Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

MRI In Practice Chapter 2 Best Exam Solutions Guaranteed Success.

Puntuación
-
Vendido
-
Páginas
6
Grado
A+
Subido en
01-04-2025
Escrito en
2024/2025

Parameters that cannot be changed because they are inherent to the body's tissue - correct answer intrinsic contrast parameters Name the MRI intrinsic contrast parameters - correct answer T1 recovery time, T2 decay time, proton density, flow, apparent diffusion coefficient or ADC Parameters that can be changed, all selected at the operator console, selection depends on the pulse sequence used - correct answer extrinsic contrast parameters Name the MRI extrinsic contrast parameters - correct answer TR, TE, flip angle, TI, turbo factor/echo train length, b value An MRI image has contrast if there are areas of ______ signal or white on the image and areas of _______ signal or dark on the image - correct answer high, low Some areas have an intermediate signal and will display what? - correct answer shades of gray in between black and white The ________ can be separated into the individual vectors or quantities of the tissue present in the patient such as fat, CSF and muscle - correct answer NMV A tissue has a high signal if it has a large ____________ component of coherent magnetization at the time of TE - correct answer transverse If a tissue has a small transverse component of coherent magnetization at time _______ it will return a small signal, resulting in a _______ area on the image - correct answer TE, dark Images obtain contrast mainly through the mechanisms of what? - correct answer T1 recovery, T2 decay and proton or spin density The number of mobile hydrogen protons per unit volume of that tissue - correct answer proton density Water - correct answer Molecules are spaced apart in there and molecular tumbling rate is relatively fast Fat - correct answer Large molecules closely packed together and who is molecular tumbling rate is relatively slow Fat - correct answer Has a low inherent energy and can easily absorb energy into its lattice from hydrogen nuclei Fat - correct answer The NMV of _______ realigns rapidly with B0 so the T1 time of this is short Water - correct answer Has a high inherent energy and cannot easily absorb energy into its lattice from hydrogen nuclei Water - correct answer The NMV of _______ takes longer to realign with B0 so the T1 time of this is long Short - correct answer The T2 decay process in the hydrogen in fat is efficient because the molecules are closely packed together and therefore spin spin interactions are more likely to occur. As a result spins dephase rapidly and the loss of transverse magnetization is rapid. The T2 time of fat is therefore ________ Long - correct answer T2 decay in water is less efficient than in fat, as the molecules are spaced apart and spin spin interactions are less likely to occur. As a result, spins dephase slowly and the loss of transverse magnetization is gradual. The T2 time of water is therefore __________ Fat - correct answer What has a high signal and appears bright on a T1 contrast image? Water - correct answer What has a low signal and appears dark on a T1 contrast image? T1 weighted images - correct answer On what type of image does fat appear bright and water appear dark? Water - correct answer What has a high signal and appears bright on a T2 contrast image? Fat - correct answer What has a low signal and appears dark on a T2 contrast image? T2 weighted images - correct answer On what type of image does water appear bright and fat appear dark? High - correct answer Tissues with a _________ proton density have a large transverse component of magnetization Low - correct answer Tissues with a _________ proton density have a small transverse component of magnetization proton density weighting - correct answer What is always present and depends on the patient and the area being examined. It is the basic MRI contrast Fat - correct answer

Mostrar más Leer menos
Institución
MRI IN PRACTICE
Grado
MRI IN PRACTICE

Vista previa del contenido

MRI In Practice Chapter 2

Parameters that cannot be changed because they are inherent to the body's tissue - correct answer
intrinsic contrast parameters



Name the MRI intrinsic contrast parameters - correct answer T1 recovery time, T2
decay time, proton density, flow, apparent diffusion coefficient or ADC



Parameters that can be changed, all selected at the operator console, selection depends on the pulse
sequence used - correct answer extrinsic contrast parameters



Name the MRI extrinsic contrast parameters - correct answer TR, TE, flip angle, TI,
turbo factor/echo train length, b value



An MRI image has contrast if there are areas of ______ signal or white on the image and areas of
_______ signal or dark on the image - correct answer high, low



Some areas have an intermediate signal and will display what? - correct answer
shades of gray in between black and white



The ________ can be separated into the individual vectors or quantities of the tissue present in the
patient such as fat, CSF and muscle - correct answer NMV



A tissue has a high signal if it has a large ____________ component of coherent magnetization at the
time of TE - correct answer transverse



If a tissue has a small transverse component of coherent magnetization at time _______ it will return a
small signal, resulting in a _______ area on the image - correct answer TE, dark



Images obtain contrast mainly through the mechanisms of what? - correct answer T1
recovery, T2 decay and proton or spin density

, The number of mobile hydrogen protons per unit volume of that tissue - correct answer
proton density



Water - correct answer Molecules are spaced apart in there and molecular tumbling
rate is relatively fast



Fat - correct answer Large molecules closely packed together and who is molecular
tumbling rate is relatively slow



Fat - correct answer Has a low inherent energy and can easily absorb energy into its
lattice from hydrogen nuclei



Fat - correct answer The NMV of _______ realigns rapidly with B0 so the T1 time of
this is short



Water - correct answer Has a high inherent energy and cannot easily absorb energy
into its lattice from hydrogen nuclei



Water - correct answer The NMV of _______ takes longer to realign with B0 so the
T1 time of this is long



Short - correct answer The T2 decay process in the hydrogen in fat is efficient
because the molecules are closely packed together and therefore spin spin interactions are more likely
to occur. As a result spins dephase rapidly and the loss of transverse magnetization is rapid. The T2 time
of fat is therefore ________



Long - correct answer T2 decay in water is less efficient than in fat, as the molecules
are spaced apart and spin spin interactions are less likely to occur. As a result, spins dephase slowly and
the loss of transverse magnetization is gradual. The T2 time of water is therefore __________



Fat - correct answer What has a high signal and appears bright on a T1 contrast
image?

Escuela, estudio y materia

Institución
MRI IN PRACTICE
Grado
MRI IN PRACTICE

Información del documento

Subido en
1 de abril de 2025
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$13.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
RealGrades Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
192
Miembro desde
2 año
Número de seguidores
52
Documentos
12259
Última venta
4 días hace

4.0

26 reseñas

5
12
4
5
3
7
2
1
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes