voxel contains 25% air, 50% water and 25% bone. The CT number for this voxel would be expected to be _____ HU? - CorreCt Answers -0 How many pixels are contained in a 1,024 matrix image? - CorreCt Answers -D. 1,048,576 MATH 1024 X1024 It is located in a matrix and is a two dimensional representation of a voxel - CorreCt Answers -pixel When CT numbers are calculated for voxels (volume elements) of tissue what is assigned the calculated number and a subsequent shade of gray - CorreCt Answers -pixel What is defined as a picture element or the smallest component of the digital image - CorreCt Answers -pixel A CT scan produces a 512x512 matrix transverse image of a 30 cm diameter FOV. Each pixel is approximately _____ mm on a side. - CorreCt Answers -0.6 equation: 30cm/512= .058cm convert to mm and its .58 which is approximately 0.6The ability of a system to define small objects distinctly is referred to as which of the following? - CorreCt Answers -spatial resolution Which of the following terms is/are commonly used to describe a CT scanner's ability to differentiate objects with similar linear attenuation coeffiecents - CorreCt Answers -*spatial resolution *sensitivity Which of the following factors have an affect on contrast resolution - CorreCt Answers -*patient size *slice thickness *pixel size *mAs/dose As mAs/dose increases contrast resolution decreases - CorreCt Answers - FALSE

Vista previa del contenido

MOSBY CT REGISTRY REVIEW EXAM WITH
HIGHEST PROBILITY 100%PASS.

A voxel contains 25% air, 50% water and 25% bone. The CT number for this
voxel would be expected to be _____ HU? - CorreCt Answers -0


How many pixels are contained in a 1,024 matrix image? - CorreCt
Answers -D. 1,048,576



MATH 1024 X1024


It is located in a matrix and is a two dimensional representation of a voxel -
CorreCt Answers -pixel



When CT numbers are calculated for voxels (volume elements) of tissue
what is assigned the calculated number and a subsequent shade of gray -
CorreCt Answers -pixel



What is defined as a picture element or the smallest component of the
digital image - CorreCt Answers -pixel


A CT scan produces a 512x512 matrix transverse image of a 30 cm diameter
FOV. Each pixel is approximately _____ mm on a side. - CorreCt Answers
-0.6 equation: 30cm/512= .058cm convert to mm and its .58 which is
approximately 0.6

,The ability of a system to define small objects distinctly is referred to as
which of the following? - CorreCt Answers -spatial resolution


Which of the following terms is/are commonly used to describe a CT
scanner's ability to differentiate objects with similar linear attenuation
coeffiecents - CorreCt Answers -*spatial resolution
*sensitivity


Which of the following factors have an affect on contrast resolution -
CorreCt Answers -*patient size

*slice thickness
*pixel size
*mAs/dose


As mAs/dose increases contrast resolution decreases - CorreCt Answers -
FALSE


As mAs/dose increases contrast resolution INCREASES - CorreCt Answers
-TRUE



The ability of a CT scanner to accurately image objects with similar
densities is termed - CorreCt Answers -*contrast resolution
*sensitivity


Which of the following has a direct relationship on increasing contrast
resolution - CorreCt Answers -*mAs/dose increase
*Slice thickness

,For a particular CT scanner's beam quality, the linear attenuation
coefficient for water is 0.20 cm-1 and for a certain tumor is 0.21 cm-1. What
is the CT number of the tumor? - CorreCt Answers -50. Equation (.21-
.20/.21) × 1000= 50


A CT scanner with poor contrast resolution or low sensitivity has difficulty
separating - CorreCt Answers -tissues whose linear attenuation coefficients
are nearly equal


What is the basic physical quantity being measured by a CT system -
CorreCt Answers -Linear attenuation coefficient



Assume the linear attenuation coefficient is 0.20 cm-1 for water and 0.40
cm-1 for tissue within a given voxel. What is the CT number in Hounsfield
units for the pixel representing this voxel? - CorreCt Answers -
+1,000....Equation { (.4-.2) /.2} x 1000


What fraction of monoenergetic x-rays will be absorbed by a 20-cm thick
material having a linear attenuation coefficient of 0.05 cm-1? - CorreCt
Answers -0.63



The contrast resolution of CT is approximately ? % - CorreCt Answers -0.3
to 0.6


This term describes the ability CT scanner to differentiate objects with
MINIMAL differences in attenuation coefficients - CorreCt Answers -
contrast resolution

, What is the term for resolution of a CT scanner referred to as the system's
ability to differentiate objects with SIMILAR densities. - CorreCt Answers -
contrast resolution


In order to pass ACR CT accreditation, the CT scanner's adult head protocol
must be within - CorreCt Answers -1.0


The QC test for the average CT number for water should be done - CorreCt
Answers -Daily



The following are all basic tenets of a QC program for computed
tomography scanner - CorreCt Answers -*QC test must be conducted
regularly
*Accurate record keeping
*all test results must be interpreted promptly


Using the ACR CT accreditation phantom, module 3 is used to measure
which of the following - CorreCt Answers -CT number uniformity


The following QC test should be done on a monthly basis - CorreCt
Answers -high contrast resolution



The CT number at the center of a uniformly filled water phantom should
ideally be - CorreCt Answers -0


The ACR CT accreditation phantom is designed to perform QC
measurements of - CorreCt Answers -*positioning accuracy and light
accuracy alignment only

Información del documento

Subido en
25 de abril de 2025
Número de páginas
87
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$25.86

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
munenebeth20
1.0
(1)
Vendido
1
Seguidores
0
Artículos
333
Última venta
6 meses hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes