Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

WRITTEN EXAM REVIEW PRACTICE TEST 1 AND 2 WITH CORRECT QUESTIONS AND ANSWERS.

Puntuación
-
Vendido
-
Páginas
9
Grado
A
Subido en
03-04-2025
Escrito en
2024/2025

assuming all other conditions remain constant, a decrease in evaporator load causes - CORRECT ANSWERS.️️low suction pressure in a flooded evaporator using an accumulator and float valve, flash gas - CORRECT ANSWERS.️️passes directly into the suction line the oil trap on a refrigeration system is on the - CORRECT ANSWERS.️️discharge line, as close to the compressor as allowed what controls the operation of a high-side float? - CORRECT ANSWERS.️️the condenser, and receiver when suction pressure decreases,compressor capacity - CORRECT ANSWERS.️️decreases cooling-tower water should be maintained at a p h near - CORRECT ANSWERS.️️7.8 the sub cooling effect of the liquid refrigerant just before the expansion valve causes increased - CORRECT ANSWERS.️️refrigeration effect sub cooling the liquid refrigerant just before the expansion valve, results in an increase in - CORRECT ANSWERS.️️refrigeration effect what percent of oil travels with the refrigerant? - CORRECT ANSWERS.️️10 percent any water present in the refrigerant side of a freon refrigeration system causes a - CORRECT ANSWERS.️️frozen expansion valve when heated, R-12 changes to - CORRECT ANSWERS.️️phosgene gas in an absorption system, the medium normally used to vaporize refrigerant and increase its temperature is - CORRECT ANSWERS.️️steam

Mostrar más Leer menos
Institución
Ammonia Refigdweration
Grado
Ammonia refigdweration

Vista previa del contenido

WRITTEN EXAM REVIEW PRACTICE
TEST 1 AND 2 WITH CORRECT
QUESTIONS AND ANSWERS.

assuming all other conditions remain constant, a decrease in evaporator load causes - CORRECT
ANSWERS.✔️✔️low suction pressure



in a flooded evaporator using an accumulator and float valve, flash gas - CORRECT
ANSWERS.✔️✔️passes directly into the suction line



the oil trap on a refrigeration system is on the - CORRECT ANSWERS.✔️✔️discharge line, as close to the
compressor as allowed



what controls the operation of a high-side float? - CORRECT ANSWERS.✔️✔️the condenser, and
receiver



when suction pressure decreases,compressor capacity - CORRECT ANSWERS.✔️✔️decreases



cooling-tower water should be maintained at a p h near - CORRECT ANSWERS.✔️✔️7.8



the sub cooling effect of the liquid refrigerant just before the expansion valve causes increased -
CORRECT ANSWERS.✔️✔️refrigeration effect



sub cooling the liquid refrigerant just before the expansion valve, results in an increase in - CORRECT
ANSWERS.✔️✔️refrigeration effect



what percent of oil travels with the refrigerant? - CORRECT ANSWERS.✔️✔️10 percent



any water present in the refrigerant side of a freon refrigeration system causes a - CORRECT
ANSWERS.✔️✔️frozen expansion valve

, when heated, R-12 changes to - CORRECT ANSWERS.✔️✔️phosgene gas



in an absorption system, the medium normally used to vaporize refrigerant and increase its temperature
is - CORRECT ANSWERS.✔️✔️steam



which does not increase the capacity of a water-cooled condenser? - CORRECT
ANSWERS.✔️✔️decreasing the ambient temperature



when energizing a solenoid valve, to close the valve, its position would normally be - CORRECT
ANSWERS.✔️✔️normally open



a valve that does not restrict flow is the - CORRECT ANSWERS.✔️✔️solenoid valve



the oil separator is located on the - CORRECT ANSWERS.✔️✔️discharge line, as far from the compressor
as possible



when we say a refrigerant is anhydrous, we mean - CORRECT ANSWERS.✔️✔️water is absent



the primary purpose of a purger, in a freon system is the removal of - CORRECT
ANSWERS.✔️✔️noncondensables



operating a freon air-conditioning unit with the filters clogged, is likely to result in - CORRECT
ANSWERS.✔️✔️low suction pressure



a refrigerant overcharge would - CORRECT ANSWERS.✔️✔️increase head pressure



on the most common three-phase, four-wire service, the voltage between any phase and neutral should
be - CORRECT ANSWERS.✔️✔️120 volts



the following statement about brine is true - CORRECT ANSWERS.✔️✔️p h should be slightly alkaline at
7.8

Escuela, estudio y materia

Institución
Ammonia refigdweration
Grado
Ammonia refigdweration

Información del documento

Subido en
3 de abril de 2025
Número de páginas
9
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$16.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
Sinzorah

Conoce al vendedor

Seller avatar
Sinzorah Havard School
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1
Miembro desde
2 año
Número de seguidores
0
Documentos
318
Última venta
7 meses hace

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes