2024/2025 TFM Test 12 [Fire Alarm Technical] Exam With Questions & Accurate Answers 1 Does a fire hood system and a kitchen need to be monitored by the fire alarm system? Yes 2. What does P.L.F.A stand for what? Power-Limited Fire Alarm 3. What does N.P.L.F.A stand for what? Non-Power Limited Fire Alarm 4. What is the difference between P.F.L.A and N.P.F.L.A? an N.P.L.F.A can operate at up to 600v, and the power output isn't limited a P.L.F.A has the voltage and power limited by a listed power source . 5. What material must N.P.F.L.A circuit conductors be made from? ONLY solid stranded copper is permitted. 6. What does A.W.G. stand for? American Wire Gauge 7. What size conductors are permitted? Size 18 A.W.G and 16 A.W.G are permitted, provided they do not exceed certain capacities. 8. What is used to protect transformers or other devices supplied from power-supply conductors? An over-current device not rated over 20 amperes. 9. a] When located within 7 feet of the floor, how shall cables be fastened? Cables shall be fastened in an approved manner at intervals of not more than 18 inches. b ] Single conductors shall not be smaller than ? ___ A.W.G. 18 10. Conductors of 28 A.W.G shall only be permitted in which circumstance? Spliced with a connector listed as suitable for 26 to 24 A.W.G 11. How shall P.F.L.A conductors NOT be installed? P.F.L.A. conductors shall not be strapped, taped, or attached to the exterior of any conduit or raceway. 12. What is Plenum cable? Cable that can be installed in ducts, plenums, or other spaces used for environmental air. 13. What is a Riser cable? Cable to be used in vertical wire runs in shafts between floors. Not to be used where Plenum cable is required. It is capable of preventing fire from rising from floor to floor . 14. What is a general-purpose cable? Cable for general-purpose fire alarm use. Not to be used where plenum cable or riser cable is required. It is resistant to the spread of fire . 15. Why 'type' shall plenum cable be? What substitutions are allowed? Power Limited Fire Alarm Plenum (F.P.L.P) C.M.P can be substituted. 16. Why 'type' shall riser cable be? What substitutions are allowed? Power Limited Fire Alarm Riser (F.P.L.R) C.M.P, F.P.L.P. C.M.R. can be substituted. 17. What 'type' shall general-purpose wire be? What substitutions are permitted? Power Limited Fire Alarm (F.P.L) C.M.P, F.P.L.P, C.M.R, F.P.L.R, C.M.G CM can be substituted (all types ) 18. What is the maximum voltage permitted through multi-conductor N.P.F.L.A. cables? 150 volts 19. What is the voltage rating marked on PFLA cables? Not less than 300 volts 20. Shall the voltage rating be marked on PFLA cables? No, because they may be mistakenly used for electrical applications. 21. What is 'Rate Compensation Detector'? A device that responds when a temperature rises at an exceeding rate that is predetermined. 22. What is a 'Smoke Detector'? A device that detects both visible and invisible combustion particles 23. Which detector is best for detecting invisible particles? Ionization 24. Which sensor is better at detecting thick, visible smoke particles? Photoelectric 25. What is a SPOT TYPE sensor? A device for detecting an element that is concentrated at a particular location. 26. What is a DIGITAL ALARM COMMUNICATOR TRANSMITTER (D.A.C.T.)? A system component at the protected premises is connected to the detection devices. It has a line seizure and can connect to a D.A.C.R. 27. What is a DIGITAL ALARM COMMUNICATOR RECEIVER? (D.A.C.R)? A system component that accepts and displays signals sent over the public phone network from a D.A.C.T (i.e A.D.T monitoring center) 28. What is an alarm signal? A signal indicating an emergency that requires immediate action. 29. What is a Supervisory signal? A signal that indicates the need for action in connection with the SUPERVISION of fire equipment. 30. What is a Trouble signal? A signal that indicates a fault with the fire equipment. It must have an audible signal, distinctive from alarm signals . 31. Does an exterior sprinkler system need to be supervised? Yes What is a Cloud Chamber Smoke Detection? A detector draws an air sample into a high humidity, low pressure chamber. The conditions in the chamber cause the moisture in the air to condense on the smoke particles, forming a cloud. The density of this cloud is measured by a photoelectric principle, if it meets certain criteria, an alarm is generated .

Mostrar más Leer menos
Institución
TFM 12
Grado
TFM 12









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
TFM 12
Grado
TFM 12

Información del documento

Subido en
28 de febrero de 2025
Número de páginas
9
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

‭ 024/2025 TFM Test 12 [Fire Alarm‬
2
‭Technical] Exam‬‭With Questions &‬
‭Accurate Answers‬

‭ Does a fire hood system and a kitchen need to be monitored by the fire alarm system?‬
1
‭Yes‬

‭ . What does P.L.F.A stand for what?‬
2
‭Power-Limited Fire Alarm‬

‭ . What does N.P.L.F.A stand for what?‬
3
‭Non-Power Limited Fire Alarm‬

‭ . What is the difference between P.F.L.A and N.P.F.L.A?‬
4
‭an N.P.L.F.A can operate at up to 600v, and the power output isn't limited‬
‭a P.L.F.A has the voltage and power limited by a listed power source‬‭.‬

‭ . What material must N.P.F.L.A circuit conductors be made from?‬
5
‭ONLY solid stranded copper is permitted.‬

‭ . What does A.W.G. stand for?‬
6
‭American Wire Gauge‬

‭ . What size conductors are permitted?‬
7
‭Size 18 A.W.G and 16 A.W.G are permitted, provided they do not exceed certain capacities.‬

‭ . What is used to protect transformers or other devices supplied from power-supply‬
8
‭conductors?‬
‭An over-current device not rated over 20 amperes.‬

‭ . a] When located within 7 feet of the floor, how shall cables be fastened?‬
9
‭Cables shall be fastened in an approved manner at intervals of not more than 18 inches.‬

‭b ] Single conductors shall not be smaller than ? ___ A.W.G.‬
‭ 8‬
1

‭10. Conductors of 28 A.W.G shall only be permitted in which circumstance?‬

, ‭Spliced with a connector listed as suitable for 26 to 24 A.W.G‬

‭ 1. How shall P.F.L.A conductors NOT be installed?‬
1
‭P.F.L.A. conductors shall not be strapped, taped, or attached to the exterior of any conduit or‬
‭raceway.‬
‭12. What is Plenum cable?‬
‭Cable that can be installed in ducts, plenums, or other spaces used for environmental air.‬

‭ 3. What is a Riser cable?‬
1
‭Cable to be used in vertical wire runs in shafts between floors. Not to be used where Plenum‬
‭cable is required.‬
‭It is capable of preventing fire from rising from floor to floor‬‭.‬

‭ 4. What is a general-purpose cable?‬
1
‭Cable for general-purpose fire alarm use. Not to be used where plenum cable or riser cable is‬
‭required.‬
‭It is resistant to the spread of fire‬‭.‬

‭ 5. Why 'type' shall plenum cable be? What substitutions are allowed?‬
1
‭Power Limited Fire Alarm Plenum (F.P.L.P) C.M.P can be substituted.‬

‭ 6. Why 'type' shall riser cable be? What substitutions are allowed?‬
1
‭Power Limited Fire Alarm Riser (F.P.L.R) C.M.P, F.P.L.P.‬
‭C.M.R. can be substituted.‬

‭ 7. What 'type' shall general-purpose wire be? What substitutions are permitted?‬
1
‭Power Limited Fire Alarm (F.P.L) C.M.P, F.P.L.P, C.M.R, F.P.L.R, C.M.G‬
‭CM can be substituted (all types‬‭)‬

‭ 8. What is the maximum voltage permitted through multi-conductor N.P.F.L.A. cables?‬
1
‭150 volts‬

‭ 9. What is the voltage rating marked on PFLA cables?‬
1
‭Not less than 300 volts‬

‭ 0. Shall the voltage rating be marked on PFLA cables?‬
2
‭No, because they may be mistakenly used for electrical applications.‬

‭ 1. What is 'Rate Compensation Detector'?‬
2
‭A device that responds when a temperature rises at an exceeding rate that is predetermined.‬

‭ 2. What is a 'Smoke Detector'?‬
2
‭A device that detects both visible and invisible combustion particles‬
$9.98
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
ProfJohnDutton
5.0
(1)

Documento también disponible en un lote

Conoce al vendedor

Seller avatar
ProfJohnDutton MARRYVILLE UNIVERSITY OF ST LOUIS MISSOURI
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
2
Miembro desde
1 año
Número de seguidores
0
Documentos
621
Última venta
5 meses hace
EXAMS FLASHCARDS,STUDY SETS,QUIZZES ....YOU NAME IT!!!! BY YOUR PROFESSIONAL TUTOR

Home of all study & revision Materials. Explore excellent RETAKES ASSIGNMENTS CATS TESTS EXAMS and authentic solutions for your academic challenges email me or REVIEW For Any Inquiries 24/7

5.0

1 reseñas

5
1
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes