100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Fire Alarm 4 questions with actual answers 2025

Puntuación
-
Vendido
-
Páginas
5
Grado
A+
Subido en
11-03-2025
Escrito en
2024/2025

Fire Alarm 4 questions with actual answers 2025

Institución
OHIO FIRE ALARM
Grado
OHIO FIRE ALARM









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
OHIO FIRE ALARM
Grado
OHIO FIRE ALARM

Información del documento

Subido en
11 de marzo de 2025
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Fire Alarm 4 questions with actual
answers 2025.




A smoke detector cannot be installed in the following conditions unless rated for that
application. - ANSWER: ~Temperatures below 32 deg. F
~Temperatures above 100 deg. F
~Humidity above 93%
~Air velocity above 300 ft/min

The alert tone preceding any message may be a part of the voice message, but cannot
be transmitted automatically from a separate tone generator.
True or False - ANSWER: False

Effective January 1, 2002, the secondary power supply shall automatically supply the
energy to the system within twenty seconds of a power failure.
True or False - ANSWER: False

Smoke detectors listed or approved exclusively for door release service shall not be
used for open area protection.
True or False - ANSWER: True

What type of fire alarm system transmits alarms to a public fire service communications
center. - ANSWER: Municipal fire alarm system

Fire alarm signals and trouble alarms may have the same tone sound and
characteristics as long as the lenses are painted different colors.
True or False - ANSWER: False

Partitions which do not extend to the ceiling and are within less than 18 inches from the
ceiling are not considered to affect smoke travel and therefore do not warrant a
reduction of smoke detector spacing.
True or False - ANSWER: False

, When the distance between the ceiling and the top of a door is greater then 24 inches
NFPA states that you shall have one smoke detector on each side of the door.
True or False - ANSWER: True

The Ohio Basic Building Code requires installations .to conform to the requirements
outlined in NFPA 7, chapter 35
True or False - ANSWER: False

The mounting height for manual pull stations shall be between 3½ and 4½ feet.
True or False - ANSWER: True

Define Listed - ANSWER: Approved materials by authority having jurisdiction

Detectors that are not supported by their current carrying conductors are in violation of
NFPA 72.
True or False - ANSWER: False

The maximum allowable distance from a manual pull station to the nearest point of
egress is ____ - ANSWER: 5 feet

Audible notification devices shall be rated 15 db higher than the average noise level, or
5db higher than the maximum noise level in that room.
True or False - ANSWER: True

If two buildings are covered by the same fire alarm system they must be covered by the
same zone of origin.
True or False - ANSWER: False

Within how many seconds shall a trouble signal be returned to normal. - ANSWER: 200
Seconds

What type of photoelectric light obscuration smoke detector uses a beam to span an
area. - ANSWER: Projected beam detector

Installation of wiring, conduit, and equipment must be in accordance with NFPA 760.
True or False - ANSWER: True

Smoke detectors for door release service shall be: - ANSWER: ~Ionization
~Photoelectric

Duct detectors shall be mounted in a fixed position, monitored and recorded.
$11.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
PageTurners Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
12
Miembro desde
1 año
Número de seguidores
0
Documentos
1615
Última venta
21 horas hace
WHITE ORCHID STORE

EXCELLENCY IN ACCADEMIC MATERIALS ie exams, study guides, testbanks ,case, case study etc

3.0

2 reseñas

5
0
4
0
3
2
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes