100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

NEC 2017 Questions and Answers 100% Solved

Puntuación
-
Vendido
-
Páginas
23
Grado
A+
Subido en
29-03-2025
Escrito en
2024/2025

NEC 2017 Questions and Answers 100% Solved How many volt-amperes are calculated per 1ft of show window? A) 50 B) 100 C) 150, or D) 200 Correct Answ_D) 200 220.14(G)(2) Metal enclosures for over current devices in damp or wet locations, shall be mounted so that there is at least a ________in. air gap between the wall and the other support surface. A) 1/8 B) 1/4 C) 3/8, or D) 1/2. Correct Answ_B) 1/4 240.32, 312.2

Mostrar más Leer menos
Institución
NEC ...
Grado
NEC ...

Vista previa del contenido

NEC 2017 Questions and Answers 100%
Solved

How many volt-amperes are calculated per 1ft of show window?


A) 50 B) 100 C) 150, or D) 200 Correct Answ_D) 200 220.14(G)(2)




Metal enclosures for over current devices in damp or wet locations, shall be mounted so that

there is at least a ________in. air gap between the wall and the other support surface.


A) 1/8 B) 1/4 C) 3/8, or D) 1/2. Correct Answ_B) 1/4 240.32, 312.2




A lamp holder is supplied by a circuit over 20 amps. What type of lamp holder is permitted?


A) Medium base B) Light duty C) Heavy duty, or D) Extra heavy duty. Correct Answ_C)

Heavy duty 210.21(A)




General lighting loads by occupancy dwelling units require a minimum of ______ volt-amperes

per sq. ft.


A) 3 B) 4 C) 5 or D) 8 Correct Answ_A) 3 volt amperes Table 220.12

,Surge arresters are grounded at the arrester grounding terminal. If the arrester ground conductor

is ran in a metal enclosure, the grounding conductor MUST be bonded at ______end(s) of the

enclosure.


A) one B) the supply C) the load D) both Correct Answ_D) Both 280.25




How many receptacle outlets are required above a show window that is 18ft wide?


A) 2 B) 3 C)4 or D) none of the above Correct Answ_A) 2 210.62




Concrete encased grounding electrodes shall have a minimum length of _______ft and minimum

diameter of ________in.


A) 10ft and 1/2 inch B) 15ft and 5/8 inch C) 20ft and 1/2 inch, or D) 25ft and 5/8 in. Correct

Answ_C) 20 feet and 1/2 inch diameter. 250.52(A)(3)(1)




A grounding electrode shall be installed so ______ft in contact with soil. (Earth)


A) 6 B) 8 C) 10 or D) 15 Correct Answ_8 ft 250.53(G)




What is the maximum combined length of FMC, FMT, and LFMC in the same ground-fault

current path.


A) 4ft B) 5ft C) 6ft D) 10ft Correct Answ_250.118(5)(C)

, Appliance outlets (such as electric dryers) shall be installed within _____ft of intended appliance

location.


A) 2 B) 6 C) 8 or D)10 Correct Answ_B) 6 210.50(C)




Overhead service drops shall NOT have conductors smaller than?


A) #8 Copper B) #4 Aluminium C) #6 Copper, or D) #4 Copper Correct Answ_A) 8AWG

copper 230.23(B)




A 10ft section of ______ is not considered a grounding conductor.


A) AC Cable B) Cable tray C) FMC D) Auxiliary gutter Correct Answ_C) FMC

250.118(5)(C)




Service entrance conductors in a raceway beneath a building, under at least _____ inches of

concrete is considered to be "outside" the building.


A) 2 B) 4 C) 8 D) 12 Correct Answ_A) 2 230.6(1)




The two small appliance branch circuits in dwellings need to be calculated at _______volt

amperes. (Watts)

Escuela, estudio y materia

Institución
NEC ...
Grado
NEC ...

Información del documento

Subido en
29 de marzo de 2025
Número de páginas
23
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$12.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
ARVEX

Documento también disponible en un lote

Conoce al vendedor

Seller avatar
ARVEX stuvia
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
7
Miembro desde
10 meses
Número de seguidores
0
Documentos
2867
Última venta
2 meses hace

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes