✔✔Pressure relief devices installed in underground dispensing tanks shall be piped
vertically upward of _____ feet above the ground.
A) 11
B) 10
C) 12
D) 9 - ✔✔B) 10
✔✔No person under the age of ___ years shall be permitted to dispense propane.
A) 20
B) 21
C) 19
D) None of the Above - ✔✔D) None of the Above
Age of 18 years
✔✔Which Category License can requalify cylinders?
A) Cat I
B) Cat 2
C) Cat 3
D) Cat 4 - ✔✔A) Cat 1
✔✔A person, firm, or corporation who disconnects any container or system shall notify
the owner of the container or system within ____ hours.
A) 1
B) 12
C) 24
D) 48 - ✔✔C) 24
✔✔Vehicle fuel dispensers or dispensing stations which have been inactive ( out of
service) for a period of ____ months shall be removed from the premises.
A) 10
B) 11
C) 12
D) 24 - ✔✔C) 12 months
✔✔According to what NFPA 54 Annex can you find the methods for leak test as
incorporated by reference in rule 5J-20.002, F.A.C?
A) Annex B
B) Annex C
C) Annex L
D) None of the Above - ✔✔B) Annex C of the NFPA 54
✔✔When must you the appropriate Weights & Measures Permit?
,A) A Truck Meter (>20 gpml)
B) A Dispenser Meter (<20 gpml)
C) Scale for weighting
D) All of the Above - ✔✔D) All of the Above
✔✔Outside training (PTS, others) courses must be approved by the Department.
A) True
B) False - ✔✔A) True
✔✔Who is primarily responsible for the overseeing the operations of the licensed
location?
A) Master Qualifier
B) Qualifier
C) Owner
D) Either A or C - ✔✔A) Master Qualifier
MQ can be a owner but a owner might not be a MQ
✔✔Does Florida allow tanks to be on RV or structure roofs?
A) True
B) False - ✔✔False
✔✔Requalifiers of cylinders must have a Cat 1 license.
A) True
B) False - ✔✔A) True
✔✔Proof of insurance primary policy must cover
A) Loss of Income
B) Property Damage Liability
C) Bodily Injury Liability
D) Both B and C - ✔✔D) Both B and C
Must not be less than $1 min coverage
✔✔NFPA 58 Section 4.4 requires every employee who handles or causes propane to
be transported to have refresher training
A) Every three years.
B) Every two years.
C) Every six months.
D) Every year. - ✔✔A) Every three years.
✔✔Training records must be maintained at the business location and made available for
Bureau Inspection.
A) True
B) False - ✔✔A) True
, ✔✔The point of transfer at a dispensing unit must be ___ feet from public ways,
including pubic streets, highways, throughfares and sidewalks.
A) 15
B) 30
C) 20
D) 10 - ✔✔D) 10
✔✔Name the specification which propane containers are not manufactured under.
A) ASME
B) ICI
C) DOT
D) FAA - ✔✔B) ICI
✔✔ASME stands for - ✔✔American Society of Mechanical Engineers
✔✔DOT stands for - ✔✔US Department of Transportation
✔✔FAA stands for - ✔✔The Federal Aviation Adminstration
✔✔ICC stands for - ✔✔Interstate Commerce Commission
✔✔A licensed buiness organization that no longer possesses a duly designated qualifier
has ___________ to designate a new qualifier and avoid suspension of the license?
A) 30 days
B) 20 days
C) 24 days
D) None of the above - ✔✔B) 20 days
Chapter 527.201 (6) (a)
✔✔Immediatly upon discovery, all LP Gas licensees shall notify the department of any
LP Gas related accident involving a customer account if; Uncontrolled ignition of LP Gas
results in:
A) Death
B) Personal injury requiring medical treatment
C) Property damages exceeding $3,000 or Uncontrolled igniton resulting in $3,000 in
damage.
D) All of the Above - ✔✔D) All of the Above
✔✔LP Gas my NOT be used: As a source of pressure in lieu of compressed air or
nitrogen to operate Emergency Shut-Off valves, spray guns, or other similar equipment.
A) True
B) False - ✔✔B) True