NEC Questions and Answers 100% Solved Conduit syatems passing from an enclosure or room that is unclasssified as a result of pressurization into a _______________ location shall not require a seal at the boundary. 501.15 (2) Correct Answ_Class I - Division 2 In a completed seral, the minimum thickness of the sealing shall in no case be less than __________ inch. 501.15 (c)(3) Correct Answ_5/8

Mostrar más Leer menos
Institución
NEC ...
Grado
NEC ...

Vista previa del contenido

NEC Questions and Answers 100% Solved


Conduit syatems passing from an enclosure or room that is unclasssified as a result of

pressurization into a _______________ location shall not require a seal at the boundary.


501.15 (2) Correct Answ_Class I - Division 2




In a completed seral, the minimum thickness of the sealing shall in no case be less than

__________ inch.


501.15 (c)(3) Correct Answ_5/8




Cable passing from an enclosure or room that is unclassified as a result of type z pressurization

into a ____________ shall not require a seal at the boundary.


501.17 (e) Correct Answ_Class I - Division 2




Elecctrically heated utilization equipment shall not exceed _________ percent of the ignition

temperature in degree of the gas or vapor.


501.135 Correct Answ_80

,In industrial establishments with limited public access, where the conditins of maintance and

supervision ensure that only qualified persons service the installation of type ________ cable

shall be permitted.


501.10 (3) Correct Answ_MC




An electrical component that does not generate more than 1.5 volts, 100 milliamps, and 25 mill-

watts is a _____________.


504.2 Correct Answ_simple apparatus




________________ apparatus, as described on the control drawing, shall not be required to be

listed.


504.4 Correct Answ_simple




In class I Division 2 location where the enforcing agency determines that there is mechanical

ventilation providing a minimum of ______________ air change per hour.


511.3 (c)(1) Correct Answ_4




Any pit or pedression below floor level shall be considered to be a ____________ location.


511.3 (c)(3) Correct Answ_Class I - Division 1

,Arc equipment that is less _________ feet above the floor level and that may produce arcs,

sparks, or particles of hot metal.


511.7 (b)(1)(a) Correct Answ_12




Lamps and lamp-holder for fixed lighting that is located over lanes through which vehicles are

commonly driven shall not be less than ________ feet above the floor level.


511.7(b)(1)(b) Correct Answ_12




Where electrical diagnostic equipment are to be used it shall have _____________ protection for

personal.


511.12 Correct Answ_GFI




Areas not cut off for ventilation from aircraft hanger, shallbe classified as a _________________

or zone 2 location up to a level of 18 inches above the ground.


513.3(b) Correct Answ_Class I - Division 2




In Class I - Division 2 at motor fuel dispensing facilities or commercial garages the distance shall

have least _______ feet of ant edge, extending in any direction.

, 514.3 (B)(2) Correct Answ_5




Emergency control shall be installed at a location acceptable by the authority having jurisdiction,

by the control shall be more than ________ feet from the dispensers and emergency controls

shall shut off all power to all dispensing equipment.


514.11 (C) Correct Answ_20




Underground wiring shall be installed in threaded rigid metal conduit or threaded stell

intermediate metal conduit or, where buried under not less than _______ feet.


515.8 Correct Answ_2




For spraying operations confined to an enclosed spray booth or room, the space within

_________ feet in any direction from any opening shall be considered Class 1 or Class 2


516.3 (4) Correct Answ_3




A subsystem of the emergency system consisting of feeders and branch circuits is a

_____________.


517.2 Correct Answ_life safely branch

Escuela, estudio y materia

Institución
NEC ...
Grado
NEC ...

Información del documento

Subido en
29 de marzo de 2025
Número de páginas
36
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$15.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
ARVEX

Documento también disponible en un lote

Conoce al vendedor

Seller avatar
ARVEX stuvia
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
7
Miembro desde
10 meses
Número de seguidores
0
Documentos
2867
Última venta
2 meses hace

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes