FDNY Z51 RMO
The efficiency of the refrigerant cycle is affected by the operation of the condenser. Of the
following, a more efficient centrifugal compressor operation results from - ANS-lowering the
condenser pressure

In most semi hermetic compressors, the suction vapor is used for - ANS-cools the motor

The amount of refrigerant that flows through the orifices of an economizer is determined by the -
ANS-difference between the high side and the low side pressure

the installation of an inline refrigerant cleaning system is advisable - ANS-to remove impurities
from the system

a refrigerant engineer verifies that a condenser pump is cavitation of the following the most
likely cause for this condition is: - ANS-a faulty cooling tower water level controller

when an expansion valve is operating properly, at the end of the evaporator will contain -
ANS-only superheated vapor

a centrifugal water pump is considered to be fully primed when - ANS-the pump is full of liquid

A refrigeration compressor has failed to turn on. the engineer on duty verifies the electrical
circuit to the motor, including all switches and circuit breakers is complete, according to
recommended service practice, the next item to be checked would likely be the: -
ANS-temperature and pressure controls

Refrigerants are characterized by their physical properties including Flashpoint, refrigeration
effect and others, of the refrigerants in commercial and industrial the highest latent heat and
refrigerant effect is: - ANS-ammonia

which of the following ashrae refrigerant safety classification is the most toxic - ANS-b3

which of the following ashrae refrigerant safety classification is the most flammable - ANS-a3

in q indirect refrigeration system,of the following, the one that would not be used as a cooling
medium for building spaces being cooled is - ANS-r 22 (cooling medium= glycol or any brine
solution)

the primary way of achieving capacity control of a an centrifugal compressor is by: -
ANS-adjustment to the inlet impeller pre rotation vanes

, regarding the functioning of a steam turbine, why is it advisable to keep moisture in the inlet low
as possible - ANS-keeps turbine blades wear to minimum

a water chiller is equipped with a reciprocating compressor, a thermostatic expansion valve and
a an air cooled condenser. A restriction in the refrigerant line would result in - ANS-high suction
super heat

the process by which refrigerant is extracted and cleaned for reuse without requirements for
reclamation is called - ANS-recycle

the purpose of wear rings in a centrifugal pump is to - ANS-prevent wearing of the pump
housing and impeller

a centrifugal compressor is in operation with suction pressure is 3 psig and the discharge is
10psi what is the atmospheric pressure is 14.7 which is the ratio closest to - ANS-1.39

electrical current us measured in - ANS-amperage

how would you put an additional pump online - ANS-open suction valve, open discharge valve
gradually

of the following, the major advantage of a shell and coil condenser is - ANS-there is less
danger of developing leaks

an engineer needs to vary the flow of refrigerant in a refrigeration system, which operation in the
flow of the system does not include - ANS-solenoid valve

a thermal bull is attached to the suction plate between the evaporator cokl and the compressor
by an insulated line. assume that the machine room is 85 deg f . break down of the insulation
results in: - ANS-flood the evaporator

water and moisture is serious problem in a refrigerant system how to avoid - ANS-proper
evaluation at the charging of the system

while on duty a refrigeration engineer notice That the suction line to the compressor and part of
the compressor itself is frosted over the following the most likely reason for this condition would
be - ANS-There is not enough Refrigerant in the system

While doing a routine inspection the engineer notices the bulb of the TXV on the floor. The
refrigerant engineer should have attached a bulb at the - ANS-The outlet end of the coil

A refrigerant engineer verifies that a chilled water pump is cavity to of the following the most
likely cause for this condition is - ANS-Water leaks through the mechanical seals

Información del documento

Subido en
14 de febrero de 2025
Número de páginas
8
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$12.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
12
Seguidores
2
Artículos
1260
Última venta
8 meses hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes