50 ft. - ANS✔✔--OSHA specified maximum travel distance to an extinguisher for Class B

6 yrs - ANS✔✔--dry chem extinguishers requiring 12 yr hydrostatic test must be emptied for
maintenance procedures every

A rated UL extinguishers = how many gallons of water? - ANS✔✔--1.25

C - ANS✔✔--Class ____ fire extinguishers use electrically nonconductive extinguishing agents

Every 5 years - ANS✔✔--Cartridge operated water based portable extinguishers need hydrostatic
testing

stored pressure type extinguishers need need INTERNAL examination : - ANS✔✔--never

5 ft above the ground - ANS✔✔--extinguishers weighing 40 lbs or less must be installed so top of
canister is no more than _____

K - ANS✔✔--class ___ extinguishers are for fires involving cooking media

75 ft - ANS✔✔--OSHA specified max travel distance for Class A is ______

C - ANS✔✔--proper UL rating to use on electrically energized equipped

Class K - ANS✔✔--work on the principle of saponification

Obstacle Type Fires - ANS✔✔--involve flammable liquid on a horizontal surface w/ the presence of
a solid object creating a barrier

4 inches - ANS✔✔--extinguishers must be installed at least _____ from the ground

Obstacle Type Fires - ANS✔✔--may take place in flammable liquid storage caninets, dip tank
process areas, etc.

, Must Be Weighed - ANS✔✔--To make sure the pressure gauges of CO2 extinguisher are showing
adequate pressure, what must you do?

5 yrs - ANS✔✔--Wetting agent portable extinguishers must be hydrostatic tested every _____

After recharge - ANS✔✔--leak tests on stored pressure extinguishers must be performed

cannot - ANS✔✔--how do u convert fire extinguishers from 1 type to another?

any remaining dry chemical in a discharged extinguisher - ANS✔✔--may be reused only if checked
for proper type, contamination, and condition. closed recovery system needs to be used!

New extinguishers needing charge in the field - ANS✔✔--do not need to have any verification of
service collar installed

you cannot - ANS✔✔--how do u have an extinguisher converted to use a different type of
extinguishing agent

annually - ANS✔✔--the gauge used to set the regulated source of pressure needs to be calibrated

annually - ANS✔✔--pump tank calcium chloride based antifreeze typesof extinguishers need to be
recharged

75 ft. - ANS✔✔--OSHA specified max distance to extinguisher for Class D

weighing - ANS✔✔--when you recharge, the amount of recharge agent to use should be verified by

Aqueous Film Forming Foam (AFFF) - ANS✔✔--these types of extinguishers must have hydrostatic
testing every 5 yrs

annually - ANS✔✔--The wetting agent in stored pressure wetting agent extinguishers must be
replaced

3 yrs - ANS✔✔--The premixed agent in liquid charge-type AFFF and FFFP extinguishers must be
replaced every

cylinder-operated extinguishers - ANS✔✔--do not need to have any verification of service collar
installed

False - ANS✔✔--you are free to mixmultipurpose dry chemicals w/ alkaline based dry chemicals

must be avoided - ANS✔✔--subsurface injection of wet chemical extinguishing agents into hot
cooking media

False - ANS✔✔--You should NEVER place extinguishers in cabinets or wall recesses.

Información del documento

Subido en
18 de abril de 2025
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$21.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BEST100
4.4
(18)
Vendido
55
Seguidores
34
Artículos
1138
Última venta
1 semana hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes