100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NATE AIR CONDITIONING AND HEAT PUMPS FINAL EXAM PREP 2025/2026 ACCURATE QUESTIONS WITH CORRECT DETAILED ANSWERS ||100% GUARANTEED PASS <RECENT VERSION>

Puntuación
-
Vendido
-
Páginas
38
Grado
A+
Subido en
12-04-2025
Escrito en
2024/2025

NATE AIR CONDITIONING AND HEAT PUMPS FINAL EXAM PREP 2025/2026 ACCURATE QUESTIONS WITH CORRECT DETAILED ANSWERS ||100% GUARANTEED PASS &lt;RECENT VERSION&gt;

Institución
NATE AIR CONDITIONING AND HEAT PUMPS
Grado
NATE AIR CONDITIONING AND HEAT PUMPS











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NATE AIR CONDITIONING AND HEAT PUMPS
Grado
NATE AIR CONDITIONING AND HEAT PUMPS

Información del documento

Subido en
12 de abril de 2025
Número de páginas
38
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

1



NATE AIR CONDITIONING AND HEAT PUMPS FINAL
EXAM PREP 2025/2026 ACCURATE QUESTIONS WITH
CORRECT DETAILED ANSWERS ||100% GUARANTEED
PASS <RECENT VERSION>
Which of the following factors affects a customer's level of comfort?



a. Air movement

b. Humidity

c. Temperature

d. All of the above - (answers)d (All of the above: air movement, humidity,
temperature)



A cooling load calculation estimates the sensible heat gain of a structure. The
maximum sensible capacity of a cooling-only system should be within ____% of
this calculated value.



a. ±10%

b. +10%

c. +15%

d. +30% - (answers)c (+15%)



The maximum sensible cooling capacity of a heat pump should be within ____%
of the calculated sensible heat gain of a structure with a large heating load.

, 2


a. ±10%

b. +15%

c. -25%

d. +25% - (answers)d (+25%)



The combined output of a heat pump and its auxiliary heat should not exceed the
calculated heat loss of a home by more than ____%.



a. 10%

b. 15%

c. 20%

d. 25% - (answers)b (15%)



What amount of auxiliary electric heat is needed when the output of a heat pump
on a design day equals 18,800 Btuh and the heat loss of a home is 29,700 Btuh?



a. 2.1 kWh

b. 3.2 kWh

c. 5.0 kWh

d. 10.9 kWh



Note: 3,413 Btu/kW - (answers)b (3.2 kWh)

, 3




The three processes that transfer heat energy are conduction, convection, and
____.



a. concentration

b. radiation

c. refraction

d. static pressure - (answers)b (radiation)



Heat transfer that occurs when substances of different temperatures are in
contact with each other is called ____.



a. concentration

b. conduction

c. convection

d. radiation - (answers)b (conduction)



What effect does raising the pressure in a sealed system have on refrigerant?



a. It becomes more difficult to subcool the liquid refrigerant

b. It becomes more difficult to superheat the refrigerant vapor

c. The refrigerant's boiling point decreases

, 4


d. The refrigerant's boiling point increases - (answers)d (The refrigerant's boiling
point increases)



What is the primary danger to people near an accidental refrigerant release or
spill?



a. Blurred vision caused by the refrigerant vapor coming in contact with the eyes

b. Changes in weather patterns caused by global warming

c. Damage to the food chain caused by decreased ozone levels in the stratosphere

d. Suffocation caused by the heavier refrigerant displacing oxygen in the air -
(answers)d (Suffocation caused by the heavier refrigerant displacing oxygen in the
air)



The maximum temperature at which refrigerant may be stored is ____°F when
the container is no more than ____% full of liquid by volume.



a. 120°F, 60%

b. 125°F, 60%

c. 125°F, 80%

d. 135°F, 80% - (answers)c (125°F, 80%)



Boiling of the refrigerant occurs in which system component?
$20.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
DocBeast Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
8356
Miembro desde
11 meses
Número de seguidores
3
Documentos
2778
Última venta
4 días hace

5.0

617 reseñas

5
600
4
15
3
1
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes