100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

U3 ICC Tank Tightness Testing Exam QUESTIONS WITH COMPLETE 100% VERIFIED SOLUTIONS 2024/2025

Puntuación
-
Vendido
-
Páginas
10
Grado
A+
Subido en
23-02-2025
Escrito en
2024/2025

U3 ICC Tank Tightness Testing Exam QUESTIONS WITH COMPLETE 100% VERIFIED SOLUTIONS 2024/2025

Institución
Grado









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Grado

Información del documento

Subido en
23 de febrero de 2025
Número de páginas
10
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

U3 ICC Tank Tightness Testing Exam QUESTIONS
WITH COMPLETE 100% VERIFIED SOLUTIONS
2024/2025
On a steel tank without cathodic protection, if a coating is flawed, what happens at the
flaw?
a. Cathodic surface is increased
b. Current flow is increased from this area
c. Current flow is increased to this area - Answer - b. Current flow is increased from this
area

On an impressed current cathodic protection system, the negative wire of the rectifier is
connected to the:
a. Anode
b. Cathode
c. Drop tube
d. Dielectric union - Answer - b. Cathode

All are examples of acceptable release detection for tanks, except:
a. Impressed current cathodic protection
b. Automatic tank gauging
c. Statistical inventory reconciliation
d. Soil-vapor monitoring - Answer - a. Impressed current cathodic protection

When a tank is temporarily closed, the cathodic protection system:
a. Must be turned off
b. Must remain in operation
c. Should be removed
d. Operator can have it on or off. - Answer - b. Must remain in operation

When a steel tank is installed with a galvanic CP system attached, the tank gauges are
usually connected through a riser with a dielectric bushing. What is the purpose of that?
a. To prevent static discharge
b. To minimize effects of noise
c. To electrically isolate the tank from the tank gauge
d. To prevent water intrusion in the tank - Answer - c. To electrically isolate the tank
from the tank gauge

Factory-installed diectric coatings may include all of the following except:

, a . Asphalt
b. epoxies
c. Enamels
d. fiberglass-reinforced plastic - Answer - a . Asphalt

According to the EPA, Tank tightness test data must be maintained for:
a. 18 months
b. 3 years
c. 5 years
d. Until the next test is performed - Answer - d. Until the next test is performed

How long must records of UST system repairs be available on site?
a. 60 days
b. 1 year
c. 5 years
d. for the remaining lifetime of the UST system - Answer - d. for the remaining lifetime
of the UST system

In the event of a release, what is the reporting requirement?
a. ICC licensed supervisor must report the leak within 24 hours
b. Owner/Operator must report the leak within 24 hours
c. Owner/Operator must report the leak within 18 hours
d. ICC licensed supervisor must report the leak within 18 hours - Answer - b.
Owner/Operator must report the leak within 24 hours

At what size spill does it need to be reported?
a. 5 gallons
b. 10 gallons
c. 15 gallons
d. 25 gallons - Answer - d. 25 gallons

Contamination of soils is encountered before removing a tank. The clean up must be
initiated by the:
a. Fire Marshal
b. Ecology inspector
c. Owner / operator of the UST system
d. Landlord - Answer - c. Owner / operator of the UST system

All are examples of overfill protection, except:
a. Vent restricting device
$9.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
mkhenris

Conoce al vendedor

Seller avatar
mkhenris Self
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1
Miembro desde
1 año
Número de seguidores
0
Documentos
13
Última venta
6 meses hace
Lecthenris

EXCELSIOR! Am dedicated with a passion for helping students succeed, I specialize in providing high-quality study resources on STUVIA including ATI modules and other essential certifications, earning excellent ratings and a stellar reputation for boosting students' grades. My commitment to excellence

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes