What action below would be most in keeping with the ALARA principle while performing a diagnostic ultrasound examination? A: Allow multiple students to scan an obstetrical patient because the fetus is in a good position for imaging. B: Prolong the sonogram to make videos of the fetus for each family member. C: Complete the diagnostic scan in a timely fashion at the lowest output power that achieves a quality image. D: Maximize the acoustic output to brighten the overall image. E: Extend the sonogram beyond the intended scope of the exam requisition. C: Complete the diagnostic scan in a timely fashion at the lowest output power that achieves a quality image. What does the ALARA principle stand for? As Low As Reasonable Achievable

Mostrar más Leer menos
Institución
SPI
Grado
SPI

Vista previa del contenido

K
C
LO
YC
DAVIES SPI REVIEW EXAM
D

PREP QUESTIONS AND
U


CORRECT VERIFIED
ST




ANSWERS 100% GUARANTEED
PASS A+ GRADE

,What action below would be most in keeping with the ALARA principle while performing a
diagnostic ultrasound examination?
A: Allow multiple students to scan an obstetrical patient because the fetus is in a good position
for imaging.
B: Prolong the sonogram to make videos of the fetus for each family member.
C: Complete the diagnostic scan in a timely fashion at the lowest output power that achieves a
quality image.
D: Maximize the acoustic output to brighten the overall image.
E: Extend the sonogram beyond the intended scope of the exam requisition.
C: Complete the diagnostic scan in a timely fashion at the lowest output power that achieves a




K
quality image.




C
What does the ALARA principle stand for?
As Low As Reasonable Achievable




LO
During performance of an obstetrical ultrasound exam you adjust the system parameters to
improve the image. Which of the following parameters would increase acoustic exposure?
A: Increase gain
B: Increase TGC
YC
C: Increase frequency
D: Increase transmit power
E: Increase frame averaging
D: Increase transmit power
D

While performing a sonogram to minimize risk to the fetus which imaging mode trade off would
be most applicable?
A: Use M-mode instead of pulsed-wave Doppler to measure the fetal heart rate.
U


B: Use color Doppler instead of power Doppler to image the umbilical cord.
C: Use pulsed-wave Doppler instead of power Doppler to evaluate the fetal heart.
D: Use harmonics instead of fundamental to image the fetal spine.
ST




E: All of the above.
A: Use M-mode instead of pulsed-wave Doppler to measure the fetal heart rate.


Gain, TGC, and frame averaging do not affect _______ and therefore do not affect _______.
-Sound transmission
-Exposure


T or F: Increasing frequency does not increase exposure.
True

,What potential bioeffect occurs through absorption of sound energy by tissue?
A: Cavitation
B: Heating
C: Attenuation
D: Reflection
E: Refraction
B: Heating




K
When practicing universal precautions you should do all of the following EXCEPT:
A: Wear gloves when there is a potential for contact with patient bodily fluids.




C
B: Change gloves when moving from one patient to another.
C: Wash hands immediately after gloves are removed.
D: Wear face masks or eye protection whenever there is a possibility of blood splashing into




LO
your face.
E: Wash gloves between exams for re-use from one patient to another.
E: Wash gloves between exams for RE-use from one patient to another.
YC
A nosocomial infection is defined as one that is:
A: Resistant to antibiotics
B: Restricted to the respiratory system
C: Hospital-acquired
D: Not contagious
E: Requires isolation
D

C: Hospital-acquired
U


Thermally induced biological effects should be preventable by avoiding a local tissue
temperature increase exceeding:
A: 1 degree C
ST




B: 4 degrees C
C: 10 degrees C
D: 95 degrees F
E: None; thermal effects have no threshold.
A: 1 degree C


Which intensity descriptor has the lowest numerical value for the characterization of a
pulsed-wave ultrasonic field?
A: SATA
B: SPTA

, C: SATP
D: SPTP
E: These intensity descriptors are only used for continuous-wave ultrasound.
A: SATA


Increased tissue heating could occur when you:
A: Decrease frequency.
B: Increase transmit power.
C: Decrease exposure time.




K
D: Decrease pulse repetition frequency.
E: All of the above
B: Increase transmit power.




C
A study designed to determine if there is an association between an adverse effect in a




LO
population and exposure to a particular agent is a(n):
A: Case report
B: Epidemiological study
C: In vitro study
D: In vivo study
YC
E: Single-incident investigation
B: Epidemiological study


Which of the following actions is NOT compliant with HIPAA?
A: Cropping all patient identifiers from images used for teaching purposes.
D

B: Refraining from disclosing patient health information without proper authorization.
C: Reviewing your neighbors medical studies on your hospital PACS system so you can give
her your opinion of her condition.
U


D: Covering your daily requisition list so that the names are not visible to patients and visitors.
E: All of these actions are compliant with HIPAA.
C: Reviewing your neighbors medical studies on your hospital PACS system so you can give
ST




her your opinion of her condition.


What does HIPAA stand for?
The Health Insurance Portability and Accountability Act


What does mechanical index indicate on an ultrasound system?
A: The maximum temperature increase in tissue
B: The minimum temperature increase in tissue
C: Acoustic power in milliwatts

Escuela, estudio y materia

Institución
SPI
Grado
SPI

Información del documento

Subido en
19 de febrero de 2025
Número de páginas
249
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$16.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Studyclock Ashford University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
881
Miembro desde
4 año
Número de seguidores
492
Documentos
8808
Última venta
1 día hace

4.2

232 reseñas

5
130
4
45
3
34
2
10
1
13

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes