fracture but remain in the frame.
Doors may stay in frames but will not be reusable.



LOP: High - CORRECT ANSWER✅✅✅Minimal to no damage with no permanent definitions. Glazing
will not break. Doors will be reusable.



UFC 4-010-01 - CORRECT ANSWER✅✅✅DoD minimum antiterrorism standards for buildings. Intent
is to reduce mass casualties, minimize collateral damage to nearby facilities, and facilitate future
upgrades and increases FPCON.



UFC 4-020-01 - CORRECT ANSWER✅✅✅DoD Security Engineering Facility Planning Manual. Acts as a
starting point for Garrison Antiterrorism and a quantitative risk-based model. Uses scoring model to
evaluate asset value (0-1.0), threat likelihood (0-1.0), and use of minimum AT standards (<0.5). Includes
cost data and helps establish a DBT and required LOP.



AT/FP misconceptions - CORRECT ANSWER✅✅✅1. Bollards, fences, curbs, and barriers are and
adequate substitution for standoff

2. Existing roads must be moved away from existing buildings

3. All building require standoff



Mandatory design standards - CORRECT ANSWER✅✅✅Standard 1: Standoff distance

Standard 6: Progressive collapse

Standard 10: Glazing

Standard 16: Air Intakes



Minimum standoff distance - CORRECT ANSWER✅✅✅Smallest permissible standoff distance for
new and existing construction, regardless of analysis or hardening of the building. Not used for master
planning or programming.
$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
STANGRADES Stanford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
51
Miembro desde
1 año
Número de seguidores
1
Documentos
10172
Última venta
5 días hace
STAN-GRADES

EXCELLENCY IN ACADEMIC MATERIALS

3.4

11 reseñas

5
4
4
1
3
3
2
1
1
2

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes