1.What are the first four steps before starting any backflow test? - answer Notify Identify Inspect Observe 2.What does a leaking relief port on an RPBA indicate? (4) - answer Faulty check valve 1 or 2, Low up stream pressure Fluctuations in upstream pressure 3.What is the minimum height above the highest outlet or flood level rim for an AVB - answer 6" 4.Who is responsible for setting up a cross connection control program? - answer The water purveyor 5.Can elevated piping be considered a potential back siphonage condition? - answer Yes 6.Can undersized piping be considered a potential back siphonage condition? - answer Yes 7.Can potable water booster pumps be considered a potential back siphonage condition? - answer Yes 8.When testing a DCVA with sight tubes, about how long are the sight tubes? - answer 36" 9.Which test involves using a bypass hose to connect test port 1 to test port 3? - answer Confirmation test 10.What does the connection between test port 1 and 3 on a DCVA allow you to test? - answer Check valve 1 in the reverse direction 11.A backflow assembly which consists of only 2 internally loaded check valves.... - answer DuC dual check

Mostrar más Leer menos
Institución
Backflow Prevention Troubleshooting
Grado
Backflow prevention troubleshooting

Vista previa del contenido

Backflow Prevention latest 2025/2026 Practice exam with complete
100+ Questions and verified Solutions Graded at A+ Score| Sure
Guaranteed Pass!!


1.What are the first four steps before starting any backflow test? - answer Notify

Identify

Inspect

Observe



2.What does a leaking relief port on an RPBA indicate? (4) - answer Faulty check valve 1 or 2,

Low up stream pressure

Fluctuations in upstream pressure



3.What is the minimum height above the highest outlet or flood level rim for an AVB - answer 6"



4.Who is responsible for setting up a cross connection control program? - answer The water
purveyor



5.Can elevated piping be considered a potential back siphonage condition? - answer Yes



6.Can undersized piping be considered a potential back siphonage condition? - answer Yes



7.Can potable water booster pumps be considered a potential back siphonage condition? -
answer Yes



8.When testing a DCVA with sight tubes, about how long are the sight tubes? - answer 36"

,9.Which test involves using a bypass hose to connect test port 1 to test port 3? - answer
Confirmation test



10.What does the connection between test port 1 and 3 on a DCVA allow you to test? - answer
Check valve 1 in the reverse direction



11.A backflow assembly which consists of only 2 internally loaded check valves.... - answer DuC
dual check



12.Who can be liable for negligence, regulatory non-compliance or breach of contract? (5) -
answer The owner of the property

The plumbing contractor

The consulting engineer

The municipal inspector

The water purveyor



13.What is cross connection? - answer Any pipe, channel or link connecting a potable water
supply with a source of pollution, such that there may be a flow from the source of pollution to
the potable water.



14.What two ways can we affect water quality? - answer Pollution and contamination



15.Which is less severe, pollution or contamination? - answer Pollution is less but still non
potable



16.What does 1 cubic cm of water weigh? - answer .001 kg

,17.What does one psig = in kPa? - answer 6.9



18.What does 1 imp gallon weigh? - answer 10lbs



19.What does 1 US gallon weigh? - answer 8.33 lbs



20.How many gallons in a cubic foot? - answer 6.24imp gallons



21.How many inches of water column in 1 psi? - answer 27.7



22.Formula for TF? - answer Pressure x area



23.Calculate ft of head - answer Height x .433 psi/ft of head



24.Atmospheric pressure at sea level will support a column of water about how high? - answer
34ft



25.How often must an air gap be inspected if required? - answer Annually



26.A direction of flow in reverse to the normal direction is.... - answer Backflow



27.An ordinance would require a backflow preventer to be tested... - answer Annually



28.A connection where it is possible for non-potable fluid to enter a potable water system is
called? - answer Cross connection

, 29.When is a DIRECT connection between a potable water supply and a sewer connected waste
allowable? - answer Never



30.How many US GALLONS in a cubic foot? - answer 7.28

Containing a plumbing system from the public water supply requires backflow protection at the
_______?

A. Appliance or fixture

B. Building foundation

C. Irrigation system

D. Service Connection

E. Sprinkler riser - answer Service Connection



Backflow preventer manufacturers recommend that assemblies be field-tested annually and
when_____?

A. Installed

B. Moved

C. Repaired or Installed

D. Shut down

E. Water suppliers provide notice - answer Repaired or Installed



A differential pressure gauge reading of 0.2 psid is represented on water column sight tube by
_____?

A. 1/16 in. (0.16 cm)

B. 1/2 in. (1.3 cm)

C. 2 in. (5.1 cm)

D. 3.5 in. (8.9 cm)

E. 5.5 in. (14 cm) - answer 5.5 in. (14 cm)

Escuela, estudio y materia

Institución
Backflow prevention troubleshooting
Grado
Backflow prevention troubleshooting

Información del documento

Subido en
29 de abril de 2025
Número de páginas
32
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$15.09
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
Vintage
3.7
(3)

Conoce al vendedor

Seller avatar
Vintage Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
5
Miembro desde
1 año
Número de seguidores
0
Documentos
538
Última venta
4 meses hace
INTELLIGENCE HUB GET THE EPITOME OF EDUCATION.

Unlock your academic success with our comprehensive study documents (EXAMS, CASE STUDY, STUDY GUIDES, NOTES ETC.) Do you want better outcomes? Obtain well-prepared resources that are effective. Feeling overburdened by the pressure of exams? Our goal is to make things easier. With the aid of our study guides, you can maintain concentration, boost your self-esteem, and arrive to tests ready. Made from actual previous exams, they show you the kinds of questions you'll encounter and how to answer them effectively, allowing you to prepare more effectively and improve your marks. pick us because; we are Stuvia Gold-rated vendors by 950+ happy students; get Reliable resources for certification and healthcare achievement; Support that is responsive and kind when you need it.

Lee mas Leer menos
3.7

3 reseñas

5
2
4
0
3
0
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes