Example of nonspecular reflector - Accurate ......red blood cells What happens to spatial pulse length when frequency increases? - Accurate ......decreases Axial resolution is dependent on? - Accurate ......wavelength Lateral resolution is dependent on? - Accurate ......beam diameter Where does the beam of an unfocused transducer diverge? - Accurate ......Fraunhofer zone Reverberation artifacts are a result of - Accurate ......two or more strong reflecting surfaces True/False: Grating lobes are essential for the proper operation of a linear phased array. - Accurate ......False True/False: Electronically steered scanners always produce higher resolution images than do mechanically steered scanners. - Accurate ......False True/False: An annular array scanner uses mechanical beam steering. - Accurate ......True True/False: A linear sequenced array cannot be dynamically focused. - Accurate ......False Registration or B-mode alignment - Accurate ......Which AIUM test object function utilizes all the groups of wires in the AIUM 100 mm test object? Axial resolution - Accurate ......W

Mostrar más Leer menos
Institución
ARDMS SPI
Grado
ARDMS SPI











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ARDMS SPI
Grado
ARDMS SPI

Información del documento

Subido en
27 de febrero de 2025
Número de páginas
84
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ARDMS SPI EXAM QUESTIONS
(LATEST UPDATE 2025) |
GUARANTEED ACCURATE
ANSWERS |PASS!!

Example of nonspecular reflector - Accurate ✔✔✔ ......red blood cells


What happens to spatial pulse length when frequency increases? -
Accurate ✔✔✔ ......decreases


Axial resolution is dependent on? - Accurate ✔✔✔ ......wavelength


Lateral resolution is dependent on? - Accurate ✔✔✔ ......beam diameter


Where does the beam of an unfocused transducer diverge? - Accurate
✔✔✔ ......Fraunhofer zone


Reverberation artifacts are a result of - Accurate ✔✔✔ ......two or more
strong reflecting surfaces


True/False: Grating lobes are essential for the proper operation of a
linear phased array. - Accurate ✔✔✔ ......False

,True/False: Electronically steered scanners always produce higher
resolution images than do mechanically steered scanners. - Accurate
✔✔✔ ......False


True/False: An annular array scanner uses mechanical beam steering. -
Accurate ✔✔✔ ......True


True/False: A linear sequenced array cannot be dynamically focused. -
Accurate ✔✔✔ ......False


Registration or B-mode alignment - Accurate ✔✔✔ ......Which AIUM
test object function utilizes all the groups of wires in the AIUM 100 mm
test object?


Axial resolution - Accurate ✔✔✔ ......Which AIUM test object function
utilizes the A group of wires in the AIUM 100 mm test object?


Lateral resolution - Accurate ✔✔✔ ......Which AIUM test object
function utilizes the B group of wires in the AIUM 100 mm test object?


Dead zone - Accurate ✔✔✔ ......Which AIUM test object function
utilizes the D group of wires in the AIUM 100 mm test object?

,Depth calibration - Accurate ✔✔✔ ......Which AIUM test object
function utilizes the C or E groups of wires in the AIUM 100 mm test
object?


What happens to axial resolution when spatial pulse length is decreased?
- Accurate ✔✔✔ ......improves


How much will a 3.5 mhz pulse be attenuated after passing through 2 cm
of soft tissue? - Accurate ✔✔✔ ......3.5 db


Propagation speed errors result in - Accurate ✔✔✔ ......improper axial
position


Enhancement is caused by - Accurate ✔✔✔ ......weakly attenuating
structures


The Doppler shift frequency is - Accurate ✔✔✔ ......directly
proportional to the velocity of the reflector


The number of frames per second necessary for a real-time image to be
flicker free is - Accurate ✔✔✔ ......more than 15


True/False: The SPTA intensity will always be larger than the SATA
intensity. - Accurate ✔✔✔ ......True

, The intensity of the ultrasound beam is usually greater at the focal zone
because of - Accurate ✔✔✔ ......the smaller beam diameter


If the amplitude is doubled, the intensity is - Accurate
✔✔✔ ......quadrupled


The attenuation for soft tissue is - Accurate ✔✔✔ ......increased with
tissue thickness


The acoustic impedance of the matching layer - Accurate ✔✔✔ ......can
be chosen to improve transmission into the body


True/False: In a pulse-echo system, the quality factor should be made as
large as possible. - Accurate ✔✔✔ ......False


True/False: The beam diameter is constant in the near zone. - Accurate
✔✔✔ ......False


The operating frequency is dependent on - Accurate ✔✔✔ ......thickness
of the crystal


The period of an ultrasound wave is - Accurate ✔✔✔ ......the time of
one wavelength
$16.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EXAMLINKS West Virginia University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
54
Miembro desde
1 año
Número de seguidores
6
Documentos
3392
Última venta
4 días hace
ECONOMICS|NURSING|BIOLOGY |BUSINESS |LAW EXAMS |STUDY NOTESLATEST AND UPDATED .

On this page, you find all documents, package deals, and flashcards offered by seller EXAMLINKS.

3.0

16 reseñas

5
3
4
4
3
3
2
2
1
4

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes