40 Hour Property and Building Inspection Module 1 Site Conditions with Complete Solutions

Institución
40 Hour Property And Building Inspection
Grado
40 Hour Property and Building Inspection









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
40 Hour Property and Building Inspection
Grado
40 Hour Property and Building Inspection

Información del documento

Subido en
26 de febrero de 2025
Número de páginas
15
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

40 Hour Property and Building
Inspection Module 1 Site Conditions with
Complete Solutions
______________ are exterior structures that project from the building structure at least
one story above grade - ANSWER-balcony

a balcony can be supported by columns and the house wall - ANSWER-true

A difference between a gas range and an electric range is that electric ranges_______.
- ANSWER-Require a 240-volt electrical supply

a guideline for the appropriate slope of a lot away from a house is - ANSWER-six inches
over ten feet

a low depression used in the soil for drainage - ANSWER-Swale

A masonry chimney serving a wood fireplace should be at least _______. - ANSWER-
12 feet

a maximum rise for steps is commonly _______ inches - ANSWER-7 3/4

A notch cut in the bottom edge of a beam is more likely to result in failure then one cut
in the top edge, although as a general rule, notches and holes should not be cut in
beams. - ANSWER-True

A plug-in cord serving a built-in dishwasher must be - ANSWER-Between 36 and 48
inches in length.

A popular bathroom countertop that is not used in the kitchen is cultured marble -
ANSWER-True

A reliable _____ connection for purposes of a smart home is usually defined as a high-
speed _____ connection. - ANSWER-Internet, broadband

A smart home is one that is equipped with network- connected products? - ANSWER-
True

a vapor retarder is designed to restrict vapor diffusion - ANSWER-true

A wood sill is typically used to connect the top of the foundation to the wood floor
system above. - ANSWER-True

, Absence of kick out flashing is a reportable defect regardless of the age of the house. -
ANSWER-True

All are included in the inspection of a microwave oven EXCEPT - ANSWER-Check for
radiation

All modern food waste disposers: - ANSWER-are of the continuous feed or batch type

All of the following are basic components of a masonry wood-burning fireplace EXCEPT
- ANSWER-a heat circulator

All of the following are common problems with masonry chimneys EXCEPT - ANSWER-
Not continuous through roof

All of the following are common problems with walks and driveways EXCEPT -
ANSWER-control joints

All of the following could indicate spreading rafters EXCEPT - ANSWER-Cracks in
interior ceilings running perpendicular to the outside wall

All residences must have at least one exit that is a: - ANSWER-side hinged door

an inspector can think of purlins as small beams that run under the midpoint of all
rafters - ANSWER-true

an inspector should check for the presence and proper operation of the door release
catch and pull cord, intended to allow quick, _______ of the door from the mechanized
traveler in the event of power failterm-5ure, malfunction, or emergency. - ANSWER-
manual operation

An inspector should not walk on a roof if? - ANSWER-If it could cause damage or is
unsafe

Asbestos cement shingles should be removed from homes. - ANSWER-False

At the top and bottom edges of sheathing, support may be provided by ______ clips. -
ANSWER-H clips

Automatic motorized garage door operators are required to: - ANSWER-Reverse
direction automatically if there is an obstruction in the path of a closing door. & Be at
least 1/3 horsepower when used with 16 foot doors (A and B)

Automatic motorized garage operators must be checked for _______ and proper
operation. - ANSWER-secure mounting

B vents are typically used for what fuels - ANSWER-Natural gas and propane
$12.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
LUCKYSTAR2022 West Virginia University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
904
Miembro desde
3 año
Número de seguidores
724
Documentos
9621
Última venta
1 semana hace
LUCKYSTAR2022

Hi there well come to luckystar2022. Here you will find guaranteed quality solution for Nursing and any other Accademic related notes, exams, study guides, cases and many more. 100% value for your time and money. GOOD LUCK

3.5

155 reseñas

5
62
4
25
3
25
2
8
1
35

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes