Establishing notification zones within premises shall ____________________. - be consistent with the building evacuation plan. In a common talk system if the control equipment does not indicate the location of the telephone station or telephone jack shall be clearly and permanently labeled to ________________________. - Identify his or her location to the control center by voice. The maximum number of water-flow switches that can be connected to a initiating device circuit is ____. - 5 The maximum allowable response delay on an alarm signal from an initiating device shall receipt by the control unit shall be _________. - 10 Seconds A lobby smoke detector shall be located in the ceiling within ___________ of the centerline of each elevator door within the elevator bank under control of the detector. - 21 feet

Vista previa del contenido

FSDNY S98 MAIN EXAMINATION TEST 2025/2026
QUESTIONS WITH ANSWERS GRADED A+
✔✔Establishing notification zones within premises shall ____________________. -
✔✔be consistent with the building evacuation plan.

✔✔In a common talk system if the control equipment does not indicate the location of
the telephone station or telephone jack shall be clearly and permanently labeled to
________________________. - ✔✔Identify his or her location to the control center by
voice.

✔✔The maximum number of water-flow switches that can be connected to a initiating
device circuit is ____. - ✔✔5

✔✔The maximum allowable response delay on an alarm signal from an initiating device
shall receipt by the control unit shall be _________. - ✔✔10 Seconds

✔✔A lobby smoke detector shall be located in the ceiling within ___________ of the
centerline of each elevator door within the elevator bank under control of the detector. -
✔✔21 feet

✔✔Alarm verification time cannot delay the alarm longer than ____________ if a smoke
detector is programmed for alarm verification. - ✔✔60 seconds

✔✔Visual notification appliances on a fire alarm system shall not be located more than
__________ from the end of the corridor. - ✔✔15 feet

✔✔The minimum audible level that is required for a sleeping area is _____ and must be
measured at the ______. - ✔✔75db; pillow

✔✔The total sound pressure level produced by combining the ambient sound pressure
level with all audible notification appliances operating in the occupied area shall not
exceed ______. - ✔✔110db

✔✔The minimum required light output for a single wall mounted visible notification
appliance on a 50ft by 50ft room is ________. - ✔✔94CD

✔✔In 40 feet by 40 feet room with 10 feet high ceiling ________ is the number of 15cd
strobe lights installed. - ✔✔4

✔✔An office space has an ambient sound level of 60dba, the minimum sound level
required to ensure that alarm signals are clearly heard should be ______. - ✔✔75dba

, ✔✔The average ambient sound level for business occupancies is _______. - ✔✔60dba

✔✔When connecting visual notification appliances to the fire alarm system, the flashes
shall not exceed ______________. - ✔✔two flashes per second

✔✔When connecting visual notification appliances on a fire alarm system, the flash rate
shall not exceed ____________. - ✔✔two flashes per second

✔✔______ is the number of speakers required for each notification zone. - ✔✔two

✔✔A speaker is tapped at 1/4 watt and produces a sound level of 75db, if the speaker
is tapped the 1 watt will produce _____. - ✔✔81db

✔✔A DACT shall be configured to seize the phone lines by __________________. -
✔✔disconnecting the outgoing and incoming calls by off hook

✔✔If either transmission channel for a DACT fails a trouble signal shall be sent within
________________. - ✔✔240 seconds / 4 minutes

✔✔If either transmission channel for a DACT fails, a trouble signals shall be sent within
____________. - ✔✔240 seconds / 4 Minutes

✔✔A failure of a dact to transmit an alarm shall not prevent subsequent attempts,
__________________________. - ✔✔up to a minimum of 5 and a maximum of 10 have
been attempted

✔✔In the event of loss of primary lighting for a proprietary supervising station the
emergency light shall operate for not less than ________. - ✔✔26 Hours

✔✔Upon recite of trouble signal pertaining solely to matters of equipment maintenance
of the fire alarm system, the proprietary supervising station operator shall initiate action
to perform the following:
______________________________________________________________. -
✔✔Dispatch personnel to arrive within four (4) hours to initiate maintenance if
necessary. Notify the AHJ when interruption of service exists for four (8) hours or more.

✔✔The central station shall dispatch personnel to arrive within ______ if protected
premises equipment needs to be manually reset after testing. - ✔✔2 hours

✔✔Low power radio transmitters shall automatically repeat alarm transmission at
intervals not exceeding __________ until the initiating device is returned to its non-
alarm condition. - ✔✔60 seconds

Información del documento

Subido en
4 de abril de 2025
Número de páginas
10
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$11.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EXAMCAFE
3.3
(18)
Vendido
152
Seguidores
7
Artículos
26057
Última venta
2 días hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes