Absorption field lengths are determined - Answer by the # of bedrooms in a home or estimated gallon per day water usage Absorption field depths are determined by - Answer the soil conditions on the property From wells to springs - Answer a minimum of 50' from septic tanks and a minimum of 100' from absorption fields From property lines served by the public - Answer a minimum of 10' from septic tanks and a minimum of 5' from the absorption fields From property lines served by individual - Answer absorption lines must be 50' from adjacent property unless development is preplanned From bodies of water or impoundments - Answer minimum of 25' from septic tanks and min 50' from absorption fields From streams or tributaries - Answer a min of 25' from septic tanks and a min of 50' from absorption fields From ponded wetlands - Answer a minimum of 50' for absorption fields Building with a basement - Answer septic tank and absorption fields a minimum of 10' from foundation From a drainage ditch, trash pits, and embankments - Answer 15 feet

Mostrar más Leer menos
Institución
OSSF DR
Grado
OSSF DR









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
OSSF DR
Grado
OSSF DR

Información del documento

Subido en
19 de febrero de 2025
Número de páginas
5
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

On-Site Sewage Contractor Exam Final
Exam And Correct Answers.

Absorption field lengths are determined - Answer by the # of bedrooms in a home or estimated gallon
per day water usage



Absorption field depths are determined by - Answer the soil conditions on the property



From wells to springs - Answer a minimum of 50' from septic tanks and a minimum of 100' from
absorption fields



From property lines served by the public - Answer a minimum of 10' from septic tanks and a minimum
of 5' from the absorption fields



From property lines served by individual - Answer absorption lines must be 50' from adjacent property
unless development is preplanned



From bodies of water or impoundments - Answer minimum of 25' from septic tanks and min 50' from
absorption fields



From streams or tributaries - Answer a min of 25' from septic tanks and a min of 50' from absorption
fields



From ponded wetlands - Answer a minimum of 50' for absorption fields



Building with a basement - Answer septic tank and absorption fields a minimum of 10' from foundation



From a drainage ditch, trash pits, and embankments - Answer 15 feet

, If the water supply crosses or comes within 10 feet of the absorption field - Answer the water supply
line shall be installed at least 12 inches above the top of the aggregate layer of the absorption field line
and shall be encased in single-length larger diameter



After the permit has been issued - Answer any grading, filling or other site modifications that would
adversely affect the system will render the permit void



the first component of an on-site sewage management system - Answer the septic tank



Septic tanks are generally pre-cast with - Answer concrete and delivered to the site. They can also be
poured in place when necessary



Septic tanks must have 2 compartments with the first - Answer designed to contain at least 2/3 of the
total liquid capacity of the tank



Septic tanks may be constructed from material of than concrete only when - Answer approved by the
department's technical review committee



Regardless of the tank construction the minimum liquid capacity of a septic tank for one, two, three or
four bedroom homes - Answer shall not be less than 1,000 gallon



For each additional bedroom over 4 - Answer the septic tank capacity shall increase by 250 gallons



When garbage grinders are used - Answer septic tank capacity shall be increased by 50%



The primary purpose of a septic tank is to - Answer provide a means of settling out solid matter from
the liquid



By design the outlet of a septic tank should be - Answer two inches lower than the inlet



Once installed, the tank should have a - Answer minimum of 6 inches of cover
$10.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TestSolver9 Webster University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
760
Miembro desde
2 año
Número de seguidores
126
Documentos
25261
Última venta
2 horas hace
TESTSOLVER9 STORE

TOPNOTCH IN LEARNING MATERIALS,(EXAMS,STUDYGUIDES NOTES ,REVIEWS,FLASHCARDS ,ALL SOLVED AND PACKAGED.OUR STORE MAKE YOUR EDUCATION JOURNEY EFFICIENT AND EASY.WE ARE HERE FOR YOU FEEL FREE TO REACH US OUT .

3.6

136 reseñas

5
61
4
19
3
22
2
10
1
24

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes