100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

MACHINIST MATE EXAM LATEST EXAM QUESTIONS AND CORRECT ANSWERS (ALREADY GRADED A+) | PROFESSOR VERIFIED | LATEST VERSION 2025

Puntuación
-
Vendido
-
Páginas
41
Grado
A+
Subido en
02-03-2025
Escrito en
2024/2025

MACHINIST MATE EXAM LATEST EXAM QUESTIONS AND CORRECT ANSWERS (ALREADY GRADED A+) | PROFESSOR VERIFIED | LATEST VERSION 2025

Institución
MACHINIST MATE
Grado
MACHINIST MATE











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
MACHINIST MATE
Grado
MACHINIST MATE

Información del documento

Subido en
2 de marzo de 2025
Número de páginas
41
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

1|Page



MACHINIST MATE EXAM LATEST EXAM QUESTIONS
AND CORRECT ANSWERS (ALREADY GRADED A+) |
PROFESSOR VERIFIED | LATEST VERSION 2025
What NSTM deals with propulsion and SSTG Turbines? - (answers)NSTM 231

Whats type of rotary pump is frequently used as a lubricanting pump on pumpe
and other aux equipment? - (answers)Simple gear pimp

What is the normal length of a tapered plug? - (answers)3"

What is installed on a non-condensing turbone to protect turbine casing from
excessive pressure? - (answers)Combination exhaust relief valve 2-3 psi above
exhaust line pressure

On an SSTG, what protects turbine casing from excessive pressure? -
(answers)Back pressure trip

When starting an SSTG, what is a minimum lube oil temp? - (answers)60 degrees

What are the four sections of a PQS? - (answers)Fundamentals, systems,
watchstations, qual card

What is the number for a PMS feedback report? - (answers)4790/7B

When should oil coolers be put into operation on aux machinery? -
(answers)When temp of lube oil leaving cooler is 100 degrees

DFT is designed to operate at what pressure and temp? - (answers)15 psi and 240-
250 degrees

What is installed on a centrifugal pump to eliminate renewing of an entire
propellor and pump casing due to rapid wear? - (answers)Wearing rings

The federal water pollution control act was amended in what year? -
(answers)1970

,2|Page


What is the NSTM for compressed air systems? - (answers)551

What is the max allowable pressure drop across a fuel oil duplex strainer when
online? - (answers)3%

What is the NSTM for general reduction gear? - (answers)241

What is the NSTM for forced draft blowers? - (answers)554

What is the required amount of sodium nitrate used for a sodium nitrate wet lay
up? - (answers)10lbs per 1,000 gallons of feed water

What is the NSTM for insulation and lagging? - (answers)635

What is QA chapter 11? - (answers)QA forms and instructions

What is QA chapter 12? - (answers)Submarine preservation

What is QA chapter 13? - (answers)Wire removal and replacement

What is QA chapter 10? - (answers)Quality assurance records

What is QA chapter 9? - (answers)Audits, surveillance, evaluations and
assesments

What is QA chapter 3? - (answers)PQS and training

What is QA chapter 2? - (answers)Quality maintenance process

What is QA chapter 4? - (answers)Welder, brazer, and NDT qualifications

What is QA chapter 5? - (answers)In process control

When is the current ships maintenance project verified and updated? -
(answers)Monthly

PMS schedules are categorized in what manner? - (answers)Cycle, quarterly,

,3|Page


weekly

Main feed pump is classified as what type of pump? - (answers)Multi stage
High speed
Turbine driven

How long must the engine room/fire room operating log be kept for? - (answers)2
years

Main feed pumps are fitted with what two types of governors? - (answers)Speed
limiting
Constant speed

the number of revolutions to major speed change is entered in what column? -
(answers)3

Entries for astern pitch are preceded by what level? - (answers)B

What is the max allowable super heater outlet temp during transition periods of
15mins - 1 hour on a 1200 psig D type boiler? - (answers)1020 degrees

What is the first action taken, when you are experiencing difficulty in maintaining
boiler water level on an automated ship? - (answers)Shift boiler feed water
control to remote/manual

In the engineering bell book, what does I mean? - (answers)Ahead standard speed

In the engineering bell book, what does III mean? - (answers)Ahead flank speed

In the engineering bell book, what does B 1/3 mean? - (answers)Back 1/3 speed

In the engineering bell book, what does Z mean? - (answers)Stop

In the engineering bell book, what does BF mean? - (answers)Back full speed

In the engineering bell book, what does BEM mean? - (answers)Back emergency
speed

, 4|Page




In the engineering bell book, what does II mean? - (answers)Ahead full speed

When order received is recorded as RPM in what column? - (answers)2

What QA for is used for testing and inspection? - (answers)QA form 17

Boiler high water alarm is set to what parameter - (answers)+7 inches

During a white smoke casualty to a boiler, what must never be adjusted? -
(answers)Fuel oil header pressure

What temp is lube oil maintained on an operating main engine? - (answers)120-
130 degrees

A ruptured feed water control valve diaphragm will have what adverse effect on
boiler water level? - (answers)Water level increase
Valve will fail open

Maximum steady state superheater outlet temp on a D type 1200 psig boiler? -
(answers)1000 degrees

During loss of vacuum casualty on a main condenser, what action must be taken
when vacuum decreases to 15"? - (answers)Main engine must be stopped and
casualty procedure IAW EOCC

Temporary distortion of SSTG rotor numerous start/stop episodes is known as
what? - (answers)Bowed rotor

Whenever a propulsion turbine casing joint is opened for any reason, a final
contact check is required by taking a red and blue check of the made up joint,
what is the required contact for non pumping groove joints? - (answers)75%
contact over entire joint, 1/4" minimum continuous contact inside the groove and
across each pressure section

What is the function of staff packing on SSTG - (answers)Prevent leakage of stem
from ingress of air into turbines
Gratis
Accede al documento completo:
Descarga

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
Nelly003

Conoce al vendedor

Seller avatar
Nelly003 Teachme2-tutor
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
303
Miembro desde
1 año
Número de seguidores
2
Documentos
3052
Última venta
7 horas hace

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes