JOURNEYMAN ELECTRICIAN PRACTICE TEST|| 50 ACTUAL QUESTIONS WITH VERIFIED SOLUTION 2025|| RATED A+ 1. Conductors with marked on the insulation are NOT approved for use in a wet location.: THHN conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. 2. Given: A one-family dwelling unit with a demand load of 200 amperes is sup- plied with a 120/240 volt, single-phase, electrical system from the local utility company. What is the MINIMUM size aluminum THW conductors required for use as service-entrance conductors for this residence?: 4/0 AWG one-family dwelling 120/240 volt, single-phase, service-entrance conductors to be sized at an ampacity of not less than 83% of the service rating. Therefore, 200 amperes x 83% = 166 amperes; size 4/0 AWG THW aluminum conductors with an allowable ampacity of 180 amperes should be selected for this dwelling. 3. Where a 150 kVA, single-phase transformer having a secondary voltage of 120/240 is installed at a multi-family dwelling, the full-load current rating, in amperes, of the secondary is .: 625 amperes

Mostrar más Leer menos
Institución
Master Electrical
Grado
Master Electrical

Vista previa del contenido

1. Conductors with marked on the insulation are NOT approved for use
in a wet location.: THHN

conductors with THHN insulation are approved for use in dry and damp locations
only and conductors with THWN, THHW, and THW insulation are recognized for use
in dry and wet locations.
2. Given: A one-family dwelling unit with a demand load of 200 amperes is sup-
plied with a 120/240 volt, single-phase, electrical system from the local utility
company. What is the MINIMUM size aluminum THW conductors required for
use as service-entrance conductors for this residence?: 4/0 AWG

one-family dwelling 120/240 volt, single-phase, service-entrance conductors to be
sized at an ampacity of not less than 83% of the service rating. Therefore, 200
amperes x 83% = 166 amperes; size 4/0 AWG THW aluminum conductors with an
allowable ampacity of 180 amperes should be selected for this dwelling.
3. Where a 150 kVA, single-phase transformer having a secondary voltage of
120/240 is installed at a multi-family dwelling, the full-load current rating, in
amperes, of the secondary is .: 625 amperes

To find the full-load current rating of the single-phase transformer apply the sin-
gle-phase current formula as shown:I = (150 kVA x 1000) / 240 volts = 15,000/240
= 625 amperes
4. Which one of the following listed circuit breakers is NOT a standard ampere
rating?: 75 amperes

the standard ampere ratings for fuses and circuit breakers. A circuit breaker with an
ampere rating of 75 amperes is not a standard ampere rating.
5. The MINIMUM length of free conductor to be left at each junction box for
the purpose of splicing conductors, or making connections to illuminares or

, devices shall be .: 6 inches

free conductor is to be left at each junction box for splices or the connection of
luminaires or devices. The intent of this rule is to ensure enough conductor slack for
the terminal connections or splices to be made easily.
6. In general, overhead service-drop conductors shall NOT be smaller than
.: 8 AWG copper

overhead service-drop conductors to be not smaller than 8 AWG copper or 6
AWG aluminum or copper-clad aluminum. Do not get service-drop conductors, the

Escuela, estudio y materia

Institución
Master Electrical
Grado
Master Electrical

Información del documento

Subido en
14 de marzo de 2025
Número de páginas
12
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$14.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MBOFFIN HOWARD COMMUNITY COLLEGE
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
736
Miembro desde
5 año
Número de seguidores
218
Documentos
5601
Última venta
2 días hace
MBOFFIN STORES.

3.7

125 reseñas

5
55
4
20
3
25
2
9
1
16

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes