S12 SPRINKLER TEST, S13 STANDPIPE TEST,
SPRINKLERS SEGMENT 5, S-12 CITYWIDE
SPRINKLER SYSTEMS QUESTIONS AND
ANSWERS
fire department connection - CORRECT ANSWER- normally on exterior of building...
FDNY can pump supplemental water into the sprinkler system, standpipe, or other
system furnishing water for fire extinguishment to supplement existing water supplies.


system control valve - CORRECT ANSWER- valve controlling flow to water-based fire
protection systems.


fire command center - CORRECT ANSWER- Designated room or area in a structure
where the status of the fire detection, alarm, and protection systems is displayed and
the systems can be manually controlled.


Fire pump, automatic standpipe. - CORRECT ANSWER- A fire pump located at or
below street level that supplies the lower 300 feet (91.4 m) of a standpipe system or a
combined standpipe and sprinkler system.


tags - CORRECT ANSWER- on closed section valves serving affected areas: area
affected, brief description, occupancy classification, c of f number, estimated time until
operational


Green tag - CORRECT ANSWER- no impairment found in entire system- main control
valve


red tag - CORRECT ANSWER- place on main control valve if FULLY out of service...
put sprinkler company name, date of removal from service and anticipated time to
operational

,blue disk - CORRECT ANSWER- partially out of service- on all fire department
connections


water storage tank - CORRECT ANSWER- Collects cooled water


OS & Y valve - CORRECT ANSWER- indicating type of control valve used for fire
sprinkler system


deluge valve - CORRECT ANSWER- water supply control valve intended to be
operated by actuation of an automatic detection system that is installed in the same
area as the discharge devices. INTENDED USE IS MANUAL AND AUTO


deluge sprinkler system - CORRECT ANSWER- employing open sprinklers that are
attached to a piping system that is connected to a water supply through a valve that is
opened by the operation of a detection system installed in the same areas as the
sprinklers. WHEN IT OPENS, water flows into the piping system and discharges from all
sprinklers attached.


Early suppresion fast response sprinklers - CORRECT ANSWER- fast response
sprinkler that is listed for its capability to provide fire suppression of specific high
challenge fire hazards


extra large orifice sprinklers - CORRECT ANSWER- = or > 1 inch less pressure to
achieve a given discharge density


extended coverage sprinkler - CORRECT ANSWER- 400 max square feet discharge 20
foot by 20 foot spacing between sprinklers


fire pump - CORRECT ANSWER- a provider of liquid flow and pressure dedicated to
fire protection. A fire pump is a part of a fire sprinklers system water supply and can be

,powered by electric, diesel or steam. connected to public water source or tank. provides
higher pressure to sprinkler system


Glass bulb sprinkler - CORRECT ANSWER- operated by heat breaking a glass bulb
filled with a non freezing liquid with diameters that vary form 3 mm for quick response to
5 mm for standard response


hose valve - CORRECT ANSWER- valve to additional hose connection


hydraulic placard - CORRECT ANSWER- sign attached to a hydraulically calculated
sprinkler system indicating the design density, required gallons per minute and pressure
for the system to operate properly


hydraulically calculated systems - CORRECT ANSWER- method of sizing auto sprinkler
piping using a prescribed amount of water to be distributed over a specific area.


impairment coordinator - CORRECT ANSWER- in charge of safety during out of service
systems


intermediate level sprinkler - CORRECT ANSWER- sprinkler equipped with integral
shields to protect the operating elemtn form discharge from sprinklers installed at higher
elevations


large orifice sprinkler - CORRECT ANSWER- sprinkler head with orifice size equal or
greater than 3/4 and less than 1 inch


listed device - CORRECT ANSWER- A fire protection component that has been tested
to perform under parameters specified for its use by a nationally recognized testing
agency. Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most
common.

, Master Pressure Reducing Valve - CORRECT ANSWER- A pressure reducing valve
installed to regulate pressures in an entire fire protection system and/or standpipe
system zone.


Main Drain - CORRECT ANSWER- The primary drain connection located on the system
riser and also utilized as a flow test connection.


Microbiologically Influenced Corrosion (MIC) - CORRECT ANSWER- Corrosion caused
by the presence of microbes in the water supply that over time attack the interior of
metallic piping and cause leaks, pitting, and blockages.


Old-Style/Conventional Sprinkler - CORRECT ANSWER- A sprinkler that directs 40% to
60% of the water initially in a downward direction and is designed to be installed with
the deflector in either the upright or pendent position.


Pendent Sprinkler - CORRECT ANSWER- A sprinkler designed to be installed in such a
way that the water stream is directed downward against the deflector.


Pintle Screws - CORRECT ANSWER- A visual indicating device required for sprinklers
manufactured prior to 1999 identifying small orifice sprinklers and large orifice sprinklers
where orifice size is different than the nominal thread size of the sprinkler head.


Pipe Schedule Systems - CORRECT ANSWER- A method of sizing piping based upon
the number of sprinkler heads and the occupancy of the protected area.


Preaction Sprinkler System - CORRECT ANSWER- A sprinkler system employing
automatic sprinklers that are attached to a piping system that contains air that may or
may not be under pressure, with a supplemental detection system installed in the same
areas as the sprinklers.

Escuela, estudio y materia

Institución
S12 sprinkler test, S13 standpipe
Grado
S12 sprinkler test, S13 standpipe

Información del documento

Subido en
24 de abril de 2025
Número de páginas
47
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$19.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
NurseMitch NURSING, ECONOMICS, MATHEMATICS, BIOLOGY, AND HISTORY MATERIALS BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS, AND STUDY GUIDE MATERIALS WITH GUARANTEED A+ I am a dedicated medical practitioner with diverse knowledge in matters
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
53
Miembro desde
1 año
Número de seguidores
3
Documentos
1123
Última venta
1 semana hace
nurse mitch

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. I WISH YOU SUCCESS IN YOUR EDUCATION JOURNEY Buy without Doubt.

Lee mas Leer menos
4.8

101 reseñas

5
89
4
9
3
1
2
0
1
2

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes