Residential - ANSWER -570 Data Centers - ANSWER -942 Class 1 - ANSWER -Single building with one equipment room Class 2 - ANSWER -Single building with multiple telecom spaces Class 3 - ANSWER -Multiple buildings on a single campus Class 4 - ANSWER -Multiple sites with multiple buildings Labels - ANSWER -Consist of face stock material Tags - ANSWER -Attached to the mounting surface Electronic identifieres - ANSWER -Prevent potential intruders from identifying the location of key components What is the minimum bend radius for a 50 mm (2in) conduit? - ANSWER -12 inches When installing optical fiber, consider placing three innerducts in a 103mm (4 trade size) conduit with the following sizes: - ANSWER -two 38 mm (1.5in), one 25mm (1in) Open top cable supports should be installed to provide a minimum of ________________ clearance above ceilings - ANSWER -3 inches PBB - ANSWER -dedicated extension of the building ac grounding (earthing) electrode system for the telecom bonding infrastructures TBC - ANSWER -bonds the electrical systems grounding (earthing) electrode system to the PBB TBB - ANSWER -interconnects the PBB to the SBB BBC - ANSWER -used to equalize potentials between SBBs on the same floor of a structure. Which is better for an "L" rating? High or Low Numbers - ANSWER -Low F rating- how many hours - ANSWER -1-4 Hrs T rating- how many hours - ANSWER -0-3 Hrs Electric motors and transformers - ANSWER -48" Fluorescent Lamps - ANSWER -6" Arc Welders - ANSWER -31.5" Frequency Induction Heating - ANSWER -39" Which OLTS testing method stimulates the loss of two mated pairs and an

Mostrar más Leer menos
Institución
BICSI TECHNICIAN 2
Grado
BICSI TECHNICIAN 2









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
BICSI TECHNICIAN 2
Grado
BICSI TECHNICIAN 2

Información del documento

Subido en
29 de abril de 2025
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

BICSI TECHNICIAN EXAM LATEST QUESTIONS WITH
100% CORRECT ANSWERS


Residential - ANSWER -570

Data Centers - ANSWER -942

Class 1 - ANSWER -Single building with one equipment room

Class 2 - ANSWER -Single building with multiple telecom spaces

Class 3 - ANSWER -Multiple buildings on a single campus

Class 4 - ANSWER -Multiple sites with multiple buildings

Labels - ANSWER -Consist of face stock material

Tags - ANSWER -Attached to the mounting surface

Electronic identifieres - ANSWER -Prevent potential intruders from identifying
the location of key components

What is the minimum bend radius for a 50 mm (2in) conduit? - ANSWER -12
inches

When installing optical fiber, consider placing three innerducts in a 103mm (4 trade
size) conduit with the following sizes: - ANSWER -two 38 mm (1.5in), one 25mm
(1in)

Open top cable supports should be installed to provide a minimum of
________________ clearance above ceilings - ANSWER -3 inches

PBB - ANSWER -dedicated extension of the building ac grounding (earthing)

, electrode system for the telecom bonding infrastructures
TBC - ANSWER -bonds the electrical systems grounding (earthing) electrode
system to the PBB

TBB - ANSWER -interconnects the PBB to the SBB

BBC - ANSWER -used to equalize potentials between SBBs on the same floor of
a structure.

Which is better for an "L" rating? High or Low Numbers - ANSWER -Low

F rating- how many hours - ANSWER -1-4 Hrs

T rating- how many hours - ANSWER -0-3 Hrs

Electric motors and transformers - ANSWER -48"

Fluorescent Lamps - ANSWER -6"

Arc Welders - ANSWER -31.5"

Frequency Induction Heating - ANSWER -39"

Which OLTS testing method stimulates the loss of two mated pairs and an
installed optical fiber link? - ANSWER -One jumper method

What can cause a gain splice on an OTDR trace? - ANSWER -Mismatch in the
fibers
L Rating - ANSWER -A firestops ability to provide a smoke stop. (air leakage
rate)

To avoid damaging cable jacket, how often must you securely fasten electrical
nonmetallic tubing (ENT) - ANSWER -3 Feet so it does not damage the cable What
$10.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
rachaelmumbi

Conoce al vendedor

Seller avatar
rachaelmumbi Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
0
Miembro desde
9 meses
Número de seguidores
0
Documentos
53
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes