100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

C R C S T FINAL EXAM 2024/2025 WITH QUESTIONS AND VERIFIED CORRECT ANSWERS/ ALREADY GRADED A++

Puntuación
-
Vendido
-
Páginas
96
Grado
A+
Subido en
11-04-2025
Escrito en
2024/2025

C R C S T FINAL EXAM 2024/2025 WITH QUESTIONS AND VERIFIED CORRECT ANSWERS/ ALREADY GRADED A++ C R C S T FINAL EXAM 2024/2025 WITH QUESTIONS AND VERIFIED CORRECT ANSWERS/ ALREADY GRADED A++

Institución
CRCST
Grado
CRCST











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
CRCST
Grado
CRCST

Información del documento

Subido en
11 de abril de 2025
Número de páginas
96
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

C R C S T FINAL EXAM 2024/2025 WITH QUESTIONS AND
VERIFIED CORRECT ANSWERS/ ALREADY GRADED A++


Tube black structures that connect the kidneys to the urinary bladder -
ANSWER Ureters

To remove ions which have an electrical charge - ANSWER Deionize

Water that has been treated and is acceptable for drinking - ANSWER
Portable Water

The two most common techniques of flat wrap packaging are - ANSWER
Square-fold and envelope-fold

Tracking patient care equipment can prevent equipment shortages -
ANSWER True

The inventory system that stock supplies by established stock level is
called - ANSWER Par-Level

In central service, the concept of "one way flow of materials" refers to the
movement of products - ANSWER From soiled areas to clean processing
areas within central service

When loading a steam sterilizer items with soiled bottoms, should be -
ANSWER Placed on edge

Used an ear surgery and for driving very small wires through the bone -
ANSWER Micro drill

"Pneumonectomy" is - ANSWER Surgical removal of the lung

Last sterilization of implants is NOT recommended by - ANSWER AMMI &
AORN

The pathway that food takes through the digestive system - ANSWER
alimentary canal

,This part of the nervous system, many automatic body functions like the
heartbeat and breathing - ANSWER Brain Stem

"DIS" is - ANSWER Apart, away

The hip joint is an example of - ANSWER ball and socket joint

The term "superheated steam" means - ANSWER Dry steam

The two most common temperatures use in steam sterilization are -
ANSWER 250 Celsius
270-275 Fahrenheit

OSHA blood-borne pathogen standard requirements: - ANSWER - provide
hepatitis B vaccine to employees at no cost
- Observe standard precaution
- use engineering controls to prevent biohazard exposure

The term "excise" means - ANSWER To cut out

In the ABC inventory control system "A" items represent - ANSWER The
smallest number of items and the largest dollar

Michael, grind, or Supercuts scissors are usually identified with a black
handle - ANSWER True

This tissue connects, one bone to another - ANSWER ligament

Which of the following would be the best choice for HIGH-LEVEL
disinfection of instruments? - ANSWER OPA (Ortho-Phthalaldehyde)

These muscles control, involuntary movements, like breathing and
digestion - ANSWER smooth muscle

Endotracheal tubes and anesthesia breathing circuits are examples of -
ANSWER Semi-critical device

The largest part of the human brain is the - ANSWER Cerebrum

Inanimate objects that can transmit bacteria are called - ANSWER fomites

,Kerrison/laminectomy rongeurs should be tested using - ANSWER an
index card

This surgical procedure is the removal of a testicle - ANSWER orchiectomy

Disposable sharp items (blades, needles, etc.) should be removed at point
of use in place in a _______ container, labeled BIOHAZARD - ANSWER
Hard side

The use of HEAT to kill microorganisms EXCEPT spores - ANSWER
thermal disinfection

CANNOT be immersed - ANSWER Powered surgical instruments

Term relating to infectious agents, presenting a risk to human health -
ANSWER Biohazard

Process by which all forms of microorganisms are completely destroyed -
ANSWER sterilization

A common disinfectant that must remain in wet contact with the item being
disinfected for at least five minutes - ANSWER Alcohol

Used as both antiseptic and disinfectant. Should NOT be used on surgical
instruments due to its staining properties. - ANSWER Iodophors

Process by which a solution is combined with an activating chemical before
use. Glutaradehydes must be activated before initial use - ANSWER
Activation

A desired solution for cleaning instruments - ANSWER detergent

______ should be spot cleaned IMMEDIATELY - ANSWER Spills

Tapwater should I ideally have a chlorine concentration of _____ ppm or
less - ANSWER 250

The number of times per year, that inventory is purchased, consumed, and
replace is called the - ANSWER Inventory turnover rate

, Which of the following are classified as high-level disinfectants - ANSWER
Glutaraldehyde and OPA

Used to visualize the entire large intestine - ANSWER colonoscope

The use of positive and negative air pressure in the central service
department is designed to take the place of heating and air conditioning -
ANSWER False

The Bowie dick test should be run in - ANSWER dynamic air removal
steam sterilizers

Bowie dick test - ANSWER Is specifically used to evaluate the
effectiveness of air removal in steam sterilizers

When attached to the bone this tissue makes body movement possible -
ANSWER muscular tissue

This surgery uses implants like screws and plates to realign a fractured
bone - ANSWER Open reduction internal fixation(ORIF)

Which of the following is an example of regulated medical waste -
ANSWER blood soaked sponges

Regulated medical waste - ANSWER Is considered anything hazardous
and can expose risk to patients

What would be the recommended exposure time for a dry heat sterilization
load that was run at an exposure temperature of 320°F (160°F) - ANSWER
2 hours

Which of the following sterilization quality assurance measurements is
designed to provide a written record of sterilizer cycle activity - ANSWER
mechanical recording charts/printouts

The probability of a viable microorganism being present on an item after
sterilization is the ___________________________. - ANSWER sterility
assurance level (SAL)
$25.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
phoebemigwi Johns Hopkins University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
22
Miembro desde
1 año
Número de seguidores
1
Documentos
311
Última venta
6 meses hace

3.0

2 reseñas

5
1
4
0
3
0
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes