100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4.2 TrustPilot
logo-home
Examen

NCLE PRACTICE TEST SET 2025 |GUARANTEED ACCURATE ANSWERS

Puntuación
-
Vendido
-
Páginas
48
Grado
A+
Subido en
04-03-2025
Escrito en
2024/2025

A Correct Statement regarding epithelial cells is that they: a)Comprise the posterior layer of the cornea b)Are unable to regenerate c)Comprise the thickest layer of the cornea d) Have the ability to reproduce - ACCURATE ANSWERS d) have the ability to reproduce Which of the following prescriptions indicates against-the-rule astigmatism? a)-4.50 +1.00 x75 b)-4.50 +1.00 x 180 c)-4.50 -1.00 x 165 d)4.50 -1.00 x 180 - ACCURATE ANSWERS a)-4.50 +1.00 x75 When a keratometer is being calibrated, which of the following targets will provide the most reliable result? a)the single-cut anterior surface of a high-plus lens b)a perfectly flat highly polished mirror c) a set of steell balls of known radii d)the unfinished posterior surface of a low-minus lens - ACCURATE ANSWERS c) a set of steel balls of known radii Inadequate movement of a soft lens can be corrected by using a lens that a) has a steeper base curve b)

Mostrar más Leer menos
Institución
NCLE
Grado
NCLE











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
NCLE
Grado
NCLE

Información del documento

Subido en
4 de marzo de 2025
Número de páginas
48
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NCLE PRACTICE TEST SET 2025 |
GUARANTEED ACCURATE
ANSWERS

A Correct Statement regarding epithelial cells is that they:


a)Comprise the posterior layer of the cornea
b)Are unable to regenerate
c)Comprise the thickest layer of the cornea
d) Have the ability to reproduce - ACCURATE ANSWERS✔✔ d) have
the ability to reproduce


Which of the following prescriptions indicates against-the-rule
astigmatism?


a)-4.50 +1.00 x75
b)-4.50 +1.00 x 180
c)-4.50 -1.00 x 165
d)4.50 -1.00 x 180 - ACCURATE ANSWERS✔✔ a)-4.50 +1.00 x75


When a keratometer is being calibrated, which of the following targets
will provide the most reliable result?

,a)the single-cut anterior surface of a high-plus lens
b)a perfectly flat highly polished mirror
c) a set of steell balls of known radii
d)the unfinished posterior surface of a low-minus lens - ACCURATE
ANSWERS✔✔ c) a set of steel balls of known radii


Inadequate movement of a soft lens can be corrected by using a lens that


a) has a steeper base curve
b) has a smaller diameter
c) has a larger diameter
d) has a higher water content - ACCURATE ANSWERS✔✔ b)has a
smaller diameter


A long-term, successful, hydrogel contact lens wearer suddenly develops
dry eyes. Which of the following is most likely to cause this problem?


a) Use of oxidative solution
b) use of rewetting drops
c) use of anti-histamines
d) Wearing of lenses in the wrong eyes - ACCURATE ANSWERS✔✔
c) use of anti-histamines

,During slit-lamp evaluation, on upward gaze, a patient's soft contact
lenses move 0.5 to 1mm when the patient blinks. These lenses are:


a) a good fit
b) too loose
c) too tight
d) too large - ACCURATE ANSWERS✔✔ a) a good fit


A new daily wearer of soft lenses returns for the first follow up visit with
itching, burning, injected eyes. The most likely cause of these problems
is:


a) solution reaction
b) giant-cell papillary conjunctivitis
c) a lens fit that is too loose
d) inability to wear soft lenses - ACCURATE ANSWERS✔✔ a)
solution reaction


Which of the following is the mode of slit-lamp illumination used to
view the early stages of microcystic edema?


a) Retroillumination

, b) Direct illumination
c) Parrallelpiped
d) Oscillation - ACCURATE ANSWERS✔✔ a) Retroillumination


Which of the following changes is best able to improve oxygen
transmissibility to a patient's cornea?


a) Increasing tear exchange
b) Increasing Dk
c) Increasing optical zone diameter
d) Increasing CN bevel - ACCURATE ANSWERS✔✔ b) Increasing Dk


In using fluorescein to evaluate the fit of a rigid lens of 9.0mm diameter
on a typical eye, a correct statement is that:


a) apical touch with pooling in the PPC curve area is preferred
b) apical toxicity may not be obvious
c) apical pooling with edge touch is recommended
d) apical area, mid-peripheral area, and the lens edges should be
assessed - ACCURATE ANSWERS✔✔ d) apical area, mid-peripheral
area, and the lens edges should be assessed
$15.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EXAMLINKS West Virginia University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
56
Miembro desde
1 año
Número de seguidores
6
Documentos
3397
Última venta
1 semana hace
ECONOMICS|NURSING|BIOLOGY |BUSINESS |LAW EXAMS |STUDY NOTESLATEST AND UPDATED .

On this page, you find all documents, package deals, and flashcards offered by seller EXAMLINKS.

3.1

17 reseñas

5
4
4
4
3
3
2
2
1
4

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes