1. A refrigerant line contains Ammonia at the following conditions: 80F, 120 PSIG - CORRECT ANSWERS.️️The line contains vapor 2. A low temperature Ammonia booster compressor normally operates with a discharge temperature of 120F. The temperature of the discharge vapor suddenly drops to 80F. What is indicated? - CORRECT ANSWERS.️️There is possibly liquid in the suction line 3. Where can oil be drained from an Ammonia system - CORRECT ANSWERS.️️All the above 4. the high pressure receiver, the low pressure receiver, oil pots and some evaporators 5. for each pound of water evaporated, an evaporative condenser rejects - CORRECT ANSWERS.️️970 to 1057 BTU's 6. A back pressure regulator is - CORRECT ANSWERS.️️a pressure controller 7. The pressure/ temperature relationship for ammonia, obtained from a PT chart, is only valid when the ammonia in the section you are metering is - CORRECT ANSWERS.️️in a saturated condition 8. An ammonia liquid line has liquid trapped and it's temp is starting to rise. How much will the PSIG pressure rise for every one degree F of heat exposure? (hydrostatic pressure increase) - CORRECT ANSWERS.️️100 to 150 psi

Mostrar más Leer menos
Institución
GCAP 2023
Grado
GCAP 2023









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
GCAP 2023
Grado
GCAP 2023

Información del documento

Subido en
3 de abril de 2025
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

GCAP 2023 ASSESMENT TEST WITH
CORRECT QUESTIONS AND ANSWERS.

1. A refrigerant line contains Ammonia at the following conditions: 80F, 120 PSIG - CORRECT
ANSWERS.✔️✔️The line contains vapor



2. A low temperature Ammonia booster compressor normally operates with a discharge
temperature of 120F. The temperature of the discharge vapor suddenly drops to 80F. What is
indicated? - CORRECT ANSWERS.✔️✔️There is possibly liquid in the suction line



3. Where can oil be drained from an Ammonia system - CORRECT ANSWERS.✔️✔A ️ ll the above
4. the high pressure receiver, the low pressure receiver, oil pots and some evaporators



5. for each pound of water evaporated, an evaporative condenser rejects - CORRECT
ANSWERS.✔️✔️970 to 1057 BTU's



6. A back pressure regulator is - CORRECT ANSWERS.✔️✔️a pressure controller



7. The pressure/ temperature relationship for ammonia, obtained from a PT chart, is only valid
when the ammonia in the section you are metering is - CORRECT ANSWERS.✔️✔️in a saturated
condition



8. An ammonia liquid line has liquid trapped and it's temp is starting to rise. How much will the
PSIG pressure rise for every one degree F of heat exposure? (hydrostatic pressure increase) -
CORRECT ANSWERS.✔️✔️100 to 150 psi



9. How are temperature and heat related - CORRECT ANSWERS.✔️✔️temperature is a measure of
the intensity of the heat in an object



10. what fluid friction or vapor resistance sometimes known as line loss or pressure drop - CORRECT
ANSWERS.✔️✔️the loss of pressure as the fluid/ vapor interacts with inner walls of the pipe

, 11. in a recirculation system where is it important to keep a constant pump pressure - CORRECT
ANSWERS.✔️✔️at the metering valve evaporator inlet



12. A home air conditioner is rated to remove 24,000 BTU's in 1 hour. What is its tonage - CORRECT
ANSWERS.✔️✔️2 ton



13. what is the king valve - CORRECT ANSWERS.✔️✔️first liquid manual closing valve leaving the
HPR



14. calculate the compression ratio from the following information:
15. suction pressure 33 PSIG Discharge Pressure 181 PSIG - CORRECT ANSWERS.✔️✔️4.10:1



16. What pressure scale must be used to calculate a compression ratio - CORRECT
ANSWERS.✔️✔️PSIA



17. Approximately how many BTU's does it take to convert 1 pound of liquid water at 212F to steam
at 212F - CORRECT ANSWERS.✔️✔️970 BTU's



18. Approximately how many BTU's does it take to melt one pound of ice to water at 32F - CORRECT
ANSWERS.✔️✔️144 BTU's



19. An example of how a lava lamp works would be an example of what type of heat transfer -
CORRECT ANSWERS.✔️✔️All the above: Radiant, conduction, convection



20. what is specific heat (Cp) - CORRECT ANSWERS.✔️✔️it is the exact amount of heat that must be
transferred to change 1 pound of a substance by 1F



21. where should a superheated gas exist in all refrigeration systems - CORRECT
ANSWERS.✔️✔️inlet of compressor



22. where is the worst place to have a leak - CORRECT ANSWERS.✔️✔️high side liquid
$13.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
Sinzorah

Conoce al vendedor

Seller avatar
Sinzorah Havard School
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1
Miembro desde
1 año
Número de seguidores
0
Documentos
318
Última venta
1 mes hace

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes