Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 3 fuera de 20 páginas
Examen

NACE CIP 1 CBT EXAM PRACTICE QUESTIONS with solved solutions.

Document preview thumbnail
Vista previa 3 fuera de 20 páginas

NACE CIP 1 CBT EXAM PRACTICE QUESTIONS with solved solutions.

Vista previa del contenido

NACE CIP 1 CBT EXAM PRACTICE QUESTIONS
with solved solutions

Dew point is the temperature at which - ANSWER>>condensation occurs.

You are the NACE Inspector on a tank lining project where a 50% solids epoxy
tank lining is being applied. After application of the 19 coat you notice small
blisters in some areas of the applied lining. Your FIRST preferred course of action
is to: - ANSWER>>Document the problem and advise the Contractor and Owner's
representative.

If a contractor is using a poorly maintained compressor to supply air for abrasive
blast cleaning and conventional airspray, the coating inspector should perform a -
ANSWER>>blotter test for the presence of oil and water.

Upon arrival of coating materials, the inspector should - ANSWER>>observe and
document the amount of material and batch numbers.

Relative humidity is - ANSWER>>a measure of the amount of moisture in the air
compared to saturation level.

Galvanic corrosion occurs on which of the following substrates? -
ANSWER>>Metal



What is the minimum recommended distance away from an edge that an
inspector should take a measurement with a dial type magnetic pull off Dry Film
Thickness(DFT) gauge? - ANSWER>>2.5 cm (1 inch)

Polymerization is the process of? - ANSWER>>Monomers joining together.

,An exposed area of the substrate or previous coat of a conductive material, often
caused by poor application technique is called: - ANSWER>>Holiday

Checking is: - ANSWER>>a fine crack in the surface of a coating that rarely reaches
the substrate.

Inspection documentation is important because: - ANSWER>>Owners use the
documentation for a variety of purposes.

An Inspectors personal log book should contain: - ANSWER>>No comments
regarding the application team.

You have just received your NACE CIP Level 1 certification when you are asked to
supervise a team of uncertified field pipeline inspectors. Your FIRST preferred
course of action is to: - ANSWER>>Review the NACE Attestation prior to making a
decision.

Good record can provide maintenance departments with detailed information
about ALL of the following EXCEPT: - ANSWER>>How the item was coated.

Non Conformance Reports are completed by the Inspector: - ANSWER>>When
the Inspector and Contractor deem it to be significant non conforming item.

The initial steel condition is important to the NACE Inspector because: -
ANSWER>>The Inspector may have to reject the steel.

The form of corrosion that has the largest potential for unexpected catastrophic
failure is: - ANSWER>>Galvanic Corrosion

What is used to determine compressed air cleanliness? - ANSWER>>Profilometer

Osmotic blistering is most likely to occur as a result of: - ANSWER>>Airless spray
application.

, When performing tests for oil and grease using an ultra violet light, the NACE
Inspector should be aware that: - ANSWER>>Synthetic oil or grease may not be
identified.

To achieve consistently accurate results with ALL alt test equipment: -
ANSWER>>wash your hands before sampling.

When holiday testing is required the Inspector is always required to enforce what
standard? - ANSWER>>NACE SP 0188

If the specifier does not identify a restriction level in accordance with SSPC PA 2,
the default restriction level is: - ANSWER>>Level 3

Fine cracks in the surface of a coating that rarely reach the substrate are called: -
ANSWER>>Checking

It is good practice for the NACE Inspector to have instrument calibration
certificates available: - ANSWER>>At all times.

In a non convertible coating the role of the primary solvent is to: - ANSWER>>To
control the evaporation rate.

Removal of weld splatter is required: - ANSWER>>When specifically identified in
the owners specification.

Common errors that may produce inaccurate readings when using a Dial Type
Magnetic Pull Off Dry Film Thickness(DFT) gauge include: - ANSWER>>Failing to
determine the Base Metal Reading(BMR),Rotating the dial too fast when taking
measurements, and Measuring ditty, tacky, or soft films.

Conventional spray us good choice when: - ANSWER>>High quality finishes are
required.

Información del documento

Subido en
6 de marzo de 2025
Número de páginas
20
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$16.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
5
Seguidores
0
Artículos
1316
Última venta
6 meses hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes