Massachusetts oil burner study guide 2024 COMPLETE EXAM QUESTIONS AND VERIFIED ANSWERS| 100% ACCURATE SOLUTIONS|ALREADY GRADED A+
Massachusetts oil burner study guide 2024 COMPLETE EXAM QUESTIONS AND VERIFIED ANSWERS| 100% ACCURATE SOLUTIONS|ALREADY GRADED A+ What is the voltage found at the TT terminals - Answer24 volts What are the 8 steps of a no heat call - Answer1 talk to customer 2 check tt.3 check to make sure an emergency switch is on 4check to make sure there is oil in the tank 5 check to make sure the main power going to the unit is on six check to make sure that tank shut off valve is open 7 know whether the tank is located above or below the burner I know the type and style of the system that is being used on a one or two pipe system What is a cad cell - AnswerA device containing condominium sulfide used to prove the flame in oil burner furnace How much air is needed to burn a gallon of number 2 fuel oil and why. - AnswerIn 2015 most oil burners are set up to burn with approximately 50% excess air because it would be dangerous to set up a burner for exactly the correct amount of air What is the term InStep mean - AnswerThe stack relay is operating correctly What is normal pump pressure - Answer100 PSI How is combustion achieved - AnswerAtomization, air, ignition. What is primary air and secondary air - AnswerPrimary air, air that is introduced to a furnace burner before the combustion process has taken place. secondary air, air that is introduced to the furnace after combustion has taken place and that supports combustion How should an oil tank be supported - AnswerIt shall be secured attached to a non-combustible supports What is the wire gauge use an oil burner circuits - Answer14 gauge 15 amp fuse How is an oil burner wired - AnswerShall be wired on its own circuit. All protective control and emergency devices shall be series connected in the grounded line conductors. all the electrical wiring shall be in accordance with 527 CMR 12.00 Massachusetts electrical code What size vent pipe is required with a 2 inch fill pipe - AnswerA fill pipe shall not be greater than the vent pipe. The minimum the fill pipe in the state of Massachusetts is one and one quarter inch. Explain interrupted ignition - Answerthe ignition Transformer drops out of the circuit once a flame is established What are the elements are found in fuel oil number 2 - AnswerCarbon hydrogen oxygen and hydrocarbons What is a BTU - AnswerA British thermal unit is the amount of heat needed to raise one pound of water 1 degree Fahrenheit How many BTUs are in one gallon number 2 fuel oil - Answer140,000 BTUs
Escuela, estudio y materia
- Institución
- Massachusetts oil burner
- Grado
- Massachusetts oil burner
Información del documento
- Subido en
- 21 de marzo de 2025
- Número de páginas
- 13
- Escrito en
- 2024/2025
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
what is a cad cell
-
what is normal pu
-
what is the voltage found at the tt terminals
-
what are the 8 steps of a no heat call
-
how much air is needed to burn a gallon of number
-
what is the term instep mean