170 °F - Hydraulic system components shall not be installed in areas where operating temperature exceeds _____ °F D. Vessel Type (sail v. power) - On a mechanical cable over sheave steering system, attachment of the cable clamps (bulldog) must take into account all of the following EXCEPT: A. Cable Size B. Orientation of the clamp C. Location of the clamp D. Vessel Type (sail v. power) -22 °F to +158 °F - What is the design operating temperature range for CO detectors? No longer than 6 minutes - If a CO detector alarm can be muted, for how long will the mute last? True - T or F: A CO detector must be installed on all boats with an enclosed accommodation space C. Propeller material - Which of the following is NOT considered when installing a new bow thruster? A. Over-current protectionB. Battery disconnect switch C. Propeller material D. Bonding D. is supplied by a circuit that uses a fuse or lock-out equipped circuit breaker - According to ABYC A-24, a CO monitor should be installed so that it:

Mostrar más Leer menos
Institución
ABYC Systems Certification
Grado
ABYC Systems Certification











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ABYC Systems Certification
Grado
ABYC Systems Certification

Información del documento

Subido en
18 de marzo de 2025
Número de páginas
42
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

307 ABYC Systems Certification
Exam Review
170 °F - ✔ ✔ Hydraulic system components shall not be installed in
areas where operating temperature exceeds _____ °F

D. Vessel Type (sail v. power) - ✔ ✔ On a mechanical cable over
sheave steering system, attachment of the cable clamps (bulldog) must
take into account all of the following EXCEPT:



A. Cable Size

B. Orientation of the clamp

C. Location of the clamp

D. Vessel Type (sail v. power)

-22 °F to +158 °F - ✔ ✔ What is the design operating temperature
range for CO detectors?

No longer than 6 minutes - ✔ ✔ If a CO detector alarm can be
muted, for how long will the mute last?

True - ✔ ✔ T or F: A CO detector must be installed on all boats with
an enclosed accommodation space

C. Propeller material - ✔ ✔ Which of the following is NOT
considered when installing a new bow thruster?

A. Over-current protection

,B. Battery disconnect switch

C. Propeller material

D. Bonding

D. is supplied by a circuit that uses a fuse or lock-out equipped circuit
breaker - ✔ ✔ According to ABYC A-24, a CO monitor should be
installed so that it:

A. can be turned off and on with the main electrical panel supply
breaker

B. can be equipped with an on/off switch

C. can never be turned off

D. is supplied by a circuit that uses a fuse or lock-out equipped circuit
breaker

C. Type of Vessel (sail or power) - ✔ ✔ When installing a windlass,
considerations should be given to all of the following EXCEPT:

A. Overcorrect protection

B. Battery disconnect switch

C. Type of Vessel (sail or power)

D. Deck construction and support

Class A Fire - ✔ ✔ What type of fire (class A, B or C) occurs with
combustible materials such as wood, cloth, paper, rubber, FRP, etc?

Class C Fire - ✔ ✔ What type of fire occurs in energized electrical
equipment? (Class A,B or C)

,Class B Fire - ✔ ✔ What type of fire occurs with flammable liquid,
oils, grease, and gasses? (Class A,B or C)

True - ✔ ✔ T or F: Boats under 26 feet may be equipped with a
bucket on a lanyard in lieu of a Class A fire extinguisher.

True - ✔ ✔ T or F: Diesel machinery (engines, generators, and
blowers) installed in protected spaces on gasoline boats shall be
automatically shut down upon discharge of a fixed fire extinguishing
system.

3 (outside engine compartment, steering position, and galley or
passenger cockpit) - ✔ ✔ How many portable (USCG Type B-1) fire
extinguishers must be present on a boat which is between 26' and 40'
in length?

A-4 (table IV) - ✔ ✔ What ABYC standard lists minimum clean agent
fire extinguisher sizes for flooding various engine compartment sizes?

True - ✔ ✔ T or F: Water is likely to be the most effective
extinguishing agent for Type "A" fires

True - ✔ ✔ T or F: when drenching a type A fire, it is recommended
to open up the combustibly material to expose during embers and re-
drench or throw overboard.

A. Engine compartment volume - ✔ ✔ Which of the following are
important when selecting a permanently installed engine room gaseous
fire-extinguishing system?

A. Engine compartment volume

B. Horsepower

, C. Fuel type

D. Hull material

Dial Indicator - ✔ ✔ What tool is used to measure shaft run-out

Micrometer or Caliper - ✔ ✔ What tool is used to measure wire
rope size or shaft diameter?

1 Bar = 14.7 PSI - ✔ ✔ What is atmospheric pressure at sea level in
bar and PSI?

True - ✔ ✔ T or F: Gasoline fuel tanks may not be integral with hull
or boat structure, but diesel tanks may.

Must be less than 20 gallons, cylindrical with a domed head. - ✔ ✔
If a gasoline tank is made of stainless steel, what are the ABYC
requirements for the design of such a tank?

American Standard Taper Pipe Thread (NPTF) - ✔ ✔ What standard
is to be used for threaded connections into a gasoline fuel tank?

500 - 600 microns - ✔ ✔ What is ther allowable range (in microns)
for a fuel strainer installed at the end of a pick-up line inside a gasoline
fuel tank?

Must isolate non-galvanically compatible materials with 300 series
stainless steel bushing. - ✔ ✔ What precaution must be undertaken
when installing a brass fitting into an aluminum fuel tank?

True - ✔ ✔ T or F: It is permissible to use the grounded conductor
from a fuel tank sender unit as the grounding (bonding) conductor for
the tank.
$10.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
jackline98 Stanford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
262
Miembro desde
2 año
Número de seguidores
152
Documentos
9862
Última venta
2 días hace

Here you will find different past papers with correct and updated solutions .Please do not forget to leave a review after purchasing any document .Goodluck and success in advance.

3.3

60 reseñas

5
20
4
11
3
9
2
5
1
15

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes