fire alarm exam questions with actual solutions 2025.

Institución
OHIO FIRE ALARM
Grado
OHIO FIRE ALARM









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
OHIO FIRE ALARM
Grado
OHIO FIRE ALARM

Información del documento

Subido en
11 de marzo de 2025
Número de páginas
10
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

fire alarm exam questions with actual
solutions 2025.




A building or tenant space used for assembly purposes with an occupant load of less
than 50 persons shall be classified as a group B occupancy - ANSWER: true

should indicates a mandatory requirement - ANSWER: false

smoke detectors may directly release smoke doors as long as it is listed for releasing
service - ANSWER: true

fire alarm signals shall take precedence over all over signals - ANSWER: true

in a high rise building, the system shall operate a minimum of the alarming floor and 2
floors above - ANSWER: false

exit stair enclosures and passageways shall contain visible signals for evacuation. -
ANSWER: false

a protective cover that emits a local alarm signal is permissible - ANSWER: false

movement of water due to waste, surges. or variable pressure shall not initiate an alarm
signal - ANSWER: true

optical fiber cables are permitted to be installed as part of the fire alarm system -
ANSWER: true

where fire alarm systems are not monitored by a supervising station, an approved
permanent sign shall be installed adjacent to each manual for alarm box that reads:
"WHEN ALARM SOUNDS CALL FIRE DEPARTMENT". - ANSWER: true

when a fire alarm system is used for multiple buildings, each building shall be zoned
separately - ANSWER: true

, initiating devices are NOT permitted to be supported by their circuit conductors -
ANSWER: true

fire alarm signals shall be distinctive in sound from other signals, and their sound shall
not be used for any other purpose - ANSWER: true

evacuation signals are required in elevator cars - ANSWER: false

smoke detectors shall NOT be recessed into the mounting surface unless tested and
listed for that application - ANSWER: true

spaces beneath raised floors shall be considered as the same room - ANSWER: false

the ckt disconnect means for a fire alarm system shall have red identification and be
identified as:
a. DO NOT DISCONNECT
b. FIRE ALARM SYSTEM POWER
c. FIRE ALARM CIRCUIT
d. FIRE ALARM DISCONNECT - ANSWER: c. FIRE ALARM CIRCUIT

In a residential application, how many smoke detectors are required per floor
a. 1
b.2
c. no specific requirement, it is based on the location of the bedrooms - ANSWER: a. 1

The maximum air sample transport time from the farthest sampling port to the detector
shall not exceed
a. 10 seconds
b. 30 seconds
c. 120 seconds
d. 183 seconds - ANSWER: c. 120

which devices are required to be red in color
a. pull stations
b. Horn/Strobes
c. Strobes
d. All are required to be red - ANSWER: a. Pull stations

conducting a visual examination of a system to verify that it appears to be in operating
condition
$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
PageTurners Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
12
Miembro desde
1 año
Número de seguidores
0
Documentos
1615
Última venta
21 horas hace
WHITE ORCHID STORE

EXCELLENCY IN ACCADEMIC MATERIALS ie exams, study guides, testbanks ,case, case study etc

3.0

2 reseñas

5
0
4
0
3
2
2
0
1
0

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes