Virginia hic Exam Questions with correct Answers The MINIMUN length drywall screw for installing 1/2 inch gypsum board to wood studs is - ANSWER- 1 1/4 inches What is the MINIMUM breaking strength required of safety belt lanyards - ANSWER- 5,400 pounds What is the MINIMUM clearance that combustible insulation MUST other heat-producing devices - ANSWER- 1 inch What is the MAXIMUM flame spread index for insulation materials - ANSWER- 25 The amount of water per sack of cement is what controls all EXCEPT - ANSWER- Wear resistance

Vista previa del contenido

Virginia hic Exam Questions with correct Answers
The MINIMUN length drywall screw for installing 1/2 inch gypsum board to wood studs
is - ANSWER- 1 1/4 inches

What is the MINIMUM breaking strength required of safety belt lanyards - ANSWER-
5,400 pounds

What is the MINIMUM clearance that combustible insulation MUST other heat-
producing devices - ANSWER- 1 inch

What is the MAXIMUM flame spread index for insulation materials - ANSWER- 25

The amount of water per sack of cement is what controls all EXCEPT - ANSWER- Wear
resistance

The escape device for a trench over 4 feet deep MUST be within a MAXIMUM of -
ANSWER- 25 feet of the worker

What is the correct sequence for installing a bi-fold door - ANSWER- Top track, lower
track, insert bottom pivot, insert upper pivot

What is the MINIMUM height for a stairway handrail - ANSWER- 34 inches

How MUST rafters be framed to each other - ANSWER- With rectangular ties

The nailing holes in aluminum and vinyl siding are elongated to allow for - ANSWER-
Expansion and contraction

What are batter boards - ANSWER- stakes and ledger boards marking building lines

The first step that needs to be taken prior to starting any excavation work is - ANSWER-
contracting the local utility companies

What is the MAXIMUM distance horizontal reinforcement can be placed from the top of
a masonry partition wall - ANSWER- 16 inches

What is the MINIMUM vertical reinforcement spacing for a reinforced concrete
foundation wall that is 7 feet high and 10 inches thick on type SP soil - ANSWER- 48
inches on center

, A third stairway stringer should be used when the stair width exceeds - ANSWER- 30
inches

Unless otherwise specified, the standard guideline for spacing contraction joints is to
space them in feet - ANSWER- 2 times the stab depth in inches

What is the MINIMUM lap of riveted horizontal lap siding - ANSWER- 1 inches

For multiple-width masonry (mampostería de ancho múltiple) what is the MINIMUM
thickness of grout between masonry units and reinforcements? - ANSWER- 1/4 inch

What is the MAXIMUM dimension of the ventilation coverings for under-floor space -
ANSWER- 1/4 inch

The MOST specific information about the size and location of windows would be found
in a - ANSWER- Floor plan

What is the MINIMUM illumination for general constructions area lighting - ANSWER- 5
foot candles

in drywall 3 trim is used to - ANSWER- provide a finish edge

What is the MINIMUM number of anchor bolts REQUIRED for anchoring a 12 foot
section of wood still plate to a foundation - ANSWER- two bolts

What is the MINIMUM square footage of net clear opening area for an egress window in
a second floor sleeping area - ANSWER- 5.70 square feet

Which window type consists of an upper and a lower sash that slide vertically in the side
jambs - ANSWER- Double hung windows

Damp proofing on below-grade masonry foundation walls shall extend from the top of
the footing to - ANSWER- 6 inches above the finished grade

Scaffolds MUST remain a MINIMUM of how many feet from a 50-kV power line -
ANSWER- 10 feet

The REQUIREMENT for the thickness of masonry unit bed joints for the second course
shall be - ANSWER- 3/8 inches

Información del documento

Subido en
29 de marzo de 2025
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$11.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TestShield
5.0
(218)
Vendido
269
Seguidores
6
Artículos
803
Última venta
3 horas hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes